Log:
Évaluations - 3, GPA: 3.7 ( )

Instructions B&K, Modèle AVR515

Fabricant : B&K
Taille : 6.3 mb
Nom Fichier : 664d8979-e232-3154-4d82-242304105f1a.pdf
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


To configure the V1 output see page 33. ZB / V2 Out - The V2 output can be configured as an output for a second recording device in Zone B or as a Zone B line output to connect a second video monitor and/or audio amplifier. As a record output, V2 will output the analog audio and video from the selected input in Zone B except when V2 is selected. This prevents feedback through the recording device which could damage your speakers. As a line output V2 will output the analog audio and video from whatever input is selected in Zone B. Record/Line settings also apply to the Zone B optical and coaxial digital outputs. As with the Tape output, digital audio is not converted to analog on the V2 output. Nor is video transcoded on the V2 output. To configure the V2 output, see page 38. CONTROL OUTPUT CONNECTIONS The B&K surround receiver is supplied with four control outputs. These control outputs can be used for a variety of applications that require a 12 volt control or an IR output (pass through). The control outputs use a 1/8” (3.5mm) mono mini plug. Each output is 10-12VDC @ 50 mA. Control output 1 is strictly a +12VDC control trigger. Control outputs 2-4 can be set up as either +12VDC controls or as an IR pass through. To configure the control outputs, see the control setup section on page 35. IR Emitter Connection To connect an IR emitter to the control output, one end should be terminated into a 3.5mm mono mini plug, tip (+), sleeve (-). The IR output will pass through IR signals received by the surround receiver. Only industry standard 38kHz IR can be used with the IR outputs. Additional resistance may be required in series with the IR emitter, check the current rating of the emitter you are using. 18 L Audio/Video Systems Hand-Made in the U.S.A. SURRND FRONT SUB CENTER + ZB/V2 V1 TAPE TAPE SAT CD DVD TV V2 V1 IN 1 IN 2 IN 3 DVD INPUT A/V SOURCE OUTPUTS A/V SOURCE INPUTS COMPONENT VIDEO AM FM ANTENNA ZONE A ZONE B OUTPUTS SURRND FRONT S BACK ZONE B SUB CENTER SURROUNDOUTPUTS COAX S/PDIF DIGITAL OPTICAL S/PDIF DIGITAL ZA OUT TV V2 V1 OUT SAT CD DVD V2 V1 ZB OUT SAT CD DVD CONTROL OUT IR INPUT ZONE A IEEE 1394 12VDC 50 mA 1 2 3 4 OUTPUT IR INPUT ZONE B AUDIO RS-232 PORT PLAY 8:33 +12VDC Control Connection If the +12VDC trigger is going to be used, it should be connected as shown right. An external amplifier is being used for this example, however the external device could be any device that employs a control trigger circuit. The plug must be wired as tip (+) and the sleeve (-). The diagram at right shows a B&K amplifier controlled with the +12Volt control. ZONE B CONNECTIONS Your B&K receiver is capable of controlling a second independent analog audio and composite video or Svideo zone This second zone could encompass a small room or large area depending on how much amplification is supplied. The second zone is strictly analog audio, composite video and/or S-Video. There is no transcoding for Zone B. The composite video and analog (stereo) audio must be connected to the receiver in order to be seen and heard in the second zone. Control for the second zone can be accomplished by using a remote control or by connecting a CK1.2 Keypad. See page 21 for keypad connection description. The audio and video output signals are connected from the Zone B outputs on the back panel of the receiver to a Zone B video monitor and a Zone B amplifier. Zone B Amplification and Video Connection To connect an amplifier for Zone B (second zone) audio, connect RCA type audio cables between the Zone B left and right output to the second zone amplifier. Connect the second zone video cable to the Zone B composite or S-video output to the Zone B video monitor. The Zone B audio output can be configured fixed or variable. The second zone has the ability to link power and/or source input to the main theater zone. From the factory, the second zone is configured as a separate, independent audio and video zone. The figure below shows a B&K Reference 200.2 supplying power for the second zone. To configure the Zone 2 settings, see page 38. 19 Zone B amplifier AVR 515 Series 2 AVR517 Series2 BACK CHANNEL AMPLIFICATION CONVERSION If both zones of the AVR517 Series2 are being used, you have the option of either using an external amplifier (see page 19) or converting the surround back channels to supply the amplification for Zone B. The main theater zone would then become a 5.1 surround system. This modification can be ordered directly from the factory, or you may contact you local B&K dealer. If you any questions about converting the AVR517 Series2 receiver for Zone B amplification, please contact customer service at 716-656-0026 M-F 8:30 - 5:30 EST. 20 AVR 517 Series 2 KEYPAD CONNECTION DESCRIPTION To connect a CK1.2 Keypad to the AVR515 Series2 or 517 Series2, run a straight through Category 5 (CAT5) cable from the keypad location to the RS-232 jack on the receiver back panel. Terminate both ends of the CAT5 cable into RJ-45 using the T568B standa...

Ce manuel est également adapté pour les modèles :
Récepteur et amplificateur - AVR517 (6.3 mb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories