Log:
Évaluations - 3, GPA: 4 ( )

Instructions InFocus, Modèle SP-CEIL-UNIV

Fabricant : InFocus
Taille : 583.13 kb
Nom Fichier : 5b2af94f-f1a9-4d14-a1d3-93a0b5851073.pdf
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


Read instruction sheet before you start installation and assembly. WARNING • Make sure that the supporting surface will safely support the combined load of the equipment and all attached hardware and components. IMPORTANT! Turn to the appropriate page for your ceiling installation. Applications: Flush Mount ................................................................................................................................................. page 5 Extension Column ........................................................................................................................................ page 6 Lightweight Suspended Ceiling Plate ....................................................................................................... page 7 Installations: To Wood Joist Finished Ceilings, Exposed Wood Joists, or Wood Beam Ceilings ........................................................................................ page 3 To Concrete Ceilings.................................................................................................................................... page 4 1 of 11ISSUED: 10-22-04 SHEET #: 055-9236-5 01-10-06 Visit the InFocus Web Site at Parts List Before you start check the parts list to insure all of the parts shown are included. Description Qty. Parts List Before you start check the parts list to insure all of the parts shown are included. Description Qty. A projector mount assembly 1 055-0420 B 4 mm security allen wrench 1 560-9646 C #10-32 x 3/8" serrated socket pin screw 2 520-1151 D #10-32 x 1/4" socket pin screw 1 520-1196 E 1/4" flat washer 2 540-9440 F #14 x 2.5 phillips hex head wood screw 2 5S1-015-C03 G concrete anchor 2 H M4 x 16 mm serrated socket pin screw 3 I M4 x 12 mm serrated socket pin screw 1 590-0097 510-1087 510-1079 J .198 x .313 x .375 retaining spacer 3 590-2020 K .198 x .313 x .187 retaining spacer 1 590-1030 L .25" ID x .56" OD x .26" spacer 6 590-1050 M M5 x 10 mm socket pin screw 1 520-1164 N #10-32 x 3/16" slotted set screw 1 520-1187 O M6 x 12 mm serrated socket pin screw 4 510-1050 P M4 x 6 mm serrated socket pin screw 2 510-1059 Q ceiling plate 1 580-1042 R adapter plate 1 055-1539 S extension bracket 2 055-1540 A Q Note: Actual parts may appear slightly different than illustrated. FASTENERS R O P S B C F LJ K M N D E G IH 2 of 11 ISSUED: 10-22-04 SHEET #: 055-9236-5 01-10-06 Visit the InFocus Web Site at CONNECTION BLOCK CAPTIVE SCREW A Installation To Wood Joist Finished Ceilings, Exposed Wood Joists, or Wood Beam Ceilings Drill two 5/32" (4 mm) dia. holes to a minimum depth of 2.5" (64 mm). Attach ceiling plate (Q) with two #14 x 2.5" (6 mm x 65 mm) wood screws (F) as shown using 3/8" (10 mm) socket wrench. Tighten wood screws (F) so ceiling plate (Q) is firmly attached. WARNING • Tighten wood screws so that ceiling plate is firmly attached, but do not overtighten. Overtightening can damage the screws, greatly reducing their holding power. • Never tighten in excess of 80 in • lb (9 N.M.). • Make sure that mounting screws are anchored into the center of the joist. The use of an "edge to edge" stud finder is highly recommended. F F Q WOOD JOIST CEILING Skip to step 7. For optional Cord Management, install two spacers (L) between ceiling plate (Q) and ceiling. WOOD JOIST CEILING F F Q L L 3 of 11 ISSUED: 10-22-04 SHEET #: 055-9236-5 01-10-06 Visit the InFocus Web Site at ISSUED: 10-22-04 SHEET #: 055-9236-5 01-10-06 Visit the InFocus Web Site at 4 of 11 Drill two 1/4" (6 mm) dia. holes to a minimum depth of 2.5" (64 mm). Attach ceiling plate (Q) using two concrete anchors (G) and #14 x 2.5" wood screws (F) as shown in Illustration A and 1, 2, and 3. Tighten all fasteners. Skip to step 7. F Illustration A Installation to Concrete Ceilings Alligator® concrete anchors are recommended. Q 1 3 Drill hole and insert anchor. concrete ceiling F F 2 Q CUTAWAY VIEW CONCRETE CEILING • Concrete anchors are not intended for attachment to concrete wall covered with a layer of plaster, drywall, or other finishing material. If mounting to concrete wall covered with plaster/drywall is unavoidable, plaster/ drywall (up to 5/8" thick) must be counterbored as shown below. If plaster/drywall is thicker than 5/8", custom fasteners must be supplied by installer. WARNING G • Make sure that the supporting surface will safely support the combined load of the equipment and all attached hardware and components. • Tighten concrete anchor bolt firmly, but do not overtighten. Overtightening can damage the bolt, greatly reducing its holding power. • Never tighten in excess of 80 in • lb (9 N.M.). WARNING G G G Place ceiling plate over anchor and secure with screw. After repeating step one tighten all fasteners. INCORRECT metal concrete bracket plaster/ dry wall CORRECT concrete metal bracket plaster/ dry wall Flush Mount Installation Flush Mount Installation WARNING • Tighten wood screws so that pro...


Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories