Log:
Évaluations - 3, GPA: 3.7 ( )

Instructions AMX, Modèle Dimmer Enclosures w/Breakers RDA-ENC6B

Fabricant : AMX
Taille : 200.7 kb
Nom Fichier : 44e7830e-ddd4-4520-887f-5f213969e0b5.pdf
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


These enclosures contain circuit breakers. TOP VIEW 0.75" (19.05 mm) 6.0" (152.4 mm) SIDE VIEW 24.0" (610 mm) 24.0" (610 mm) These enclosures are CE, UL, and C-UL approved. They include circuit breakers and terminals for multi-phase wiring. They also provide 18 knockouts for 1/2", 3/4", and 1" conduits. RDA-ENC6B Configurations: - ENC6B/120 20 A Breakers - ENC6B/240 10 A Breakers RDA-ENC12B Configurations: - ENC12B/120 20 A Breakers - ENC12B/240 10 A Breakers RDK Configurations: - RDK-ENC6B with 1 RDC-PDC - RDK-ENC12B/240 2 RDC-PDC Sample RDK-ENC12B kit shown with 2 RDC-PDC 18.0" (457.2 mm) I ''UHU' MHIIÜ! Ulf Top, side, and bottom views are the same for both enclosures. Note: LINE INPUTS: 120 A MAX PER TERMINAL Use 75° C copper conductors only. ! terminals to 44 in-lbs. ^Torque t Til BOTTOM VIEW FIG. 1 Top, front, bottom, and side views of the RDA-ENC6B and RDA-ENC12B enclosures Installation Instructions: For indoor use only. Mount on vertical surface only. Maintain 12" (304.88 mm) minimum clearance above and below the enclosure. Route class 1 conductors through upper conduit knockouts. Route class 2 conductors through lower conduit knockouts. Use 75°C (167°F) copper conductors only. Install filler plate #28-10500 (RDA-EFP) in all unused openings. Install only UL approved modules (see the UL Number Cross Reference to AMX Lighting ID table on page 2). Enclosure Weights: • RDA-ENC6B: 16.5 lbs. (7.48 kg) • RDA-ENC12B: 17.5 lbs. (7.94 kg) Dimensions between center lines (from FIG. 2): RDA-ENC6B: • A to B = 16.0" (406.4 mm) • B to C = 22.88" (581.2 mm) RDA-ENC12B: • A to B = 16.0" (406.4 mm) • B to C = 22.88" (581.2 mm) Radia enclosures must be mounted on a vertical surface with a minimum of 12" (304.8 mm) clearance above and below the enclosure. Configuration for right and left mounting brackets for all Radia enclosures. à .A to B Top slot Maximum mounting screw size: #12 Bottom slot B to C _ jTlL I FIG. 2 Bracket configuration Specifications Maximum input wire #1/0 AWG (50mm2) Maximum line input is 120 A (per terminal) Torque input wire to 44 in-lbs. (5.0 N/m) Wire stripping length: 0.67 inches (17 mm) Input 1 feeds channels 1, 4, 7, and 10 Input 2a feeds channels 5 and 11 Input 2b feeds channels 2 and 8 Input 3 feeds channels 3, 6, 9, and 12 Breakers are UL 489 listed 10,000 AIC, 100% Switching Duty, Hydraulic-Magnetic The following section cross references the UL ID module numbers and AMX Lighting module IDs. The modules identified are the only ones that can be used in the RDA-ENC6B and RDA-ENC12B enclosures. UL Number Cross Reference to AMX Lighting ID UL ID AMX ID UL ID AMX ID UL ID AMX ID 28-10100 RDC-DC/120 28-10200 RDM-INC 28-10300 RDM-MR60 28-10110 RDC-DC/240 28-10210 RDM-2INC 28-10310 RDM-MDM 28-10120 RDC-DC/277 28-10220 RDM-INC50 28-10340 RDA-CHK 28-10130 RDC-PDC/120 28-10230 RDM-ZC, RDM-2ZC 28-10350 RDM-FDB RDM-2FDB RDM-3FDB RDM-HFDB 28-10133 RDC-PDC/240 28-10240 RDM...

Ce manuel est également adapté pour les modèles :
Autres accessoires pour la maison - Dimmer Enclosures w/Breakers RDA-ENC12B (200.7 kb)
Autres accessoires pour la maison - ENC12B (200.7 kb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories