|
Facilité d'utilisation
Place rubber washer (M) on shoulder bolt. Secure to bracket with lock washer (G) and hex nut (N). 7 I FIGURE 9 ENGAGEMINT HANDLE. PLUNGER ^ ON PUMP 5. 6. Place the engagement handle in reverse position, locked in the notch in the slotted bracket. See figure 10. Adjust the engagement rod by tightening the hex nut on the end of the rod until the plunger on tht pump is pushed all the way in when the engagement handle is locked in the reverse position. Insert a screwdriver into the slot in the plunger to keep the rod from turning as the hex nut is tightened. See figure 10. FIGURE 10 OPERATION BEFORE STARTING 1. Fill reservoir tank on log splitter with approx-mately 2-1/2 to 3 gallons of Dexron II automatic transmission fluid as follows. Check oil level befc re each use. A. Place log splitter in the operating position w th the beam level, using the stand provided. B. Remove the oil check plug.from the back of the log splitter. See figure 11. If oil starts to come out of the hole, oil level is correct. T it does not, remove the cap from the breatier tube and add oil until oil starts out of the check hole. C. Replace oil check plug. Replace cap on the breather tube. FUNNEL FIGURE 11 8 NOTE DO NOT operate log splitter without “""v proper amount of oil in reservoir tank (beam). 2. Fill sump with oil as instructed in the separate engine manual packed with your unit. 3. Fill fuel tank, using clean, fresh, regular grade automotive gasoline. Fill tank completely. NOTE Refer to engine manual packed with log splitter for complete instructions for the care and maintenance of engine. READ DIRECTIONS CAREFULLY. TO START ENGINE 1. Place throttle control lever in FAST or CHOKE position. See figure 12. 2. Place choke control in CHOKE position (if unit is so equipped). NOTE A warm engine may not require choking. FIGURE 12A - 5 H.P. Tecumseh engine shown CHOKE LEVER 3. Grasp starter handle, place one foot on wheel and pull starter handle with a quick, full arm stroke. Return rope slowly to the engine. 4. After engine starts, move choke control gradually to OFF position (if unit is so equipped). Move throttle control to desired engine speed. TO STOP ENGINE 1. Move throttle control lever to STOP position. 2. Disconnect spark plug wire from spark plug to prevent accidental starting while equipment is unattended. USING YOUR LOG SPLITTER A« WARNING J This unit should not be towed on any street, highway or public road. Any licensing needed to comply with the existing federal, local or state vehicle requirements is the sole responsibility of the purchaser. Make certain the stand is folded up against the beam when transporting. Your log splitter is designed for safe, efficient operation. BE CAREFUL TO KEEP HANDS AND FEET AWAY FROM MOVING PARTS. Engagement handle has three positions: (See figure 13) Forward - ram moves toward wedge. Neutral - ram stops in place. Reverse - ram returns. ENGAGEMENT HANDLE IN NEUTRAL POSITION. ENGAGEMENT HANDLE HELD IN FORWARD POSITION. ENGAGEMENT HANDLE LOCKED IN REVERSE POSITION. FIGURE 13 FIGURE 12B-8 H.P. Briggs and Stratton engine shown Maximum length that can be split is 26". 9 I TO OPERATE LOG SPLITTER: 1. Set throttle at maximum speed. 2. Place log on beam and hold in place with right hand. See figure 14. 3. Slowly move engagement handle forward until ram rests against log. Release engagement h. indie (Neutral). 4. Remove your hand from the log and step b< hind the ram. See figure 15. 5. Move engagement handle forward until log is split. 6. Move the engagement handle to the rear to ruturn ram. FIGURE 15 The ram should take approximately 12 seconds to make a complete cycle. This speed may var\ depending on throttle setting and temperature of oi . NOTE If you lock the engagement handle in the reverse slot, the ram will return until it hits the engagement bracket, which will throw the engagement handle into neutral automatically. Ac WA*RN*NG*( Never attempt to cut a log in half with the log splitter. See figure 16. Never stand next to the ram when operating. Always stand behind the ram. See figure 17. FIGURE 16 FIGURE 17 MAINTENANCE AJ* war*ningTî Always stop engine and disconnect spark plug wire before performing any maintenance or adjustments. ENGINE OIL Change oil first two (2) hours of operation. Check oil level every five (5) operating hours or each tirr«5-equipment is used. Change oil every twenty-five (25) operating hours or sooner if equipment is operated in extremely dusty or dirty conditions. Refer to engine manual for quantity and type of oil. 10 LOG SPLITTER RESERVOIR OIL Check oil in log splitter reservoir before every use. Refer to "Before Starting" under OPERATION section. hange the oil in the reservoir every 100 hours of operation. Remove the six hex bolts, lock washers and hex nuts which hold the end plate to the beam. Remove the plate and drain the oil. Be prepared to catch oil in a suitable container. ■...
Ce manuel est également adapté pour les modèles :Autres outils - 245-642-000 (1.76 mb)
Autres outils - 24642S (1.76 mb)