Log:
Évaluations - 3, GPA: 4.3 ( )

Instructions Design Dynamics, Modèle HCA-24-RFP

Fabricant : Design Dynamics
Taille : 2.13 mb
Nom Fichier :
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


1. Remove log set assembly from carton. 2. Remove all protective packaging applied to log set for shipment. 3. Check all items for any shipping damage. If damaged, promptly inform dealer where you bought appliance. GENERAL INFORMATION These vented decorative gas log sets incorporate uni-body constructed ceramic fiber logs and ember bed burner which glow realistically when the appliance is in operation. These units are remote controlled-decorative rated and are equipped with millivolt gas valves. The remote control allows for flame height adjustment, timer and on/off control. A spark ignition system (piezo) allows the gas pilot to be lit without the use of matches or batteries and permits operation of the heater during a power outage. These log sets come with a Floor Media Kit included. This kit is used to blend the floor and the log set together for a more natural look. INSTALLATION WARNING: A qualified ser- vice person must install heater. Follow all local codes. WARNING: Before installing in a solid fuel burning fireplace, the chimney flue and firebox must be cleaned of soot, creo- sote, ashes and loose paint by a qualified chimney cleaner. Creo- sote will ignite if highly heated.A dirtychimneyfluemaycreateand distribute soot within the house. Inspectchimneyfluefordamage. If damaged, repair flue damper before operating appliance. CAUTION:Thisheatercreates warmaircurrents.Thesecurrents move heat to wall surfaces next to heater. Installing heater next to vinyl or cloth wall coverings or operatingheaterwhereimpurities (such as, but not limited to, to- bacco smoke, aromatic candles, cleaning fluids, oil or kerosene lamps, etc.) in the air exist, may discolor walls or cause odors. WARNING: Special care is required if you are installing the unit into a sunken fireplace. You must raise the fireplace floor to allow access to gas log controls. This will insure adequate air flow and guard against sooting. Raise the fireplace floor using noncombustible material. CHECK GAS TYPE Use the correct gas type (natural or propane/LP) for your unit. If your gas supply is not correct, do not instal in fireplace. Call dealer where you bought the appliance for proper type of appliance. WARNING: This appliance is equipped for (natural or pro- pane/LP) gas. Field conversion is not permitted. FLUE OPENING SPECIFICATIONS Note: This vented appliance must be installed only in a solid-fuel burning fireplace with a working flue and constructed of noncombustible material. The fireplace chimney must have a permanent vent opening to outside of not less than 29 square inches or as determined from manufacturer's installation instructions. LOG SIZING REQUIREMENTS LOG SIZE MINIMUM FIREBOX SIZE HEIGHT DEPTH FRONT WIDTH REAR WIDTH 18" 24" 14" 18" 16" 18" 30" 34" 20" 24" 115481-01B INSTALLATION Continued VENTING SPECIFICATIONS FOR INSTALLATION The fireplace chimney flue and vent must be drafting properly. To check the vent for proper drafting: Light a tightly rolled newspaper on one end and place it at the inside front edge of the fireplace. Observe the smoke and be sure the vent is properly drawing it up the chimney. If the smoke spills o...

Ce manuel est également adapté pour les modèles :
Autres outils - HCA-18-RFN (2.13 mb)
Autres outils - HCA-18-RFP (2.13 mb)
Autres outils - HCA-24-RFN (2.13 mb)
Autres outils - HCM-18-RFN (2.13 mb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories