Instructions Honeywell, Modèle CTS-20

Fabricant : Honeywell
Taille : 362.46 kb
Nom Fichier :

Langue d'enseignement: en

Le document est chargé, s'il vous plaît patienter
Le document est chargé, s'il vous plaît patienter

Facilité d'utilisation


The recommended torque to be used on the terminal block connections is 5.93 in-lbs (0.67 Nm). The 62-0245—01 2 SOLID CORE AND SPLIT CORE 4-20 MA OUTPUT CURRENT SENSORS SOLID CORE AND SPLIT CORE 4-20 MA OUTPUT CURRENT SENSORS BUILDING AUTOMATION SYSTEM COMMON + 4-20 MA SIGNAL INPUT GND (SHIELD) + – +12-30 VDC DC POWER SUPPLY + – M23934 Fig. 6. Wiring example OPERATING SPECIFICATIONS Max Sensing Current Voltage: 600 Vac Table 1. Specifications by Product Number Product Number Core Type Output Range Jumpera Max. Current Continuous Max. Current for 6 secs. CTS-20-005-AVG-001 Solid 4-20 mA Average 0-5 Amps Fixed None 100 Amps 125 Amps CTS-20-050-AVG-001 Solid 4-20 mA Average 0-10 Amps 0-20 Amps 0-50 Amps Low Middle High 100 Amps 150 Amps 200 Amps 125 Amps 225 Amps 300 Amps CTS-20-250-AVG-001 Solid 4-20 mA Average 0-100 Amps 0-200 Amps 0-250 Amps Low Middle High 200 Amps 360 Amps 400 Amps 250 Amps 450 Amps 500 Amps CTS-20-005-VFD-001b Solid 4-20 mA True RMS 0-5 Amps Fixed None 60 Amps 100 Amps CTS-20-050-VFD-001b Solid 4-20 mA True RMS 0-10 Amps 0-20 Amps 0-50 Amps Low Middle High 60 Amps 100 Amps 160 Amps 80 Amps 200 Amps 300 Amps CTS-20-250-VFD-001b Solid 4-20 mA True RMS 0-100 Amps 0-200 Amps 0-250 Amps Low Middle High 160 Amps 320 Amps 400 Amps 200 Amps 400 Amps 500 Amps CTP-20-005-AVG-001 Split 4-20 mA Average 0-5 Amps Fixed None 100 Amps 125 Amps CTP-20-050-AVG-001 Split 4-20 mA Average 0-10 Amps 0-20 Amps 0-50 Amps Low Middle High 100 Amps 150 Amps 200 Amps 125 Amps 225 Amps 300 Amps CTP-20-200-AVG-001 Split 4-20 mA Average 0-100 Amps 0-150 Amps 0-200 Amps Low Middle High 135 Amps 180 Amps 250 Amps 200 Amps 300 Amps 400 Amps CTP-20-005-VFD-001b Split 4-20 mA True RMS 0-5 Amps Fixed None 60 Amps 100 Amps CTP-20-050-VFD-001b Split 4-20 mA True RMS 0-10 Amps 0-20 Amps 0-50 Amps Low Middle High 60 Amps 100 Amps 160 Amps 80 Amps 200 Amps 300 Amps CTP-20-200-VFD-001b Split 4-20 mA True RMS 0-100 Amps 0-150 Amps 0-200 Amps Low Middle High 135 Amps 180 Amps 250 Amps 200 Amps 300 Amps 400 Amps a All current sensors are shipped from the factory with the jumper set in the high range. b All VFD models have True RMS outputs and should be used with Variable Frequency Drives. Not CE compliant at this time. 3 62-0245—01 SOLID CORE AND SPLIT CORE 4-20 MA OUTPUT CURRENT SENSORS SOLID CORE AND SPLIT CORE 4-20 MA OUTPUT CURRENT SENSORS Problem Solution No reading • Confirm that you have +12 to 30 Vdc in series with the current sensor output terminals and the analog input of the control panel. • Check the polarity of the circuit. • Verify that the terminals are screwed down, wires are firmly in place. • Disconnect the input to the control panel and then insert a current meter (mA range) in series with the current sensor output to verify that the circuit is working properly. Erratic readings • Verify that the wires are terminated properly. • Check that the +12 to 30 Vdc input is clean. In areas of high RF interference, shielded cable may be necessary to stabilize signal. Inaccurate readings • If you suspect that the current sensor is not reading within the accuracy specifications, please contact the factory for assistance. CURRENT CONVERSION FORMULA To convert the current sensor output signal to a current reading. Current reading = mA output/20 mA x Amp Span. For example: For a reading of 4 mA with a 0-250 Amp span: Current reading = (4 mA/20 mA) x 250 A = 0 Amp. (0/16) X 250 = 0 NOTE: 4mA = 0 Amps 20 mA = 250 Amps Automation and Control Solutions Honeywell International Inc. Honeywell Limited-Honeywell Limitee 1985 Douglas Drive North 35 Dynamic Drive Golden Valley, MN 55422 Toronto, Ontario M1V 4Z9 customer.honeywell.com ® U.S. Registered Trademark © 2007 Honeywell International Inc. 62-0245—01 C.H. Rev. 06-07 ...

Ce manuel est également adapté pour les modèles :
Autres outils - CTP-20 (362.46 kb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories