Log:
Évaluations - 1, GPA: 4 ( )

Instructions Alto-Shaam, Modèle DX 865

Fabricant : Alto-Shaam
Taille : 1.89 mb
Nom Fichier :
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


Ensure an adequate supply of fresh air. If the machine is to be connected to a flue gas stack, the state building regulations must be observed. We will be glad to provide tips for connection systems, on request. The machine must be supervised at all times so that the operator can notice when the flame goes out. Secure the machine with the parking brake (Fig. 2). Check the oil level in the high-pressure pump (Fig. 3). Fill the cleaning agent tank with prediluted Alto cleaning agent. With the machine cold: Pour fuel (fuel oil EL, biodiesel E to DIN 51 606 or diesel fuel to DIN 51 603) into the fuel tank. The fuel must be free from contamination. – Tank capacity: 30 litres 1) Option / model variants 9 DX 845 W / DX 865 / DX 985 / TitanEnergy / TitanEnergy X GB Unsuitable fuels must not be used as they can represent a source of danger. +At temperatures below 8° C, the fuel oil begins to solidify (paraffin precipitation). This can lead to difficulties in starting the burner. Before the winter period either add a solidification point / flow improver (available from the fuel oil trade) to the fuel or use winter diesel fuel. Fill the tank for the Alto automatic scale alarm system. "Alto Anti-Stone" prevents any deposits of scale and acts at the same time as a corrosion inhibitor. Use the bottle supplied with the pack for filling (Fig. 4). For compatibility reasons, use only the tested "Alto Anti-Stone". Order the refill pack 6 x 1000 ml, No. 8466, in good time. Screw the high-pressure hose firmly onto the VarioPress trigger gun1), pushing back the slide of the locking pin (Fig. 5/ 1 + 5/2). Securely tighten the screw of the Roto-Fix high-pressure spray lance, at the same time pushing back the slide of the locking pin (Fig. 5/3 + 5/4). Connect the water hose (Fig. 6). The use of a fabric-reinforced water hose with a nominal diameter of at least 1/2" (13 mm) is recommended. Connect the high-pressure hose to the high-pressure connection. Ensure that the union nut is securely tightened (Fig. 7)! Turn on the water tap. Insert the plug of the cleaner into the plug socket. STARTING OPERATION RTING OPERATION +The pipework of the machine is filled with antifreeze. Collect the first liquid (approx. 5 litres) which comes out of the spray gun in a suitable vessel for further use. COLD WATER OPERATION Release the lock of the trigger gun and press the trigger (Fig.8). Turn the operating mode switch to position . -> The function test of the displays on the operating panel starts. – All the indicator lights come on briefly, then the indicator light comes on continuously to indicate that the machine is ready for operation. Operate the trigger of the trigger gun several times at short intervals to bleed the system. HOT WATER OPERATION Select the temperature (20- 100° C). Release the lock of the trigger gun and press the trigger (Fig.8). Turn the operating mode switch to position . When a steady jet emerges from the high-pressure nozzle, turn the operating mode switch to position . Using a special device1), the condensate coming out of the heat exchanger can be collected and disposed of in accordance with the local sewage regulations; water poured in and emerging at the nozzle then has the same composition. STEAM OPERATION (OVER 100° C)1) Replace the standard highpressure nozzle with the steam spray nozzle (No. 6692)1). Set the thermostat to a temperature of above 100° C. Turn the rotary knob on the safety control block completely to the left (anticlockwise direction) (Fig. 9). Release the lock of the trigger gun and press the trigger. Turn the operating mode switch to position When a steady jet emerges from the steam spray nozzle, turn the operating mode switch to position . OPERATION OF THE ROTOFIX HIGH-PRESSURE SPRAY LANCE The RotoFix high-pressure spray lance allows the spray lance to be turned for pressure-free operation: Push back the slide of the locking pin (Fig. 5). Turn the screw fitting of the RotoFix high-pressure spray lance until the pin engages in the next bore. OPERATION OF THE COAXIAL SPRAY LANCE1) The working pressure can be steplessly varied by turning the handle of the spray lance, but with a constant volume of water (Fig. 10). OPERATION OF THE PRESSURE AND WATER VOLUME CONTROLLER DX 845 W: The rotary knob on the safety control block allows the pressure and water volume to be steplessly varied (Fig. 9). DX 865, DX 985, TitanEnergy, TitanEnergy X: Stepless variation of pressure and water volume Continuous operation = Rotary knob on the safety control block (Fig. 9). Brief operation = Rotary knob on the VarioPress trigger gun1) (Fig. 11). The set pressure can be read off from the pressure gauge. USE OF CLEANING AGENTS Predilute cleaning agents as described under "General" and pour into the cleaning agent tank. Set the desired concentration of the cleaning agent (table, see section "General") at the metering valve (Fig. 12). Spray the object to be cleaned. Allow the cleaning agent to 1) Op...

Ce manuel est également adapté pour les modèles :
Aspirateurs - DX 845 W (1.89 mb)
Aspirateurs - DX 985 (1.89 mb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories