Instructions ResMed, Modèle Mirage Activa LT

Fabricant : ResMed
Taille : 796.39 kb
Nom Fichier : 5245eba0-9d3f-4633-bfbc-1af03d8e1c1a.pdf
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


Intended Use The Mirage Activa LT channels airflow noninvasively to a patient from a positive airway pressure device such as a continuous positive airway pressure (CPAP) or bilevel system. The Mirage Activa LT is: • to be used by adult patients (>66 lb/30 kg) for whom positive airway pressure has been prescribed • intended for single-patient re-use in the home and multipatient re-use in the hospital/institutional environment. Device Setting Select ‘Activa’ (if available) or ‘Standard’ as the mask option when using the Mirage Activa LT with ResMed devices that have mask setting options. For a full list of compatible devices for this mask, see the Mask/Device Compatibility List on on the Products page under Service & Support. If you do not have internet access, please contact your ResMed representative. 1 2 Parts of the Mask & Ordering Information Forehead support pad 60123 (1) 60124 (10) Upper straps Lower straps *S Small # St Standard Forehead support 16393 Dial 61289 Mask cushion and Clip 60177 (M) 60178 (L) 60179 (LW) Ports cap 16570 (2) 16571 (10) Elbow 16387 Swivel 16565 Mask frame 60180 Cushion clip 60176 Headgear 16118 (S)* 60114 (St)# 16119 (L) Headgear clip 16569 (2) 16734 (10) Complete System Frame System (No headgear) Medium (M) 60148 Medium (M) 60172 Large (L) 60149 Large (L) 60173 Large-Wide (LW) 60150 Large-Wide (LW) 60174 Frame assembly (no headgear, no cushion): 60175 Elbow assembly (elbow, swivel): 16399 3 English Fitting 1 2 3 4 5 6 7 8 4 Disassembly Removal 1 2 3 4 5 6 7 8 9 1 2 English Cleaning the Mask at Home • The mask and headgear should be cleaned by handwashing. • The headgear may be washed without removing the headgear clips. WARNING Do not use aromatic-based solutions or scented oils (eg, eucalyptus or essential oils), bleach, alcohol or products that smell strongly (eg, citrus) to clean any of the mask components. Residual vapors from these solutions can be inhaled if not rinsed thoroughly. They may also damage the mask, causing cracks. CAUTION • If any visible deterioration of a mask component is apparent (cracking, crazing, tears etc.), the mask component should be discarded and replaced. • Avoid connecting flexible PVC products (eg, PVC tubing) directly to any part of this mask. Flexible PVC contains elements that can be detrimental to the materials of the mask, and may cause the components to crack or break. Daily/After Each Use To optimize the mask seal, facial oils should be removed from the cushion after use. Handwash the mask by gently rubbing in warm (86°F/30°C) water using mild soap. If the vent requires cleaning use a soft bristle brush. Rinse all components well with drinking quality water and allow them to air dry out of direct sunlight. Do not soak the mask. Weekly Handwash the headgear in warm (86°F/30°C) water using mild soap. Reprocessing the Mask between Patients This mask should be reprocessed when used between patients. Cleaning, disinfection and sterilization instructions are available from the ResMed website, If you do not have Internet access, please contact your ResMed representative. Storage Ensure that the mask is thoroughly clean and dry before storing it for any length of time. Store the mask in a cool dry place out of direct sunlight. 5 Reassembly 1 2 3 4 5 6 7 10 8 9 1211 6 Troubleshooting Possible reason Solution English Mask is uncomfortable Headgear straps are too tight. Adjust the straps evenly. The forehead support “anchors” your mask and should sit firmly on your forehead. Cushion incorrectly inflated. With the air turned off, adjust the straps so that you can insert two fingers between your cheek and the lower headgear strap. Mask is too noisy Cushion clip is not inserted Check that the cushion clip is correctly inserted correctly. into the cushion, and that the cushion is correctly clipped to the frame. Ports cap or elbow incorrectly Check the the ports cap and elbow are correctly inserted. inserted. Vents are blocked or partially Clean vents according to instructions in blocked. “Cleaning the Mask at Home”. Air leaking around the face Mask not positioned correctly. Reposition the mask upon the face. Air leaking around the bridge of the Wind the dial in. nose. Air leaking around the top of the lip. Wind the dial out. The mask does not fit properly Cushion could be the wrong size. Talk to your clinician. Mask is incorrectly assembled. Reassemble the mask according to the instructions in “Reassembly”. Cushion may be dirty. Clean cushion according to instructions in “Cleaning the Mask at Home”. Cannot insert forehead support into mask frame When assembling the mask, you Push dial base onto a hard surface until the dial have inserted the dial into the frame comes out of the frame. before the forehead support. Disposal The mask does not contain any hazardous substances and may be disposed of with your normal household refuse. 7 Technical Specifications The mask system does not contain lat...


Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories