6. Remove brush spacer and brush by sliding off of brush shaft(figure 17). 7. Rotate brush or replace. 8. Slide brush on shaft and rotate slowly until drive pins arelined up with brush slots. Push brush all the way in. 9. Install brush spacer on shaft. 10. Slide brush door bearing assembly on shaft. 11. Raise door and install thumb screw. DANGER: Operating a machine that is not completelyor fully assembled could result in injury orproperty damage. Do not operate thismachine unless it is completely assembled. Inspect the machine carefully beforeoperation. Figure 14A Figure 14B Figure 15 Figure 17 Figure 16 CLARKE TECHNOLOGY Operator's Manual - Encore L26 Cylindrical Page -15 How To Operate The Machine DANGER: Operating a machine that is notcompletely or fully assembled couldresult in injury or property damage. Do not operate this machine unless itis completely assembled. Inspect the machine carefully before operation. How To Operate The Squeegee The squeegee wipes the floor while the vacuum motor removes the dirty solution from the floor. Use your hand to lower or raise the squeegee handle. To operate the squeegee, follow this procedure: 1. To lower the squeegee and start the vacuum motor, move the squeegee lever to the right and down. See figure 18. 2. To raise the squeegee, lift the squeegee lever up. See figure 19. NOTE: The center position lets the vacuum motor continue to run with the squeegee off the floor to avoid drips and also allows you to back up the machine. How To Fill The Solution Tank The solution tank can be filled in the front or through the clear drain hose at the rear of the machine (See figure 20). To fill the solution tank follow this procedure: 1. Add a cleaning chemical to the solution tank. For the correct amount of chemical, follow the directions shown on the container. 2. Fill the solution tank with water. When filling machine in the front with a hose, position hose inside the fill screen as shown in figure 20A. When filling machine from the rear, position clear drain hose against bracket and insert hose as shown in figure 20B Solution level can be viewed from the back of the machine. WARNING: Water solutions or cleaning materials used with this type of machine can leave wet areas on the floor surface. These areas can cause a dangerous condition for the operator or other persons. Always put CAUTION signs near the area you are cleaning. WARNING: Machines can ignite flammable materials and vapors. Do not use with or near flammables such as gasoline, grain dust, solvents and thinners. Only use a cleaning concentration recommended by the chemical manufacturer. WARNING: Clarke Technology recommends a maximum water temperature of 120oF (49oC). Figure 18 Figure 19 Figure 20A Figure 20 Page -16- CLARKE TECHNOLOGY Operator's Manual -Encore L26 Cylindrical How To Operate The Machine How To Operate The Machine Operating The Machine NOTE: Put the machine in the lowest traverse speedsetting. Use the machine in an area that has no furniture or objects until you can do the following: 1. Move the machine in a straight direction, forward andbackward. 2. Stop the machine safely. 3. Turn the machine both left and right and return to a straightdirection. To move the machine, follow this procedure: 1. Release the parking brake (if equipped with machine). 2. Turn the key switch to the "ON" position 3. Raise the brush to the highest setting. 4. Raise the squeegee. 5. When either the left or right forward/reverse switches(figure 21, item A) are pushed in, the machine will goforward. 6. Control the speed of traverse by using the traverse speedcontrol knob (figure 21, Item C). 7. To stop, release the forward/reverse switch. 8. To reverse the machine, push in the white reverse switch(figure 21 item B) and either the right or left forward/ reverse switch (figure 21 item A) at the same time. 9. To stop, release the forward/reverse switch. 10. To turn the machine, push the rear of the machine to theside. 11. When you stop the machine, turn the key switch "OFF", remove the key and set the parking brake (if equipped). How To Clean A Floor WARNING: Water solutions or cleaning materialsused with this type of machine canleave wet areas on the floor surfaces. These areas can cause a dangerouscondition for the operator or other persons. Always put CAUTION signsnear the area you are cleaning. To clean a floor follow this procedure: 1. Set the parking brake (if equipped with machine.) 2. Put the water and a cleaning chemical in the clean solution tank. 3. Release the parking brake (if equipped with machine.) 4. Turn the key switch "ON". 5. Lower the squeegee. 6. Activate the brush switch until correct pressure is achieved. Figure 20B BC AA Figure 21 CLARKE TECHNOLOGY Operator's Manual - Encore L26 Cylindrical Page -17 WARNING: This machine is capable of maximum head pressure with worn brushes. With How To Operate The Machine (cont) How To Operate The Machine (cont) this feature, there is the possibility of exceeding the ...


Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories