Log:
Évaluations - 1, GPA: 3 ( )

Instructions Chamberlain, Modèle OTIUEX

Fabricant : Chamberlain
Taille : 77.7 kb
Nom Fichier : otiuex.pdf
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


NOTE: If programming into an existing network, ensure that the OTIUEX is programmed to the Active unit. 2 Features & Operation Answering Calls (Regular Mode) When visitor presses the Call button on intercom, the telephone connected to the OTIUEX will ring distinctively up to four times. If an expandable OTIUEX system is used all phones within the system will ring. When the phone is answered it will connect to the Intercom at gate or door. After connecting to the Intercom, the gate can be activated by dialing “*9”. To activate the primary gate operator dial “*9” on the phone connected to the OTIUEX. Caller ID When there is a visitor at the gate the OTIUEX will display “Gate Visitor” on a Caller ID telephone (or Caller ID box) that is directly connected to it. When there is a visitor at the door, the OTIUEX will display “Front Door” or “Back Door” depending on howyou have your door Intercom set up (see Intercom manual). If someone is tampering with the gate, the OTIUEX will ring the phone and display “!Gate Tamper!”. Call Waiting When talking on the phone connected to OTIUEX, a distinctive beep will be heard indicating Call Waiting. Caller ID will alert that there is a visitor. To place call on hold and connect to the Intercom, press the FLASH button. When talking on phone other than the one connected to the OTIUEX, the telephone connected to the OTIUEX will ring as normal and the call will not be interrupted. Change Number of Rings By default the OTIUEX will ring the telephone 4 times. If an answering machine is programmed to pick up after 4 rings, OTIUEX should be changed to ring 3 times. This will prevent the answering machine from picking up if phone is not answered when a visitor calls. If the answering machine does pick up, visitor will hear answering machine message through speaker. Using the telephone connected to OTIUEX, dial :**102 for 2 rings up through “**105” for 5 rings. Call Forwarding If user is away from home the OTIUEX can be programmed to call when there is a visitor. When visitor presses Call button the OTIUEX will ring home telephone 1 time. If telephone is not answered, the OTIUEX will dial call-forwarding number that has been programmed. After ringing that number 3 times the OTIUEX will hang up. If visitor presses Call button again the process will repeat. Programming Call Forwarding Number On telephone connected to OTIUEX, dial “*#”. A beep will be heard. Enter the forwarding number (up to 14 digits). To accept new number, press “#”. A beep will be heard. NOTE: For long distance calls, include proper prefix. Verifying Call Forwarding Number On telephone connected to OTIUEX, dial “**06”. A beep will be heard. Hang up the telephone. The telephone will ring and the call forwarding number that has been programmed will be displayed on Caller ID screen. Enable/Disable Call Forwarding To enable call forwarding dial “**01” on telephone connected to OTIUEX. A beep will be heard. To disable call forwarding dial “**02” on telephone connected to OTIUEX. A beep will be heard. Remote Activation Through Answering Machine Gate can be remotely activated through the answering machine. Call home and when answering machine picks up, dial “*9”. The OTIUEX will then activate the gate. NOTE: Any features of the OTIUEX do NOT require extra service from the Telephone Company. Answering Calls (Call Forwarding Mode) When answering call from OTIUEX, a beep will be heard for up to 10 seconds. To accept call, dial “0”. Hang up to disconnect. To control the gate dial “*9”. NOTE: OTIUEX checks if home line is busy prior to dialing forwarding number. If busy, the OTIUEX will wait and try again. Once OTIUEX dials forwarding number, if forwarding number is busy, the OTIUEX will wait and try again. 3 Troubleshooting Dial tone is not heard after connecting to the OTIUEX. Check phone connections. If it is a two-line phone ensure it is on Line 1. If a dual-tone error tone is heard when trying to open gate, ensure OTIUEX is programmed to the correct GAPLM, DAILM, or Intercom. Check that gate operator has been taught to master unit as well. If OTIUEX has already been programmed and will need to have memory cleared (see below). When dialing numbers a dial tone is heard. All numbers and symbols must be dialed within 3 seconds of each other, otherwise the OTIUEX times out and returns to dial tone. Memory needs to be cleared. Clearing OTIUEX memory will not clear any OTIUEX settings or programmed phone numbers. To clear memory, dial “**#8” on the telephone connected to the OTIUEX. A beep will be heard. To clear DAILM memory, set Dipswitch #1 to the DOWNposition, then press the Learn button until a beep is heard (about 15 seconds). OTIUEX is not getting expected transmission range. When used in buildings with stucco or cement walls, the range is greatly reduced. The Repeaters can be used close to the building to solve this problem. Keep OTIUEX away from trees, metal objects, masonry, computers, and any other “Radio Noise Source”. ...

Ce manuel est également adapté pour les modèles :
Téléphones filaires - OTIUEX (77.7 kb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories