Instructions Majestic Appliances, Modèle LDVR1

Fabricant : Majestic Appliances
Taille : 4.39 mb
Nom Fichier : 52ea7802-2427-ad64-f914-e89fbf268718.pdf
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


This appliance may be fitted with a Synetek ignition EB1 JUNCTION BOX 11/18/97 module. Installation of the remote on/off starter switch or wall thermostat on electronic ignition units. 1. Thread the wiring through the holes on the side panels of the appliance. Take care not to cut the wire or insulation on metal edges. Route the wire to a conveniently located receptacle box. 2. Attach the wire to the ON/OFF switch and install the switch into the receptacle box. 3. Connect the white wire from the wall switch or wall thermostat to the white wire terminal from the electronic module. Connect the black wire from the wall switch or the red wire from the wall thermostat, to the red wire terminal from the electronic module. LDVR Series Direct Vent Gas Fireplace POWER CORD CIRCUIT BOARD ON/OFF SWITCH OR WALL THERMOSTAT VALVE RED WHITE BLUE YELLOW PURPLE BLACK WHITE GREEN PILOT SENSING PILOT IGNITER ORANGE L1 L2 M O P O CLEAR FP1571 Fig. 9 SIT822 Valve with Synetek electronic control wiring diagram. General Venting Your fireplace is approved to be vented either through There must not be any obstruction such as bushes, FP1571 the side wall, or vertically through the roof. garden sheds, fences, decks or utility buildings within SIT822 24” (610mm) from the front of the termination hood. • Only CFM Corporation venting components specifi- Synetek wiring cally approved and labelled for this fireplace may be 4/05 used. • Vent terminations shall not be recessed into a wall or siding. • Horizontal venting which incorporates the twist lock pipe must be installed on a level plane without an inclining or declining slope. • Horizontal venting which incorporates the use of flex venting shall have an inclining slope from the unit of 1” (25 mm) per 24” (610 mm). Do not locate termination hood where excessive snow or ice build up may occur. Be sure to check vent termination area after snow falls, and clear to prevent accidental blockage of venting system. When using snow blowers, make sure snow is not directed towards vent termination area. Location of Vent Termination It is imperative the vent termination be located observing the minimum clearances as shown on the next page. *Check with local codes or in absence of same with CSAB149.1 Installation Codes (1991) for Canada or follow the current National Fuel Gas Code, ANSI Z223.1/ NFPA 54 for installations in the USA. 10 10007317 LDVR Series Direct Vent Gas Fireplace General Venting Information - Termination Location V V V V V V V X X X D E B B B C B M B A J K F L VENT TERMINATION AIR SUPPLY INLET AREA WHERE TERMINAL IS NOT PERMITTED H I ......... ........... Operable Operable Fixed Closed V B INSIDE CORNER DETAIL V A G N N CFM145a Canadian Installations1 US Installations2 A = Clearance above grade, veranda, porch, deck, or balcony 12” (30cm) 12” (30cm) B = Clearance to window or door that may be opened 6” (15cm) for appliances < 10,000Btuh (3kW), 12” (30cm) for appliances > 10,000 Btuh (3kW) and < 100,000 Btuh (30kW), 36” (91cm) for appliances > 100,000 Btuh (30kW) 6” (15cm) for appliances < 10,000 Btuh (3kW), 9” (23cm) for appliances > 10,000 Btuh (3kW) and < 50,000 Btuh (15kW), 12” (30cm) for appliances > 50,000 Btuh (15kW) C = Clearance to permanently closed window 12” (305mm) recommended to prevent window condensation 12” (305mm) recommended to prevent window condensation D = Vertical clearance to ventilated soffit located above the terminal within a horizontal distance of 2’ (610mm) from the center line of the terminal 18” (458mm) 18” (458mm) E = Clearance to unventilated soffit 12” (305mm) 12” (305mm) F = Clearance to outside corner see next page see next page G = Clearance to inside corner (see next page) see next page see next page H = Clearance to each inside of center line extended above meter/regulator assembly 3’ (91cm) within a height of 15’ (5m) above the meter/regulator assembly 3’ (91cm) within a height of 15’ (5m) above the meter/regulator assy I = Clearance to service regulator vent outlet 3’ (91cm) 3’ (91cm) J = Clearance to nonmechanical air supply inlet to building or the combustion air inlet to any other appliances 6” (15cm) for appliances < 10,000 Btuh (3kW), 12” (30cm) for appliances > 10,000 Btuh (3kW) and < 100,000 Btuh (30kW), 36” (91cm) for appliances > 100,000 Btuh (30kW) 6” (15cm) for appliances < 10,000 Btuh (3kW), 9” (23cm) for appliances > 10,000 Btuh (3kW) and < 50,000 Btuh (15kW), 12” (30cm) for appliances > 50,000 Btuh (15kW) K = Clearance to a mechanical air supply inlet 6’ (1.83m) 3’ (91cm) above if within 10 feet (3m) horizontally L = Clearance above paved sidewalk or paved driveway located on public property 7’ (2.13m)† 7’ (2.13m)† M = Clearance under veranda, porch, deck or balcony 12” (30cm)‡ 12” (30cm)‡ N = Clearance above a roof shall extend a minimum of 24” (610mm) above the highest point when it passes through the roof surface, and any other obstruction within a horizontal distance of 18” (450mm). 1 In accordance with the current CSA-B149...


Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories