Facilité d'utilisation
Fits both –A (230) and –C (460) models. • Integral safety switch-shuts light off when upper access door is opened • Bulb Life – 9000 Hours -Recommended continuous operation for maximum bulb and ballast life -Recommended annual bulb replacement for maximum UV effectiveness Page 4 II. INSTALLATION BASIC INSTALLATION 1. Before doing any service work, the unit disconnect must be turned off and locked to prevent injury or death due to electrical shock or contact with moving parts. The thermostat must also be turned off. 2. Unpack the ultraviolet light kit, accessories, and Installation Instructions. 3. On the top of the UV light kit there is an adjustable bracket on the left and right side of the housing (see figure 1). Loosen the screws to right bracket and move the bracket to the specified location using Table 2 and the labels on the back of the UV light assembly. Then tighten the screws. Set aside. Figure 1 Table 2 Wall Mount Unit UV Light width Bracket Position Cabinet Size WA182, WA242, WH183, WH242, WL182, WL242 33-7/8 A 2 WA302, WA372, WH301, WH361 WL302, WL372, WH311, SH311,WH261, SH261 37-7/8 B 3 WA423, WA484, WH421, WH483, WL423, WL484, WH381, WH431, WH491, SH381, SH431, SH491, WA602, WH602, WL602 41-7/8 C 5 WA701, WA721, , WL701, WH611, SH611 41-7/8 C 6 Page 5 Page 6 4. Remove the exterior blower access panel from the wall mount unit and set it aside. (See Figure 2) 5. Using the top screw hole for the blower door panel as a starting point, drill two . inch holes on each side of the unit to secure the mounting brackets of the WUVCLP. See Figure 3 for hole locations. 6. Place the WUVCLP light assembly in the unit 1” below the top of the unit. Insert two self drilling screws on the right side of the unit and into the right side mounting bracket of the WUVCLP light assembly. Use the pilot holes in the mounting brackets for alignment. (See Figure 4) Figure 2 Figure 3 Figure 4 7. Slide the left bracket tight against the left side of the unit. Insert two self drilling screws on the left side of the unit and into the left side mounting bracket of the WUVCLP light assembly. Use the pilot holes in the mounting brackets for alignment. Tighten the . in screw on the left side bracket to hold in place. (See Figure 5) 8. Unpack the WUVCLP light bulb and insert the plug end through the hole closest to the wire connection. Then insert the other end of the bulb through the other end bracket. When the bulb is in place use the clamp to secure the bulb and connect the wire plug to the light bulb. 9. Use the alcohol wipe to clean any oil or dirt deposits off the UV light bulb. Oils from human skin will reduce the effectiveness of the UV light bulb WIRING 230/208 Volt Single Phase and Three Phase Units Only 1. For 230/208 volt single phase and three phase units run the flexible conduit and wires down through the blower partition in the same opening that the copper tubing goes through. Use wire ties to secure the conduit to the suction line. See Figure 6A & 6B. Figure 5 Figure 6A Figure 6B Page 7 2. Remove outer and inner control panel covers. Install the 3 pin accessory plug from the parts bag into the control panel if not already equipped. See figure 7A for side installation on the 5 or 6 ton cabinet size. See figure 7B for back installation on the 2 1-480701-0 cap as shown Install 1-480701-0 cap as shown and 3 ton cabinet size. Install Figure 7A Figure 7B 3. Plug the WUVCLP light into the 3 pin accessory plug just installed. Plug located on the side or back of the control panel. 460 Volt Three Phase Only 1. Remove the transformer cover and set aside. Place the transformer assembly on the left side of the blower partition. Remove the back screw holding the blower partition to the side angle. Place the back left corner of the transformer box over this hole and reinstall screw. Use an additional self-drilling screw to secure the front right corner of the transformer box. (See Figure 8) 2. Run the flexible conduit across the back of the blower partition and down through the blower partition in the same opening that the copper tubing goes through. Use wire ties to secure the conduit to the suction line. (See Figure 6B) Figure 8 Page 8 3. Remove outer and inner control panel covers. Install the 3 pin accessory plug from the parts bag into the control panel if not already equipped. See figure 6A for side installation the 5 or 6 ton cabinet size. See figure 6B for back installation on the 2 and 3 ton cabinet size. 4. Plug the WUVCLP light into the 3 pin accessory plug just installed. Plug located on the side or back of the control panel. Secure mounting bracket to control panel with screws provided. 5. Route the flexible conduit from the light across the blower partition and into the transformer box. Secure the conduit to the box with the fitting supplied. (See Figure 9) Figure 9 6. Remove the nut securing the transformer foot to the box and connect the ground wire to this bolt. Reinstall the nut. Connect the black wire from the ...
Ce manuel est également adapté pour les modèles :Autres appareils personnels - WUVCLP-A (1.43 mb)