Replacing the dustbag The "dustbag full indicator" will indicate when the dustbag is full (fig. 20). -Switch the vacuum cleaner off (fig. 16). -Remove the hose (fig. 1b). -Open the cover (fig. 21). -Remove the cassette with the full dustbag (fig. 22). -Remove the full dustbag from the cassette by pulling the cardboard tag (fig. 23). This automatically closes the dustbag. -Discard the full dustbag. -Slide the cardboard front plate of the new dustbag into the two slots of the cassette as far as possible (fig. 24-25). -Position the cassette with the new dustbag (fig. 26). -Bend the rear part of the dustbag downwards. -Close the cover ("Click!") (fig. 27). Note: If no dustbag has been placed into the cassette, the cover cannot be closed. Replacing the “Active Carbon” filter After having removed the full dustbag, you can see the removable holder with the “Active Carbon” filter. This filter contains active carbon to remove unpleasant smells and AFS filter layers for optimum air cleaning. Replace this filter at least once a year (fig. 28-30). You can take the holder to the dustbin and shake the filter out there. Hygienic: you need not touch the filter. New filters can be ordered from your dealer under type number HR 6949 or service number 4822 480 20145. When positioning the holder with the new filter, press firmly into place so that it fits correctly at the bottom. Replacing the AFS-Micro filter The indicator will help you determine if the AFS- Micro filter needs replacing (fig. 31). One new AFS-Micro filter is supplied with each set of original Philips dustbags Oslo+ (type nr. HR 6938 or servicenr. 4822 015 70049) or Oslo+ Hygiene (closeable) (type nr. HR 6938-OSH or service nr. 4822 015 70057). See figs. 32-33 on how to proceed. -Position the lower edge of the new filter properly behind the ridges of the holder. -When closing the holder, ensure that the filter fits in completely. Replacing the mains cord If the mains cord of this appliance is damaged, it must only be replaced by Philips or their service representative, as special tools and/or parts are required. For U.K. only: Fitting a different plug This appliance is fitted with a BS 1363 13 Amp. plug. Should you need to replace the plug, connect the wires as follows: Brown wire to the Live (L) terminal of the new plug. Blue wire to the Neutral (N) terminal of the new plug. Always fit the same value of fuse as that originally supplied with your appliance. Only use BS 1362 approved fuses. As a guide only: Appliances under 700 W can have a 3 Amp. fuse (red) and all others should have a 13 Amp. fuse (brown). When disposing of an old plug (particularly the moulded type which has been cut from the mains cord) always remove the fuse as the plug could be dangerous if ever inserted in a live socket. Before cutting the plug off, temporarily tie a knot in the mains cord to prevent it being inadvertantly drown into the cordwinder. After fitting the new plug, untie this knot. Obtaining dustbags / filters In case you have any difficulties obtaining dustbags or accessories for this vacuum cleaner, please either phone 01480 493 000 or write to: MPP Marketing Ltd., P.O. Box 40, St. Ives, Huntingdon, Cambridgeshire. PE17 4XS. 5 Francais • Pour permettre le recyclage, les plastiques du produit ont ete codifies. • Le carton de l'emballage est compose f de materiaux recycles et entierement recyclables. Important • Avant d'utiliser l'appareil pour la premiere fois, verifier si le sac a poussiere est dans la bonne position. • N'aspirez jamais de l'eau (ou tout autre liquide). N'aspirez jamais de cendres avant qu'elles ne soient completement froides. • La poignee est le tuyau contiennent des conducteurs electriques. Pour eviter tout probleme : -Ne les nettoyez jamais avec de l'eau -N'aspirez pas d'objets tranchants -Verifiez regulierement que le tuyau et la poignee ne soient pas endommages. -Remplacez immediatement tout tuyau ou poignee endommage. • Lorsque vous aspirez de la poussiere tres fine (platre, cendres, etc), les pores du sac a poussieres peuvent s'obstruer. Cela reduit le passage de l'air. Ensuite, le sac a poussieres doit etre change, bien qu’il soit a moitie plein. • Utilisez uniquement l'aspirateur avec le sac papier double epaisseur sans addition de chlore type Philips Oslo+ ou Oslo+ Hygiene (fermable). • N'utilisez jamais l'aspirateur sans le filtre a charbon actif. Utilisation • Raccordez le flexible: pressez fermement ("Clic!") (fig. 1a). - Pour le retirer: pressez le bouton et tirez sur le tuyau (fig. 1b). • Assemblez le suceur, les tubes et la poignee: inserez la section retrecie dans la section la plus large (fig. 2). • Ajustez le tube telescopique a la longueur desiree (fig. 3). Suceurs -Suceur combine. Ce suceur est convertible et peut etre utilise sur moquettes ou tapis (sans brosse, fig. 4) ou sols durs (avec brosse, fig. 5); - Petit suceur, suceur brosse, suceur long se trouvent dans le compartiment de rangement (fig. 6-10). • Tirez la fiche hors de l'aspi...


Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories