Log:
Évaluations - , GPA: ( )

Instructions Image, Modèle IMSB73920

Fabricant : Image
Taille : 507.07 kb
Nom Fichier : 833c9244-17cc-4f7d-b949-644602ba3f31.pdf

Langue d'enseignement: en

Le document est chargé, s'il vous plaît patienter
Le document est chargé, s'il vous plaît patienter

Facilité d'utilisation


Label the breaker in such a way that the breaker will not be turned on accidentally. 10. Re-attach the access panel and the spa cover. REPLACING THE LIGHT BULB If the underwater light burns out, you will need to remove the access panel to replace it (see ATTACHING AND REMOVING THE ACCESS PANEL on page 14). Make sure the spa power is turned off. Next, locate the light housing. Turn the light housing counterclockwise and remove it from the spa shell. Light Housing Light Housing Light Bulb To replace the light bulb, pull the old light bulb out of the housing and insert a new light bulb. Re-attach the light housing to the spa shell. Re-attach the access panel to the spa. 15 Troubleshooting Most problems can be solved by following the simple steps below. Find the symptom that applies, and follow the steps listed. If further assistance is needed, call our Customer Service Department toll-free at 1-877-897-7493, Monday through Friday, 8 a.m. until 5 p.m. Central Time. 1. SYMPTOM: THE SPA WILL NOT OPERATE 6. SYMPTOM: THE WATER DOES NOT HEAT a. Check to see if the GFCI breaker is tripped or a. Make sure that the hydrotherapy spa is fully was not turned on. Reset the GFCI breaker. covered with the spa cover. The spa cover must be tight for the water to heat. Set the 2. SYMPTOM: THE CIRCUIT BREAKER OR THE air control to low. The water will heat at a rate GFCI TRIPS WHILE THE SPA IS OPERATING of 6°F per hour. If you are using the spa indoors and the room temperature is main- a. Reset the circuit breaker or the GFCI. If the cir- tained at 70°F, it will take approximately 6 to 8 cuit breaker or the GFCI trips again, contact a hours for the water to reach the set temperature. qualified electrician for service. b. If you are using the hydrotherapy spa outdoors, 3. SYMPTOM: THE PUMP HUMS it may take longer for the water to heat. See the chart below for the approximate heating a. The filter may be dirty or damaged. Remove time. the filter from the filter housing and clean or replace the filter (see page 13). Air Temperature Heating Time 70°F + 6 to 8 hours b. The pump may have a foreign object stuck in 50°F to 70°F 9 to 11 hours the impeller. Contact our customer service 30°F to 50°F 12 to 14 hours department. If the water still has not heated after four days, c. The pump may have a loose wire connection. contact our customer service department. Contact our customer service department. 7. SYMPTOM: THE WATER IS NOT BEING 4. SYMPTOM: THE PUMP HUMS, BUT DOES NOT CLEANED BY THE FILTER ROTATE a. Check to see if the filter are in place. Clean the a. The pump may be jammed. Contact our cus- filter if they are dirty. tomer service department. If your spa is no longer under warranty, contact a local spa and b. Check the chemical balance of the water. If the pool service provider. pH is incorrect, the sanitizing agents will not function properly. See the section on maintain 5. SYMPTOM: THE PUMP IS NOISY WHILE ing the proper pH balance on page 14. OPERATING 8. SYMPTOM: THE WATER PULSATES OR a. There may be debris in the pump. Contact our THERE IS MINIMUM WATER FLOW customer service department. a. This usually occurs only when the water level is b. The pump may have a bad bearing. Contact low. Add water until it is 2 to 4” above the skim- our customer service department. mer basket. b. The Filter Covers may not be tight. Make sure the Filter Covers are tight. 16 9. SYMPTOM: THE WATER LEVEL DROPS a. A clamp or seal inside the pump compartment may be loose. Check inside the pump compartment for excess water and watch the pump unit while it is operating to see if water drips from any of the plumbing. If you can identify the location of the leak inside the spa jet unit, tighten the clamp or replace the damaged seal. b. Some water loss due to evaporation is normal. If rapid water loss occurs, or if you notice wetness on the floor around the hydrotherapy spa, the spa shell may have a leak. Contact your local pool and spa service provider for repairs. 10. SYMPTOM: THE SPA JET UNIT CONTINUES TO RUN AFTER IT HAS BEEN SHUT OFF a. To turn the main jets off, press pump button 1 once or twice. Note: If the actual spa water temperature is below the set temperature, or if the spa is running a filter cycle, the heater pump/motor will not shut off. 17 Part List—Model No. IMSB73920/IMSG73920 R0602A Key No. Qty. Description 1 1 Thermometer Fitting 2 1 3-wire Power Cord 3 1 Filter Cover 4 8 Rubber Washer 1 Filter 6 2 Rubber Isolator 7 1 Blue Light Cover 8 1 Red Light Cover 9 4 #10 x 1 1/2” Sheet Metal Screw 1 2-speed Pump* 11 1 Spa Cover 12 9 Dual Rotary Jet Face 13 4 Jet Pump/Motor O-ring 14 1 Heater/Electronics Package* 3 Medium Jet Housing 16 1 Cartridge Plug 17 4 Suction Cover Assembly 18 4 Air Control Knob 19 1 1-speed Pump* 2 4-wire Power Cord 21 1 Diverter 22 1 Basket 23 8 1/4” Lock Washer 24 1 Filter Housing Door 1 Access Panel 26 4 Buckle 27 8 #4 x 3/4” Screw 28 8 1/4” x 1 1/2” Screw 29 1 Console With Overlay 1 Whirlpool Jet 31 8 1/4” Washer 32 1 ...

Ce manuel est également adapté pour les modèles :
Autres accessoires pour la maison - IMSG73920 (507.07 kb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories