Fabricant : Connerton Co
Taille : 62.14 kb
Nom Fichier : e484e203-6314-4f19-8480-04ca87976170.pdf
|
Facilité d'utilisation
. . . CEG SERIES THERMOSTATIC GRIDDLES For Your Safety Warning! Do NOT store or use gasoline or Improper installation, adjustment, alteration, service or other flammable vapors and maintenance can cause property damage, injury or liquids in the vicinity of this, or death. Read the installation, operation and maintenance any other equipment. instructions thoroughly before installing or servicing this equipment. To Purchaser After installation of your griddle, immediately contact your local gas supplier to obtain information in the event the user of your equipment smells gas. This information must be posted in a prominent location. To User RETAIN THIS MANUAL FOR FUTURE USE Upon receipt of this griddle, inspect it thoroughly for any damage which may have occurred during shipment. If damage is observed, contact the delivery agency immediately. 1. Preparation For Installation: Safe and satisfactory operation of the griddle depends, to a great extent, upon it’s proper installation. It should be installed in accordance with the National Fuel Gas Code Z223.1, these instructions, and applicable State and Local Codes. Installation must be made by a licensed plumber. A gas pressure regulator is supplied with your griddle. The regulator must be installed before connecting griddle to gas supply line. Please note: air vent can plug with grease, thereby shutting gas supply off. Install regulator in a drip-free area. The griddle and it’s individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psig (3.45 kPa). The griddle must be isolated from the gas supply piping system by closing it’s individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig (3.45 kPa). 2. Clearances And Ventilation: This griddle is designed for installation in non-combustible locations only with 4” clearance from sides and 6” clearance from back. . . !". ###$ %&$. Keep equipment area free and clear from combustibles. The area in front of, and above the griddle must be clear to avoid obstruction of flow of combustion and ventilation air. Means must be provided for adequate air supply and adequate clearance for air openings into the combustion chamber. Adequate clearances must be provided in front and sides of the griddle for servicing and proper operation. It is important that the griddle be installed under an exhaust hood which is adequate to remove the products of combustion and cooking vapors. Sufficient make-up air must also be provided to the space where the griddle is located to replace that removed through the exhaust hood. 3. Gas Piping: Make sure the gas pressure regulator supplied with the griddle is installed correctly. Connect outlet side of regulator to griddle. The regulator is set at 4 inches w.c. on natural gas and 11 inches w.c. on propane gas. A 1/8” pressure tap is provided on the gas manifold at the front of the griddle for checking the gas pressure. Please note: air vent on regulator can plug with grease, thereby shutting gas supply off. Install regulator in drip-free area. Connect griddle to the gas supply line. Under no circumstances should the gas supply line be smaller than the inlet pipe on the griddle. A gas shutoff valve must be installed in the gas supply line upstream of the griddle for complete shutdown and service. Use pipe sealant on all pipe joints. Sealant must be resistant to the action of L.P. gasses. For proper performance, the griddle must be level. If legs are provided, adjust feet at bottom of legs to level griddle. If legs are not provided, seal the base of the griddle to the countertop with silicone. If the griddle is supplied with casters, the installation must be made with a connector that complies with the Standard for Connectors for Movable Gas Appliances ANSI Z21.69 , and a quick-disconnect device that complies with the Standard for Quick-Disconnect Devices for Use With Gas Fuel, ANSI Z21.41 . Adequate means must be provided to limit the movement of the griddle without depending on the connector and the quick-disconnect device or it’s associated piping to limit the griddle movement. Restraining device should be connected to legs or back of body. IMPORTANT: Check all gas connections for leaks, using a soap and water solution. DO NOT USE AN OPEN FLAME FOR CHECKING PURPOSES 4. Lighting And Relighting Of Griddle: A. Turn all pilot valves and thermostat knob(s) to “OFF”. Wait 5 minutes. B. Turn on pilot valves and light pilots. Adjust flame height to approximately 1/2”. C. Turn on thermostat knobs to operate your griddle. D. For complete shutdown, turn off all thermostat knobs, pilot valves, and the gas shutoff valve located upstream of the griddle. E. To relight, repeat above procedures. 5. Care And Maintenance: Contact factory, factory representative, or a local service company to perform maintenance and repairs. Ple...