Log:
Évaluations - , GPA: ( )

Instructions American Standard, Modèle 2742.328

Fabricant : American Standard
Taille : 154.59 kb
Nom Fichier : 0ec17050-30a3-44a3-abb6-f5053d389bc5.pdf

Langue d'enseignement: en

Le document est chargé, s'il vous plaît patienter
Le document est chargé, s'il vous plaît patienter

Facilité d'utilisation


2/08 AtotMiüM Shwda/rd Style That Works Better TOWN SQUARE® 6’ x 42" PREMIUM AIR BATH HIGH GLOSS 4"_ (102mm) C/L OF-DRAIN OUTLET 3/4' (19mm) 71-1/2" (1816mm) INTEGRAL FITTING DECK 2-1/4" X 14" (57 X 356mm) o ^ o 7-3/4” TYPICAL (197mm) FLOOR CUTOUT 9" X 19" o o (229 X 459mm) EDGE OF FLOOR CUTOUT T ^—AIR BLOWER OUTLINE OF SKID-RESISTANT SURFACE ^-20 AIR JETS OUTLINE OF CUTOUT 70" X 40-1/4" (1778 X 1022mm) PROVIDE ACCESS--TO BLOWER FOR SERVICE ON ALL INSTALLATIONS 2" (51mm) LEVELING STRINGER INTEGRAL FEET WITH ATTACHED BASEBOARD 1-1/2" N.P.T. THREADS 1-1/2" O.D.TAILPIECE' C/L OF OVERFLOW 22" (559mm) 3" (76mm) GENERAL SPECIFICATIONS FOR 2742 AIR MASSAGE SYSTEM INSTALLED SIZE -71-1/2 x 41-3/4 x 22 In. (1816 x 1060 x 559mm) WEIGHT_115 Lbs. (52 Kg.) WEIGHT w/WATER _ 690 Lbs. (313 Kg.) GAL. TO OVERFLOW _ 69 Gal. (261 L) BATHING WELL AT SUMP_41 x 21-1/2 In. (1041 x 546mm) BATHING WELL AT RIM _62 x 31-1/2 In. (1574 x 800mm) WATER DEPTH TO OVERFLOW _14-1/4 In. (362mm) FLOOR LOADING _33 Lbs./Sq.Ft. (163 Kgs./Sq.m) (PROJECTED AREA) PTS--27.8 CUBE (FT3)_55.7 ELECTRICAL SPECIFICATIONS BLOWER_1.0 HP, 10 AMPS ,120V. NOTES: BATH CAN BE INSTALLED EITHER ABOVE OR BELOW FLOOR LINE AS PIER, ISLAND OR PENINSULA TYPE INSTALLATION. SUMP OF BATH IS SUPPORTED BY INTEGRAL FEET. NO ADDITIONAL SUPPORT REQUIRED. ENCLOSING MATERIALS BY OTHERS. • IF INSTALLING A DECK-MOUNTED FITTING, BEFORE DRILLING ANY HOLES: CHECK FOR INTERFERENCE WITH CIRCULATING SYSTEM PIPING AND DRAIN OVERFLOW. MOUNTING HOLES DRILLED BY INSTALLER. ■ REFER TO INSTALLATION INSTRUCTIONS SUPPLIED WITH BATH FOR ADDITIONAL INFORMATION. FITTINGS NOT INCLUDED AND MUST BE ORDERED SEPARATELY. PROVIDE SUITABLE REINFORCEMENT FOR ALL SUPPORTS. IMPORTANT: Dimensions of fixtures are nominal and may vary within the range of tolerances established by ANSI Standard Z124.1 / CSA Certified. These measurements are subject to change or cancellation. No responsibility is assumed for use of superseded or voided leaflet. © 2008 AS America Inc. H24 Rev. 2/08...

Ce manuel est également adapté pour les modèles :
Autres accessoires pour la maison - 2742.328.K2 (154.59 kb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories