Log:
Évaluations - 7, GPA: 4 ( )

Instructions Jacuzzi, Modèle J-DREAM II

Fabricant : Jacuzzi
Taille : 1.08 mb
Nom Fichier : 51af827b-1670-47f4-93f1-3fd340772085.pdf
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


Route the water filter line and control cable to the equipment side wall. Control Cable Hot Water Supply (with braided metal sheathing) To Cascade Tee Steam Line (with black insulation cover) To Valve 1 To Valve 3 To Valve 6 To Valve 7 From Water Filters Cold Water Supply (with braided metal sheathing) To Manifold CD/Radio Speaker and Power Wires To Cascade Fitting To Jets To Steam Head 20 J-Dream II Owner's Manual Right Seat Wall (Equipment Wall) Connect the hoses routed from the back wall as below (grayed lines are pre-attached). Connect the controller line. The red and black leads in the CD/Radio wire bundle must be hooked up to the corresponding colored leads of the power supply. Connect the speaker leads. Connect the two SteamPro power cords after unraveling them. Adaptor Jack From Backwall From Backwall Power Cords from SteamPros From Bottom of Mixer on Backwall CD Power and Speaker Wires From Backwall (Diconnect This Hose When Accessing Equipment on This Seat Wall) Cascade Tee Red (+) lead Black (-) lead CD/Radio power supply Manifold From mixer Back of Right Seat Wall Steam Line from Backwall (with black insulation cover) 1367 Valve # A B B A Bonding Wire 5 4 2 From Control Panel To Tee on Cold Water Line 21 J-Dream II Owner's Manual Bonding (top left hand side of right hand equipment seat wall) Connect a #8 guage (10mm2) minimum solid copper bond wire to the house electrical pannel or an approved local ground. An approved ground may be an 8 foot long ground rod (3 meter long earth rod), a plate electrode or ther acceptable bond location. Check your local building code for requirements. (If necessary, remove one screw in the plastic cover plate on top of seat wall frame and swing plate out of the way for access.) POWER CORD JUNCTION BOX 22 J-Dream II Owner's Manual 1. Make sure electric power is OFF at main breaker. 2. Static test water supply hoses for leaks. 3. Plug power cord into GFCI protected wall outlet. 4. Move the assembled J-Dream II into final position. 5. Connect 2" shower drain (see page 9). 6. Adjust the levelling screws in the J-Dream II base feet and lock them in position. 7. Recheck fit of drain plumbing. 8. Secure J-Dream II in position using clamps provided as shown in Figure 1. 9. Connect showerhead hoses to wall outlets, snap drain cover into place. 10. Adjust the Optica mixer rotational limit stop. To adjust, consult the Optica instructions enclosed with this manual. Adjustable footFloor clamp Velcro® FIGURE 1 Secure J-Dream II in position on floor using clamps (provided) on two front feet. Lag bolt 23 24 Attach Front Panels to Unit Remove this screw before operation Ground Wire Speaker and power leads B Antenna Wire Rear view of CD/radio Screw (2) Tinnerman® Nuts (pre-installed) Front Panel B C D Front Panel D Velcro® Screw (2) L Important: Attach CD/Radio ground wire here Velcro® B A A C Frame Screw - to be removed to permit attachment of CD/Radio ground wire. Put ground wire terminal between lockwashers and retighten screw. Attach both left and right front panels with pre-installed Velcro®. On the left front panel, install 2 screws through the top of the panel. Connect the CD/radio ground wire, speaker/power connector and antenna wire before installing left front panel. Ground wire is bolted to the seat wall frame. J-Dream II Owner's Manual 25 Place cover on top of unit. Align notch in cover with the corresponding notch in the top metal frame. J-Dream II Owner's Manual Top Cover 26 Turn On Electric Power at Main Breaker Operate Unit and Check for Leaks Attach Bottom Front Panel to Unit Enclosure Base Frame Panel Velcro® Velcro® Removable Face Panels Use finishing strip material (not provided) to cover gap between J-Dream II and finshed wall. Do not attach finishing strips to face panels. Screws Bottom Face Panel fastened with Velcro® Take the bottom panel at an angle and insert under the bottom of the enclosure frame. Rotate backwards till it is up against the brackets with the pre-installed Velcro®. J-Dream II Owner's Manual Part II: Operating Instructions CONTROL PANEL System control is provided by the electronic display located inside the shower cabin (see Figure 1) The display is used to start up the five functions of the unit: the shower, the cascade waterfall, the hydromassage (all jets), hydromassage (pulsed jets), and the steam bath. The display is composed of clear symbols to identify the five functions. STEAM JETS PULSED JETS START BUTTON START BUTTON START BUTTON OFF BUTTON CASCADE START BUTTON HAND HELD SHOWER START BUTTON OFF WHIRLPOOL BATH R FIGURE 1. CONTROL PANEL AND DISPLAY Starting Any Function The mixer control valve must be ON for the functions of the control panel to be operational except for the steam function . After the mixer valve has been set and is ON, press any button to start that function. The steam function can be ON with any other function. Other functions can only be ON one at a time. Pressing the OFF button turns all functions OFF. Mixer Con...


Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories