circuitry. Disconnect power supply before installation. RESISTANCE (OHMS) Location Locate the remote sensor about 5 ft (1.5m) above the floor on an inside wall where it will be affected by freely circulating air at average room temperatures. Mounting 1. Loosen the cover locking screw with the Allen wrench provided and remove the device cover. 2. Run wire to the selected location. 3. Thread wire through the semicircular hole in the 2000 1800 1600 1400 1420 OHMS AT 75 F (24 C) 1200 1000 F 10 20 30 40 5060 70 80 90100 device. -10 0 10 20 30 40 TEMPERATURE (DEGREES) M4034 4. Make connections to the T7047 (see the Wiring section). 5. Select the proper screws for the application. Four Fig. 4. T7047C1025 Remote Sensor resistance mounting screws are provided: change with change in temperature. a. Two self-tapping type for wall mounting. b. Two for outlet box mounting. 6. If air drafts occur through the wall opening, eliminate with suitable material. 7. Fasten the T7047 on the wall or outlet box with screws through the mounting holes in the device. (See Fig. 2.) 8. Replace the cover and tighten the cover locking screw. THERMOSTAT MOUNTING TAB SLOT (2) WIRING TERMINALS MOUNTING TAB (2 INSIDE COVER) COVER MOUNTING SCREW (2) COVER LOCKING SCREW OUTLET BOX M20072 120K 100K 80K 60K 40K 20KRESISTANCE (OHMS) F 22,800 OHMS AT 77 F (25 C) 20 40 60 80 100 120 140 160 180 200 220 C -7 0 10 20 30 40 50 60708090100 TEMPERATURE (DEGREES) M3398 Fig. 5. T7047C1082 Remote Sensor resistance change with change in temperature. Fig. 2. Mounting the T7047. 3 62-0179 T7047C,G,H REMOTE SPACE SENSORS RESISTANCE (OHMS) 1000 900 800 700 600 500 (OHMS) 1400 1317 1231 1145 1059 973 20 40 60 80 100 120 140 160 180 200 220 C -7 0 10 20 30 40 50 60 70 80 90 100 TEMPERATURE (DEGREES) M10020 Fig. 7. T7047H1008 Remote Sensor resistance change with change in temperature. Wiring IMPORTANT All wiring must agree with applicable codes, ordinances and regulations. Fig. 8 through 16 show schematics and typical connections. Also refer to instructions supplied with other system components. IMPORTANT To avoid electrical interference, which can cause erratic performance, keep wiring runs as short as possible and do not run wires adjacent to the line voltage electrical distribution systems. Use shielded cable (Belden type 8762 or equivalent for 2-wire and Belden type 8772 or equivalent for 3-wire). The cable shield must be grounded only at the controlled equipment case. Fig. 6. T7047G1000 Remote Sensor resistance change with change in temperature. Fig. 8. Internal schematic and typical wiring for T7047C1009. Fig. 9. T7047C1025 connected to W960 or W927 panel with internal setpoint adjustment. Fig. 10. Two T7047C1025 Sensors and one T7047G1000 Sensor providing a temperature-averaging network for a T7300/Q7300 Thermostat/Subbase. 10 20 30 40 50 60 70 80 90 100 710 OHMS AT 75 F (24 C) TEMPERATURE (DEGREES) M5354 -10 0 10 20 30 40 C F110 RESISTANCE F 1093 OHMS AT 75 F (24 C) T1 T2 4 R BW 1 T1 T T M3383 S963B1003 REMOTE SETPOINT POTENTIOMETER M7044 OR M7045 MOTOR TO 24V POWER SUPPLY T7047C t T1 T2 T T M3386 W960 OR W927 PANELT7047C t M3418 T T Q7300 T T T7047C T T T7047C T T T7047G1000 A1 A1 EXCEL 500/100/80 CONTROLLER T7047H COMMON M10019 Fig. 11. Typical wiring for T7047H1008 to Excel 80/100/500/600 Controller. 62-0179 4 T7047C,G,H REMOTE SPACE SENSORS TT1 3 4 2 5 1 T R T R W B Y R SENSOR STAT 24 VAC ECONOC7046A DISCHARGE AIR SENSOR L1 (HOT) L2 W973 LOGIC PANEL 1 C +20 H N 3 2 2 3 4 2 5 6 7 1 8 T T T7067 WALLPLATE T7047C REMOTE SENSOR M3421 T T Q7300 T T T7047G1000T7047G1000 T T Fig. 14. Two T7047G1000 Sensors providing a temperature-averaging network for a T7300/Q7300 Thermostat/Subbase. Q7300 T...
Ce manuel est également adapté pour les modèles :Autres outils - H (196.51 kb)
Autres outils - G (196.51 kb)