Log:
Évaluations - 0, GPA: 0 ( )

Instructions Adaptec, Modèle AEC-7412B

Fabricant : Adaptec
Taille : 874.21 kb
Nom Fichier :
Langue d'enseignement: en
Aller à la télécharger



Par ce dispositif a également d'autres instructions :

Facilité d'utilisation


and cioams.ini files Many of the variables are configured for you once you install the software or start the program. If you are an advanced user and you want to customize your settings, you can edit the variables in the NT registry, or you can open iomgr.ini in a text editor and manually make changes. Adaptec CI/O Management Software User’s Guide I/O Manager Settings The I/O Manager is the portion of the CI/O Management Software which runs on the target system. The I/O Manager provides the run-time intelligence to detect device failures, locate schedules to be run, and send event notifications to clients. The behavior of the I/O Manager may be changed by entries in the iomgr.ini file. [ASPIMODEL] DisableASPI = [Yes | No] I/O Manager options for management of Adaptec SCSI host adapters are configured by certain entries in the standard I/O Manager initialization file (iomgr.ini). The iomgr.ini file is located in the directory where you installed the Adaptec CI/O Management Software. For example, a section headed [ARRAYOPERATIONS] and the variables under each section are described below. [ASPIMODEL] DisableASPI = [Yes | No] This option disables all SCSI Manager functions. This option can be used for problem isolation in I/O Manager systems that support multiple product families (SCSI, RAID). LoadSavedConfiguration= [Yes| No] This option determines whether the ASPI Manager retains configuration information across I/O Manager invocations. The default value for backward compatibility is Yes. When set to Yes, the ASPI Manager will load the last known configuration each time the I/O Manager starts. When set to No, the ASPI Manager will rediscover all host adapters and devices. DiscoveryInterval = n This option configures the frequency (in seconds) that the Discovery phase is run. The default value is 1800 (30 minutes). System design prevents a Poll phase or a Statistics phase from being active when a Discovery phase is activated. PollInterval = n This option configures the frequency (in seconds) that the Poll phase is run. The default value is 180 (3 minutes). If a Poll phase is Configuration Settings activated when a Discovery phase is active, the Poll phase is delayed until the Discovery phase completes. System design prevents a Statistics phase from being active when a Poll phase is activated. StatisticsInterval = n This option configures the frequency (in seconds) that the Statistics phase is run. The default value is 10 (10 seconds). If a Statistics phase is activated when a Discovery phase is active, the Statistics phase is delayed until the Discovery phase completes. System design prevents a Poll phase from being active when a Statistics phase is activated. TapeBusyTolerationTime = n A tape drive may be legitimately busy for extended periods of time (e.g., during a retension operation). On some operating systems, the SCSI Manager has no way to tell the difference between a tape drive device failure and a legitimate temporary unavailability...

Ce manuel est également adapté pour les modèles :
Autres composants - AEC-4412B (874.21 kb)
Autres composants - AAA-131U2 (874.21 kb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories