|
Facilité d'utilisation
Select a Location WARNING NEVER block the air openings of the product or place it on a soft surface, such as a bed or couch, where the air opening may be blocked. Keep the openings free from lint, hair and the like. Keep unit at least 3 inches away from walls, draperies, furniture, and the like. You may select a room where using your oxygen concentrator would be most convenient. Your concentrator can be easily rolled from room to room on its casters. Your oxygen concentrator will perform best when operated under the following conditions. Refer to Typical Product Parameters on page 12. Usage in environments other than those described may result in the need for increased equipment maintenance. The air intake of the unit should be located in a well ventilated area to avoid smoke, airborne pollutants and/or fumes. DO NOT place in a closet. Part No 1143482 15 Perfecto2 ™Series SECTION 5—OPERATING INSTRUCTIONS Set Up Plug in Power Cord Plug in power cord to an electrical outlet. Connect Humidifier (If So Prescribed) WARNING DO NOT overfill humidifier. DO NOT reverse the oxygen input and output connections. Water from the humidifier bottle will travel through the cannula back to the patient. NOTE: For this procedure, refer to FIGURE 5.1, FIGURE 5.2 on page 17, FIGURE 5.3 on page 18. 1. Remove cap from bottle. 2. Fill humidifier with distilled water to the level indicated by the manufacturer. Replace the humidifier cap and securely tighten. Humidifier Humidifier Bottle w/o Cap Bottle with Cap FIGURE 5.1 Filling the Humidifier 3. Insert a flathead screwdriver in the plate groove on the top edge of the filter access door and gently pry the filter access door off (FIGURE 5.2). 4. Pull up and remove the humidifier bottle adapter (FIGURE 5.2). Perfecto2 ™Series 16 Part No 1143482 SECTION 5—OPERATING INSTRUCTIONS Part No 1143482 17 Perfecto2 ™Series FIGURE 5.2 Humidifer Bottle Adapter 5. Attach the humidifier bottle adapter to the humidifier bottle by turning the wing nut on the humidifier bottle counterclockwise until it is securely fastened. See Detail “A” in FIGURE 5.3. 6. Place the humidifier bottle/adapter assembly in the humidifier compartment on the concentrator. See Detail “B” in FIGURE 5.3. 7. Attach oxygen tubing from the humidifier bottle/adapter assembly to oxygen outlet connector on the concentrator. See Detail “B” in FIGURE 5.3. 8. Attach the cannula/patient supply tubing to the humidifier bottle outlet. See Detail “B” in FIGURE 5.3. 9. After assembly, ensure that oxygen is flowing through the cannula. Filter Access Door Cabinet Filter Humidifier Bottle Adapter Insert Flat Head Screwdriver Here SECTION 5—OPERATING INSTRUCTIONS Perfecto2 ™Series 18 Part No 1143482 FIGURE 5.3 Humidifier Compartment Power Switch NOTE: For this procedure, refer to FIGURE 5.4. 1. Press power switch to on position. All the panel lights and the audible alarm will come on for one second, indicating that the unit is functioning properly. FIGURE 5.4 Power Switch Humidifier Bottle Humidifier Compartment Humidifier Bottle Adapter Humidifier Bottle DETAIL “A” DETAIL “B” Oxygen Tubing Oxygen Outlet Connector Humidifier Bottle Outlet On/Off (I/O) Power Switch SECTION 5—OPERATING INSTRUCTIONS Flowrate NOTE: For this procedure, refer to FIGURE 5.5 on page 20. 1. Turn the flowrate knob to the setting prescribed by your physician or therapist. CAUTION Never set the flow greater than 5 L/min. WARNING DO NOT change the L/min setting on the flowmeter unless a change has been prescribed by your physician or therapist. NOTE: To properly read the flowmeter, locate the prescribed flowrate line on the flowmeter. Next, turn the flow knob until the ball rises to the line. Now, center the ball on the L/min line prescribed. 2. If the flowrate on the flowmeter ever falls below 0.5 L/min for more than about one minute, the LOW FLOW alarm will be triggered. This is a rapid beeping of the audible alarm. Check your tubing or accessories for blocked or kinked tubing or a defective humidifier bottle. After rated flow is restored, between 0.5 L/min and 0.75 L/min, the LOW FLOW audible alarm will turn off. NOTE: The use of some accessories such as the pediatric flowstand and the HomeFill compressor will deactivate the Low Flow Alarm. Part No 1143482 19 Perfecto2 ™Series SECTION 5—OPERATING INSTRUCTIONS Perfecto2 ™Series 20 Part No 1143482 FIGURE 5.5 Flowrate Front Panel Indicators - Units with SensO2 The SensO2 feature monitors the purity of oxygen generated by the oxygen concentrator. If purity falls below factory preset standards, indicator lights on the control panel will illuminate. FIGURE 5.6 Front Panel Indicators - Units with SensO2 Flow Knob Ball Flowmeter Front Panel 0.5 L/min O2 Auto Shut Down Use Backup Below Normal Normal RED Call Supplier YELLOW GREEN OXYGEN PURITY SECTION 5—OPERATING INSTRUCTIONS Initial Startup of the Concentrator NOTE: Concentrator may be used during the initial start warm.uptime (approximately 30 min.) while waiting for the O2...
Ce manuel est également adapté pour les modèles :Autres appareils personnels - IRC5PO2W (1.57 mb)