Log:
Évaluations - 1, GPA: 4 ( )

Instructions Follett, Modèle MCC400A/W

Fabricant : Follett
Taille : 1.97 mb
Nom Fichier :
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


The icemaker will begin to produce ice and continue to produce ice until the bin level control in the ice dispenser is satisfied. The PWR, B-E, DR, C and WTR LEDs are all on. RED WTR B-E B-T 2ND 60M 20M C POWER DR WHITE BLACK YELLOW WHITE 4 3 2 T.O.L. START RUN GEARMOTOR COMPRESSOR R POTENTIAL START RELAY RUN CAP. CAPACITOR START C S 2 1 5 T.O.L. L1 L2 COMP FAN DRV WATER SENSOR G GREEN/YELLOW GRN IN ELEC BOX BROWN BLUE WHITE WHITE BLACK BLACK ORANGE RED BLACK BLACK BLACK BLACK VIOLETVIOLETWHITEBLACKREDRED BLUE BLACK FAN M ORANGE BLACK L N HIGH PRESSURE SAFETY SWITCH COMPRESSOR SWITCH BIN T-STAT BIN SIGNAL SWITCH DISPENSER Normal operation – Stage 4 Once the ice level control opens, the B-E LED goes out. After a 10 second delay the compressor LED (C), compressor and fan motor go off. (Should the ice level control not remain open for 10 seconds, the icemaker will continue to run.) The gearmotor continues to run and the DR LED remains on for 60 seconds. The purpose of this function is to drive the remaining ice out of the evaporator and to boil off any refrigerant remaining in the evaporator. The bin timer LED (BT) comes on, starting the twenty minute off cycle time delay. RED WTR B-E B-T 2ND 60M 20M C POWER DR WHITE BLACK YELLOW WHITE 4 3 2 T.O.L. START RUN GEARMOTOR COMPRESSOR R POTENTIAL START RELAY RUN CAP. CAPACITOR START C S 2 1 5 T.O.L. L1 L2 COMP FAN DRV WATER SENSOR G GREEN/YELLOW GRN IN ELEC BOX BROWN BLUE WHITE WHITE BLACK BLACK ORANGE RED BLACK BLACK BLACK BLACK VIOLETVIOLETWHITEBLACKREDRED BLUEBLACK FAN M ORANGE BLACK L N HIGH PRESSURE SAFETY SWITCH COMPRESSOR SWITCH BIN T-STAT BIN SIGNAL SWITCH DISPENSER Normal operation – Stage 5 The drive motor now shuts down and the DR LED is off. The B-T LED remains on for 20 minutes. The icemaker will not start while the B-T LED is on. To restart the icemaker for troubleshooting purposes, depress the reset button to clear the control board. RED WTR B-E B-T 2ND 60M 20M C POWER DR WHITE BLACK YELLOW WHITE 4 3 2 T.O.L. START RUN GEARMOTOR COMPRESSOR R POTENTIAL START RELAY RUN CAP. CAPACITOR START C S 2 1 5 T.O.L. L1 L2 COMP FAN DRV WATER SENSOR G GREEN/YELLOW GRN IN ELEC BOX BROWN BLUE WHITE WHITE BLACK BLACK ORANGE RED BLACK BLACK BLACK BLACK VIOLETVIOLETWHITEBLACKREDRED BLUE BLACK FAN M ORANGE BLACK L N HIGH PRESSURE SAFETY SWITCH COMPRESSOR SWITCH BIN T-STAT BIN SIGNAL SWITCH DISPENSER 24 Normal operation – Stage 6 When the dwell time of 20 minutes has expired, the B-T LED goes off. The icemaker goes through the normal start-up sequence when the bin level control signals the control board for ice. The WTR LED will remain on as long as the water sensor in the float reservoir senses water. RED WTR B-E B-T 2ND 60M 20M C POWER DR WHITE BLACK YELLOW WHITE 4 3 2 T.O.L. START RUN GEARMOTOR COMPRESSOR R POTENTIAL START RELAY RUN CAP. CAPACITOR START C S 2 1 5 T.O.L. L1 L2 COMP FAN DRV WATER SENSOR G GREEN/YELLOW GRN IN ELEC BOX BROWN BLUE WHITE WHITE BLACK BLACK ORANGE RED BLACK BLACK BLACK BLACK VIOLETVIOLETWHITEBLACKREDRED BLUE BLACK FAN M ORANGE BLACK L N HIGH PRESSURE SAFETY SWITCH COMPRESSOR SWITCH BIN T-STAT BIN SIGNAL SWITCH DISPENSER Diagnostic sequence – Stage 7 The 20 minute error LED (20M) is on, indicating that the control board has sensed an over-torque condition (above 2.5 AMPS on the gearmotor). The 20M LED remains on for 20 minutes after an over-torque condition has occurred. The icemaker remains off as long as the 20M LED is on. When the 20M LED goes off, the control board will try to go through a normal start-up sequence. The WTR LED remains on as long as the water sensor in the float reservoir senses water. RED WTR B-E B-T 2ND 60M 20M C POWER DR WHITE BLACK YELLOW WHITE 4 3 2 T.O.L. START RUN GEARMOTOR COMPRESSOR R POTENTIAL START RELAY RUN CAP. CAPACITOR START C S 2 1 5 T.O.L. L1 L2 COMP FAN DRV WATER SENSOR G GREEN/YELLOW GRN IN ELEC BOX BROWN BLUE WHITE WHITE BLACK BLACK ORANGE RED BLACK BLACK BLACK BLACK VIOLETVIOLETWHITEBLACKREDRED BLUE BLACK FAN M ORANGE BLACK L N HIGH PRESSURE SAFETY SWITCH COMPRESSOR SWITCH BIN T-STAT BIN SIGNAL SWITCH DISPENSER 25 Diagnostic sequence – Stage 8 If the restart is successful the 20M LED goes off, the 60 minute timer LED (60M) comes on. The 60M LED will remains on for 60 minutes from restart. A lighted 60M LED indicates the icemaker has experienced an over-torque condition. If the icemaker runs without problems for 60 minutes and no additional torque errors occur, the 60M LED goes off and the icemaker continues normal operation. RED WTR B-E B-T 2ND 60M 20M C POWER DR WHITE BLACK YELLOW WHITE 4 3 2 T.O.L. START RUN GEARMOTOR COMPRESSOR R POTENTIAL START RELAY RUN CAP. CAPACITOR START C S 2 1 5 T.O.L. L1 L2 COMP FAN DRV WATER SENSOR G GREEN/YELLOW GRN IN ELEC BOX BROWN BLUE WHITE WHITE BLACK BLACK ORANGE RED BLACK BLACK BLACK BLACK VIOLETVIOLETWHITEBLACKREDRED BLUE BLACK FAN M ORANGE BLACK L N HIGH PRESSURE SAFETY SWITCH COMPRESSOR SWITCH BIN T-STAT BIN SIGNAL SWITCH DISPENSER Diagnostic sequence – Stage 9 The...

Ce manuel est également adapté pour les modèles :
Autres appareils de cuisine - ER400A (1.97 mb)
Autres appareils de cuisine - ED400A/W (1.97 mb)
Autres appareils de cuisine - ET400A/W (1.97 mb)
Autres appareils de cuisine - MFE400A/W (1.97 mb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories