Log:
Évaluations - , GPA: ( )

Instructions Regency, Modèle I31-NG3

Fabricant : Regency
Taille : 3.07 mb
Nom Fichier :

Langue d'enseignement: en

Le document est chargé, s'il vous plaît patienter
Le document est chargé, s'il vous plaît patienter

Facilité d'utilisation


Grill Stop Bracket 2) Place top grill into brackets located inside top of firebox as shown. Bracket inside top of firebox. Bracket Top Grill 3) The bottom louver, shown in the diagram below, has 2 hinges that are attached to the lip on bottom of the unit. Secure using 2 screws per hinge. INSTALLATION BAROSSA CURVED FRONT INSTALLATION 1) Install bottom louver by matching the holes in louver bracket with holes 4) Fit plates on back of screen into brackets on top of firebox. Press in firebox frame and secure using 2 screws on each side. in to secure from top. 5) Secure bottom of screen using 1 screw on each side into the Brackets on firebox. Secure louver by using 2 screws. brackets fixed onto the firebox in step 3. 2) Pull down louver. 3) Fix brackets onto firebox, one on each side using 1 screw per side. Secure with screw. Secure bracket 6) Close louver. with screw. Regency I31-3 Gas Fireplace Inbuilt INSTALLATION OPTIONAL REMOTE CONTROL Use the Optional Remote Control Kit approved for this unit. Use of other systems may void your warranty. The remote control kit comes with a hand held transmitter, a receiver and a wall mounting plate. 1) Choose a convenient location on the wall to install the receiver and the receptacle box (protection from extreme heat is very important). Run wires from the fireplace to that location. Use Thermostat Wire Table. 2) Connect the two wires to the gas valve. 3) Install a 9V alkaline battery in both receiver and the transmitter. Install the receiver and cover in the wall. The remote control is now ready for operation. CAUTION Do not connect the millivolt remote control wires to the 240V wires. OPTIONAL WALL THERMOSTAT A wall thermostat may be installed if desired. Use chart below to determine thermostat wire length. Note: Preferable if the thermostat is installed on an interior wall. Use a CSA, UCL or UL approved millivolt thermostat, 250-750 millivolt rated. A non-anticipator type thermostat must be used. CAUTION Do not connect the millivolt wall thermostat wires to the 240 V wires. Thermostat Wire Table Recommended Maximum Lead Length (Two-Wire) When Using Wall Thermostat (CP-2 System) Wire Size Max. Length 14 GA. 15.24 m 16 GA. 9.75 m 18 GA. 6.10 m 20 GA. 3.66 m 22 GA. 2.71 m No electrical power supply is required for the gas control to operate. However, a 240V A.C. power supply is needed for the fan/blower operation. Caution: Ensure that the wires do not touch any hot surfaces and are away from sharp edges. WIRING WARNING: Electrical Grounding Instructions CAUTION: This appliance is equipped with a three pronged Label all wires prior to(grounding) plug for your protection against disconnection when shock hazard and should be plugged directly servicing controls. into a properly grounded three-prong recepta-Wiring errors can causecle. Do not cut or remove the grounding prong improper and dangerousfrom this plug. operation. Regency I31-3 Gas Fireplace Inbuilt OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS Before operating this appliance, proceed through the following check list. 1) Read and understand these Instructions before operating this appliance. 2) Check to see that all wiring is correct and enclosed to prevent possible shock. 3) Check to ensure there are no gas leaks. 4) Make sure the glass door is in place. Never operate the appliance with the door glass removed. 5) Verify that all flueing and the cap is unobstructed. 6) Verify log placement. If the pilot cannot be seen when lighting the unit - the logs or the embers have been incorrectly positioned. 7) The unit should never be turned off and on again without a minimum of a 60 second wait. 8) When lighting the appliance, the inside of the glass may fog up. This will burn off after a few minutes of operation. DO NOT BURN THE APPLIANCE WITH THE GLASS ASSEMBLY REMOVED. LIGHTING PROCEDURE IMPORTANT: Gas cock knob cannot be turned from "PILOT" to "OFF" unless it is partially depressed. 1) Open the bottom louvre assembly 2) If the control knob is in the "OFF" position proceed to Step 5. 3) Push in gas control knob slightly and turn clockwise to "OFF". Knob cannot be turned from "PILOT" to "OFF" unless knob is pushed in slightly. Do not force. 4) Wait five minutes to allow gas, that may have accumulated in the main burner compartment, to escape. If you do smell gas, follow the instructions on the front of this manual. If you don't smell gas continue on to the next step. 5) Turn the gas control counter clockwise to "PILOT". 6) Push in control knob all the way and hold in. Continually push and release the black button on spark igniter until pilot lights. Continue to hold the control knob in for approximately one minute, then release the gas control knob. The pilot flame should continue to burn. If the pilot does not remain lit, repeat operation allowing a longer period before releasing gas control knob. 7) Turn gas control knob counter clockwise to "ON". 8) Use the rocker switch to operate main burner. 9) Rotate the variable fla...

Ce manuel est également adapté pour les modèles :
Autres accessoires pour la maison - I31-LPG3 (3.07 mb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories