|
Facilité d'utilisation
None. system_ reboot Alarm Yellow “Switch sw1a was rezoned” This event reports changes in the zoning of a switch. enclosure Audit “Auditing a new switch called ras d2-swb1 (ip=xxx.0.0.41) 10002000007a609” oob Comm_ Established “Communication regained with sw1a (ip=xxx.20.67.213)” 82 Sun StorEdge 3900 and 6900 Series 2.0 Troubleshooting Guide • March 2003 Sun Proprietary/Confidential: Internal Use Only TABLE 7-2 Storage Automated Diagnostic Environment Event Grid for 2 GBit Switches (Continued) ComponentEventTypeSeverityActionDescriptionNote:Text withinquotation marks(“ “) is exactlyas it appears onthe Event Grid. ActionRequired oob Comm_ Lost Down Y “Lost communication with sw1a (ip=xxx.20.67.213)” Ethernet connectivity to the switch has been lost. 1. Check Ethernet connectivity to the switch. 2. Verify that the switch is booted correctly with no POST errors. 3. Verify that the switch Test Mode is set for normal operations. 4. Verify the TCP/IP settings on switch by way of Forced PROM Mode access. 5. Replace switch, if needed. switch2 test Diagnostic Test- Red Check Test Manager for failure details. enclosure Discovery “Discovered a new switch called ras d2-swb1 (ip=xxx.0.0.41) 10002000007a609” Discovery events occur the very first time the agent probes a storage device. It creates a detailed description of the device monitored and sends it using any active notifier such as the SunTM Remote Services (SRS) Net Connect service or email. enclosure Location Change “Location of switch rasd2swb0 (ip xxx.0.0.40) was changed” Chapter 7 Troubleshooting Switches 83 Sun Proprietary/Confidential: Internal Use Only TABLE 7-2 Storage Automated Diagnostic Environment Event Grid for 2 GBit Switches (Continued) ComponentEventTypeSeverityActionDescriptionNote:Text withinquotation marks(“ “) is exactlyas it appears onthe Event Grid. ActionRequired port State Change+ “port.1 in SWITCH diag185 (ip= xxx.20.67.185) is now Available (status-state changed from offline to online)” The port on the switch is now available. port State Change- Red Y A port on switch2 has logged out of the Fabric connection and has gone offline. 1. Verify cables, GBICs, and connections along the FC path. 2. Check the Storage Automated Diagnostic Environment SAN Topology GUI to identify failing segment of the data path. 3. Verify the correct FC switch configuration. enclosure Statistics “Statistics about switch d2-swb1 (ipxxx.0.0.41) 10002000007a609” 84 Sun StorEdge 3900 and 6900 Series 2.0 Troubleshooting Guide • March 2003 Sun Proprietary/Confidential: Internal Use Only setupswitchExit Values TABLE 0-1 lists the setupswitch exit values. The associated messages are logged in the /var/adm/log/SEcfglog file. TABLE 0-1 setupswitch Exit Values Severity Level Message Type Message Meaning 0 INFO All switch settings are properly set. The switch setting matches the default configuration. 1 ERROR Errors occurred while you tried to set the proper switch settings.The switch setting does not match the default configuration or any valid alternatives. 2 WARNING Errors occurred while you tried to set the proper switch settings. The ports did not self-configure properly. A cable connection might not be working properly. T ports self-configure (that is, the configuration tool cannot control the configuration) from F ports when they are cabled properly. Specifically, these are the ports on the back-end switches in Sun StorEdge 6900 series configurations only. The ports support the ISL connections. 3 WARNING The Flash code is different from the release level. The switch Flash code does not match the current release version. The Sun StorEdge network FC switch-8 and switch-16 switches periodically releases new versions of the switch Flash code and the new version will not match the default version. 4 WARNING The configuration is not set to the default, but the differences are likely supported alternatives. The default switch configurations were overridden with valid alternatives, which are also supported by the SUNWsecfg configuration tools. It should still be flagged as “not the default.” The exit value can imply any of the following alternatives (these messages are printed to the screen and to the Storage Automated Diagnostic Environment GUI): • Some ports have been set to SL, TL, or F mode, but should have been set using the setswitcht1 or setswitchf commands. View and verify this nonstandard configuration setup as required, using the showswitch command. Refer to the Sun StorEdge 3900 and 6900 Series Version 1.1 Reference and Service Guide for detailed configuration information. • The chassis ID on the switch is not set to the default value. This could be caused by unique ID settings or by conflicts in a SAN environment. • Ports are identified that are not in the default hard zone. This could be because the port is set to the same hard zone as the cascaded switch in a SAN environment or the user has run the modifyswitch(1M) command on a Sun StorEdge 3900 Series system Cha...
Ce manuel est également adapté pour les modèles :Autres accessoires pour la maison - 3900 (3.02 mb)