Log:
Évaluations - 4, GPA: 4.5 ( )

Instructions Hampton Direct, Modèle U32-NG2

Fabricant : Hampton Direct
Taille : 4.07 mb
Nom Fichier :
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


FPI offers an optional programmable thermostat but any 250750 millivolt rated non-anticipator type thermostat that is CSA, ULC or UL approved may be used. Thermostat Wire Table Recommended Maximum Lead Length (Two-Wire) When Using Wall Thermostat (CP-2 System) Wire Size Max. Length 14 GA. 50 Ft. 16 GA. 32 Ft. 18 GA. 20 Ft. 20 GA. 12 Ft. 22 GA. 9 Ft. CAUTION Do not connect the millivolt wall thermostat wires to the 120V wires. OPTIONAL REMOTE CONTROL Use the FPI Remote Control Kit approved for this unit. Use of other systems may void your warranty. The remote control kit comes with a hand held transmitter, a receiver and a wall mounting plate. 1) Choose a convenient location on the wall to install the receiver and the receptacle box (protection from extreme heat is very important). Run wires from the fireplace to that location. Use Thermostat Wire Table. 2) Connect the wires as per the wiring diagrams below. CAUTION Do not connect the millivolt remote control wires for to the 120V wires. 3) Install 3 AAA alkaline batteries in transmitter and 4 AA alkaline batteries in the receiver. Install the receiver and its cover in the wall. Switch the remote receiver to "remote" mode. The remote control is now ready for operation. FINAL CHECK Before leaving this unit with the customer, the installer must ensure that the appliance is firing correctly. This includes: 1) Clocking the appliance to ensure the correct firing rate (rate noted on label) at 15 minutes. 2) If required, adjusting the primary air to ensure that the flame does not carbon. First allow the unit to burn for 15 min. to stabilize. 3) Check for proper draft. CAUTION Any alteration to the product that causes sooting or carboning that results in damage to the exterior facia is not the responsibility of the manufacturer. U32-2 FPI Direct Vent Gas Insert INSTALLATION WIRING DIAGRAM This heater does not require a 120V A.C. supply for operation. In case of a power failure, the burner switch and the optional remote control/thermostat will continue to operate. However, a 120V A.C. power supply is needed for the fan/blower operation. CAUTION: Label all wires prior to disconnection when servicing con- trols. Wiring errors can cause im- proper and dangerous operation. Caution: Ensure that the wires do not touch any hot surfaces and are away from sharp edges. WARNING: Electrical Grounding Instructions This appliance is equipped with a three pronged (grounding) plug for your protection against shock hazard and should be plugged directly into a properly grounded three- prong receptacle. Do not cut or remove the grounding prong from this plug. U32-2 FPI Direct Vent Gas Insert OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS Before operating this appliance, proceed through the following check list. 1) Read and understand these Instructions before operating this appliance. 2) Check to see that all wiring is correct and enclosed to prevent possible shock. 3) Check to ensure there are no gas leaks. 4) Make sure the glass door is in place. Never operate the appliance with the door glass removed. 5) Verify that all venting and the cap is unobstructed. 6) Verify log placement. If the pilot cannot be seen when lighting the unit - the logs or the embers have been incorrectly positioned. 7) The unit should never be turned off and on again without a minimum of a 60 second wait. 8) When lighting the appliance, the inside of the glass may fog up. This will burn off after a few minutes of operation. DO NOT BURN THE APPLIANCE WITH THE GLASS ASSEMBLY REMOVED. LIGHTING PROCEDURE IMPORTANT: Gas cock knob cannot be turned from "PILOT" to "OFF" unless it is partially depressed. 1) Open the bottom louver assembly 2) If the control knob is in the "OFF" position proceed to Step 5. 3) Push in gas control knob slightly and turn clockwise to "OFF". Knob cannot be turned from "PILOT" to "OFF" unless knob is pushed in slightly. Do not force. 4) Wait five minutes to allow gas, that may have accumulated in the main burner compartment, to escape. If you do smell gas, follow the instructions on the front of this manual. If you don't smell gas continue on to the next step. 5) Turn the gas control counter clockwise to "PILOT". 6) Push in control knob all the way and hold in. Continually push and release the black button on spark igniter until pilot lights. Continue to hold the control knob in for approximately one minute, then release the gas control knob. The pilot flame should continue to burn. If the pilot does not remain lit, repeat operation allowing a longer period before releasing gas control knob. 7) Turn gas control knob counter clockwise to "ON". 8) Use the rocker switch to operate main burner. 9) Rotate the variable flame control to adjust the flame height higher or lower. 10) Close the bottom louver assembly. SHUTDOWN PROCEDURE 1) Use the rocker switch to turn off the main burner. 2) Open the bottom louver assembly. 3) Push in the gas control knob slightly and turn clockwise to "OFF". Do not fo...

Ce manuel est également adapté pour les modèles :
Autres accessoires pour la maison - U32-LP2 (4.07 mb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories