|
Facilité d'utilisation
READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. OBSERVE ALL GOVERNING CODES AND ORDINANCES. WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or death. Do not store or use gasoline or other flammable vapors and liquid in the vicinity of this or any other appliance. WHAT TO DO IF YOU SMELL GAS - Do not try to light any appliance. - Do not touch any electrical switch. - Do not use any phone in your building. - Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. - If you cannot reach your gas suppliers, call the fire department. Installation and service must be performed by a qualified installer, service agency or the gas supplier. Read this instruction booklet before installing and using the appliance. The manufacturer will not be responsible for any damage to property or to persons caused by incorrect installation or improper use of the appliance. The manufacturer reserves the right to make changes to its products when considered necessary and useful, without affecting the essential safety and operating characteristics. This appliance has been designed for non-professional, domestic use only. Cod. 310283 INDEX: Installation Instructions……………………………………..………………………..pag.2 Inserting the hotplate……………………………………………..…………………..pag.3 Requirements……………………………………..……………………………….…..pag.3 Attaching the hotplate……………………………………..………………………….pag.4 Gas connection……………………………………..…………………………………pag.4 Electrical connection……………………………………..……………………….…..pag.5 Wiring diagrams……………………………………..…………………………….…..pag.5 Room ventilation…………………………………….…………………………………pag.5 Location and venting…………………………………….…………………………….pag.5 Replacement of nozzles……………………………………..………………………..pag.5 Regulation of burners……………………………………………...………………….pag.6 Descriptions…………………………………………………………………………….pag.6 Service & maintenance instructions……………………………..…………………..pag.6 Greasing the valves……………………………………………..…………………….pag.7 User instructions……………………………………………..………………………..pag.7 Using burners……………………………………………………..……………………pag.7 Cleaning the appliance……………………………………………..…………………pag.8 Figures………………………………………………...…………..……………………pag.19 Installation instructions This appliance shall only be installed by an authorized person. This appliance shall be installed in accordance with the manufacturers installation instructions, IMPORTANT: this appliance must be installed in accordance with the norms in force of the country concerned. The installation of this appliance must conform to local codes and ordinances. In the absence of local codes, Installations must conforms to American National Standards, National Fuel Gas Code ANSI Z223.1 – latest edition** or B149.1. If local codes permit, a flexible metal appliance connection with the new AGA or CGA certified design, max. 5 feet (1,5 m) long, .” I.D. recommended for connecting this cooktop to the gas supply line. Do not bend or damage the flexible connector when moving the cooktop. The pressure regulator has .” female pipe thread. You will need to determine the fitting required, depending on the size of your gas supply line, the flexible metal connector and the shutoff valve. The appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70. The appliance and its individual shutoff valve must be disconnected from the gas supply piping system any pressure testing of that system at test pressure in excess of . psi (3,5 kPa). The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than . psi (3.5 kPa). For use with a pressure regulator. The regulator supplied must be used with this appliance. The gas appliance pressure regulator must be set for the gas with which the appliance is used. This appliance can be used with Natural Gas and LP Gas. It is shipped from the factory adjusted for use with Natural Gas: CONVERSION FIXED ORIFICES ARE LOCATEDIN THE LITERATURE PACK SUPPLIED WITH THE UNIT. Injectors kit for the change of type of gas are contained inside the package jointly with the hob installation kit and Instruction booklet. The maximum inlet gas supply pressure incoming to the gas appliance pressure regulator is 20’’ water column (5 kPa) . 2 The minimum gas supply pressure for checking the regulator setting shall be at least 1“ w.c. (249 Pa) above the inlet specified manifold pressure to the appliance (this operating pressure is 4” w.c. (1.00 kPa) for Natural Gas and 11” w.c. (2.75 kPa) for LP Gas). ATTENTION: A manual valve shall be installed in an accessible location in the gas line external to the appliance for the purpose of turning on or shutting off gas to the appliance WARNING: Do not use aerosol sprays in the vicinity of this appliance while it is in ...
Ce manuel est également adapté pour les modèles :Autres appareils de cuisine - B3Y0..U4X(2 OR 5)D (1.46 mb)