Log:
Évaluations - 3, GPA: 3.7 ( )

Instructions Crestron electronic, Modèle IM-RXV3-M

Fabricant : Crestron electronic
Taille : 1.21 mb
Nom Fichier : io_im-rxv1-m_im-rxv3-m.pdf
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


Other high-quality/low skew CAT5e/CAT6 wiring may also be used with varying performance. Hardware Connections (Rear) 123GPOWER: FROM POWER SUPPLY(18 VDC, 3.0 A) RELAY OUTPUT: TWO LOW VOLTAGECONTACT CLOSURERELAYSDIGITAL INPUTS: THREE SCHMIDTTRIGGER TYPEIR OUTPUT: TO IRP2MIC INPUT: 3.5 mm TRS JACKBALANCED/UNBALANCED MONO LINE-LEVELCOMPUTER: RJ-11 SERIAL PORTTO LOAD FILESOR CONSOLELAN: 10/100 BASE-TETHERNET TO LANCOM: BI-DIRECTIONAL RS-232 WITHHARDWARE AND SOFTWAREHANDSHAKING AND MODEM CONTROLCOMPOSITE VIDEO OUTPUT: TO DISPLAY DEVICERGB OUTPUT: TO DISPLAY DEVICE NOTE: The power supply cable is equipped with a snap lock connector. Always disconnect the power cable by pulling back on the snap lock of the connector. Never pull the power cable by the cord. NOTE: Ensure that the unit is properly grounded. System Configuration Have a question or comment about Crestron software? Answers to frequently asked questions (FAQs) can be viewed in the Online Help section of the Crestron website. To post a question or view questions you have submitted to Crestron’s True Blue Support, log in at First-time users will need to establish a user account. Earliest Version Software Requirements for the PC NOTE: Crestron recommends that you use the latest software to take advantage of the most recently released features. The latest software is available from the Crestron website. Crestron has developed an assortment of Windows.-based software tools to develop a controlled system. The following are the minimum recommended software versions for the PC: Software TASK REQUIRED SOFTWARE VERSION Upload program and firmware. Crestron Toolbox 1.06.10 or later. Simplified configuration with wizards for iMedia systems (optional but recommended). iMedia Wizard; part of Crestron SystemBuilder™ version 3.0 or later (requires SIMPL Windows, VisionTools Pro-e, Crestron Database and Crestron Engraver) with Systembuilder Templates version 3.0 or later, Library update 485 or later, and Crestron Database version 18.8.2 or later. Refer to software release notes or Crestron website for other required Crestron software packages. Manage IM-RXV1-M or IM-RXV3-M systems within a facility (optional). RoomView® Server Edition. IR learning software (optional). DEAL for Windows version 3.02 or later. iMedia Wizard Configuration The iMedia Wizard is included with Crestron SystemBuilder and provides a quick method of configuring a custom iMedia system without prior programming knowledge. Once a system is configured, a test pattern can be sent to the projector to adjust the peaking level of each input. For additional details, download Crestron SystemBuilder from the Crestron website and examine the extensive help file. NOTE: All configuration is complete within the iMedia wizard only. This system cannot be configured in SystemBuilder or SIMPL™ Windows®. Uploading and Upgrading Crestron recommends using the latest programming software and that each device contains the latest firmware to take advantage of the most recently released features. However, before attempting to upload or upgrade it is necessary to establish communication. Once communication has been established, files (for example, programs or firmware) can be transferred to the device). Finally, program checks can be performed (such as creating an IP table) to ensure proper functioning. Establishing Communication Use Crestron Toolbox for communicating with the IM-RXV1-M and IM-RXV3-M; refer to the Crestron Toolbox help file for details. There are two methods of communication. Direct Serial Communication NOTE: Required for initial setup of Ethernet parameters. Direct Serial Communication IM-RXV1-MORIM-RXV3-MPC RUNNINGCRESTRON TOOLBOXSERIAL VIA CRESTRONCABLE STCP-502PCOR EQUIVALENT • The COMPUTER port on the IM-RXV1-M and IM-RXV3-M connects to the serial port on the PC via a serial cable (Crestron STCP-502PC or equivalent). • Use the Address Book in Crestron Toolbox to create an entry using the expected serial communication protocol (RS-232, auto-detect baud rate, no parity, 8 data bits, 1 stop bit, XON/XOFF disabled, RTS/CTS enabled). • Display the IM-RXV1-M or IM-RXV3-M’s “System Info” window (click the icon); communications are confirmed when the device information is displayed. TCP/IP Communication Ethernet Communication IM-RXV1-MORIM-RXV3-MPC RUNNINGCRESTRON TOOLBOXETHERNET • Establish serial communication between IM-RXV1-M or IM-RXV3-M and PC. • Enter the IP address, IP mask and default router of the IM-RXV1-M or IM-RXV3-M via the Crestron Toolbox (Functions | Ethernet Addressing); otherwise enable DHCP. • Confirm Ethernet connections between IM-RXV1-M or IM-RXV3-M and PC. If connecting through a hub or router, use CAT5 straight through cables with 8-pin RJ-45 connectors. Alternatively, use a CAT5 crossover cable to connect the two LAN ports directly without using a hub or router. • Use the Address Book in the Crestron Toolbox to create an entry for the IM-RXV1-M or IM-RXV3-M...

Ce manuel est également adapté pour les modèles :
Récepteur et amplificateur - IM-RXV1-M (1.21 mb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories