Log:
Évaluations - 4, GPA: 3.8 ( )

Instructions ResMed, Modèle Positive Airway Pressure Device VPAP IV ST

Fabricant : ResMed
Taille : 301.97 kb
Nom Fichier :
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


Applicable ResMed warranty details are provided with the device at the time of original supply. Of course, as with all electrical devices, if any irregularity becomes apparent, you should exercise caution and have the device inspected by an authorised ResMed service centre. CAUTION ! • Do not attempt to open the VPAP case. There are no user serviceable parts inside. • Inspection and repair should only be performed by an authorised agent. Under no circumstances should you attempt to service or repair the flow generator yourself. Troubleshooting If there is a problem, try the following suggestions. If the problem cannot be solved, contact your equipment supplier or ResMed. Do not attempt to open the device. Problem/Possible Cause Solution No display Power is not connected. Ensure the power cable is connected and the power switch (if available) is on. Insufficient air delivered from the VPAP device Ramp time is in use. Wait for air pressure to build up or change ramp time. Air filter is dirty. Replace air filter. Air tubing is not connected Check air tubing. properly. Mask and headgear are not Adjust position of mask and headgear. positioned correctly. Cushion seated incorrectly Adjust headgear or re-fit cushion. causing excessive leak. Humidifier control dial set too Turn humidifier control down and empty the water from the air high, resulting in accumulation of tubing. water in the air tubing. Device does not start when you breathe into the mask Breath is not deep enough to Take a deep breath in and out through the mask. trigger SmartStart/Stop. There is excessive leak. Adjust position of mask and headgear. Air tubing not connected properly. Connect firmly at both ends. SmartStart/Stop is disabled. Enable SmartStart/Stop. Note: SmartStart/Stop is not available if you are using a Full Face Mask or if Leak Alert is enabled. Device does not stop when you remove your mask SmartStart/Stop is not enabled. Enable SmartStart/Stop. Note: SmartStart/Stop is not available if you are using a Full Face Mask or if Leak Alert is enabled. SmartStart/Stop is enabled but the flow generator does not stop automatically when you remove your mask Incompatible mask system being Use only equipment recommended by ResMed. used. Displays error message: Check tube!! Key if done The air tubing is loose or blocked. Check that the air tubing is connected securely to your mask and the air outlet. Press the Start/Stop key to restart the device. If this does not clear the message, disconnect the power cord and then reconnect it to restart the device. English Troubleshooting Problem/Possible Cause Solution Displays error message: Exxxx Call Service (where xxxx defines an error) Component failure. Record error number and contact your ResMed service centre. Displays error message: HIGH LEAK!!! Adjust Mask You have experienced excessively Check that your air tubing is connected properly. high leak levels for more than 20 Adjust headgear. seconds. The following message is displayed on the LCD after you try to update settings or copy data to the Data Card: Card Error Remove Card Data Card is not inserted Ensure that the Data Card is inserted with the arrow facing up correctly. as far as it can go. You may have removed the Data Reinsert the Data Card and wait for the Settings Success Card before settings were copied Remove Card or Copy Complete Remove Card to the VPAP device. message to appear on the LCD. The following message is displayed on the LCD after you try to update the settings using the Data Card: Settings Invalid Remove Card The identification details on the Contact your clinician/service provider immediately. Data Card do not match the details on your device. The following message is displayed on the LCD after you try to update the settings using the Data Card: Settings Error Remove Card There is a data error on the Data Contact your clinician/service provider immediately. Card. The following message is NOT displayed on the LCD after you try to update the settings using the Data Card: Settings Success Remove Card The settings were not updated. Contact your clinician/service provider immediately. Technical Specifications Operating pressure range 2 to 25 cm H2O Maximum single fault steady 40 cm H2O state pressure Pressure measurement ±0.5 cm H2O ± 4% of the measured reading tolerance Flow measurement tolerance ±0.1 or 20% of reading, whichever is greater S, ST and T modes IPAP: 4 to 25 cm H2O (measured at the mask); EPAP: 2 to 25 cm H2O (measured at the mask); Pressure Support: 0 to 23 cm H2O CPAP mode 4 to 20 cm H2O (measured at the mask) DECLARED DUAL-NUMBER NOISE EMISSION VALUES in accordance with ISO 4871: Sound pressure level 26 dBA with uncertainty of 2 dBA as measured according to ISO 17510-1: 2002 28 dBA with uncertainty of 2 dBA as measured according to ISO 17510-1: 2007 Sound power level 36 dBA with uncertainty of 2 dBA as measured according to ISO 17510-1: 2007 Dimensions (L xW x H) 112 mmx164 mm x 145 mm Weight 1.3 kg Power su...

Ce manuel est également adapté pour les modèles :
Autres appareils personnels - Positive Airway Pressure Device VPAP IV (301.97 kb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories