|
Facilité d'utilisation
b. For compatibility with older (unmodified) receivers, ensure that pin 2 is jumpered to pin 3 on both jumper locations. 5. Replace the cover, and reinstall the screws connector hex nut(s). 2-6 TP Receivers Mounting the receiver Rack mounting (TP R BNC A, TP R BNC AV, TP R 15HD A) TP R BNC A, TP R BNC AV, or TP R 15HD AV — For optional rack mounting, mount the receiver on a 19" 1U Universal Rack Shelf (Extron part #60-190-01) (figure 2-3). The TP R BNC A and TP R BNC AV mount on the left or right side of the rack. The TP R 15HD A mounts in one of eight locations on the rack. TP R 15 A RGB AK G LEVEL TP R 15HD A RGB PEAKING LEVEL TP R 15HD A RGB PEAKING LEVEL TP R BNC AV VIDEO MANUAL AUTO LEVEL PEAKING RGB MANUAL AUTO LEVEL PEAKING (2) 4-40 x 3/16" Screws Use 2 Mounting Holes on Opposite Corners Figure 2-3 — Rack mounting the TP R 15HD A and TP R BNC AV TP Receivers 2-7 Installation and Operation, cont’d TP R 15HD A only — For optional rack mounting, mount the receiver on a VersaTools 19" 1U Rack Shelf (Extron part # 60-190-20) (figure 2-4). The TP R 15HD A mounts in one of four locations on the rack. (2) 4-40 x 3/16" screws Use 2 Mounting Holes on Opposite Corners VersaTools Rack Shelf 1/4 Rack Width False Front Face Plate TP R 15HD A RGB PEAKING LEVEL TP R 15HD A RGB PEAKING LEVEL TP R 15HD A RGB PEAKING LEVEL Figure 2-4 — VersaTools rack mounting the TP R 15HD A 1. If feet were previously installed on the bottom of the receiver, remove them. 2. Mount the receiver on the rack shelf, using two 4-40 x 3/16 screws in opposite (diagonal) corners to secure the receiver to the shelf. 3. Install blank panel(s) (included in the 1U universal and VersaTools rack kits, optional for the 1U basic rack kit) or other unit(s) to the rack shelf. Only the TP R 15HD A and products in the Extron VersaTools line can be mounted on a VersaTools shelf. Any 1U rack-mountable Extron product can be mounted on the standard shelf. 2-8 TP Receivers Furniture mounting All of the receiver models can be mounted under furniture such as a table or podium surface using the appropriate optional mounting bracket, Extron’s Mini Under-Desk Mounting Kit (part #70-212-01) ( TP R 15 HD A) or Under-Desk Mounting Kit (part #70-077-01) ( all other models). All models except the TP R 15HD A can be mounted through a table or podium using Extron’s Through-Desk Mounting Kit ( part #70-077-02). Furniture mount the receiver as follows: 1. Attach the mounting brackets to the receiver with the machine screws provided (figure 2-5). Extron TP R BNC A Extron TP R BNC A Extron TP R 15HDA RGBINPUT RGBOUTPUT R G B H/HV V A AUDIO L R B SOG CSYNC POWER 15V.5ADC R Through-desk Mounted Under-desk Mounted TP R 15HD A RGB PEAKING LEVEL RGB INPUT RGB OUTPUT R G B V A AUDIO L R B SOGC SYNC POWER 15V .5A DC L R Under-desk Mounted Figure 2-5 — Under-desk or through-desk 2. For through-surface mounting (all except , cut the proper sized hole in the mounting surface. 3. Hold the receiver with the attached brackets underside of the table or other Mark the location of the screw holes of the bracket on the surface. 4. Drill 3/32” (2 mm) diameter deep in the mounting locations. TP Receivers 2-9 TP Receivers • Installation and Operation TP Receivers • Installation and Operation Installation and Operation, cont’d 5. For through-surface mounting (all except TP R 15HD A), insert four #8 wood screws through the bracket and into the four pilot holes. Tighten all four screws to secure the receiver in place. 6. For under-surface mounting, insert #8 wood screws into the four pilot holes. Tighten each screw into the mounting surface until just less than 1/4” of the screw protrudes. 7. For under-surface mounting, align the mounting screws with the slots in the brackets and place the receiver against the surface, with the screws through the bracket slots. 8. For under-surface mounting, slide the receiver slightly forward or back, then tighten all four screws to secure the switcher in place. Projector mounting All of the receiver models can be mounted on a projector bracket using the appropriate optional mounting bracket, Extron’s Mini Projector Mounting Kit (part #70-217-01) (TP R 15 HD A) or Projector Mounting Kit (part #70-077-04) (all other models). Secure the mounting bracket to the receiver using two machine screws in the side of the receiver (TP R 15HD A) or the three #8 machine screws provided (all other models). Secure the receiver to a projector mount or other surface by inserting the mounting bolt through the bracket’s slotted hole (figure 2-6). A A-V OUTPUT OUTPUT POWER 15V.5ADC L R BAVINPUTVIDEO TP R AV TP R 15HD A Mounting Bolt CSYNC SOG CVIDEO N/C L R AUDIO OUTPUT AVINPUT RGBPOWER 15V .34AMAX Mounting Bolt Projector Mounting Bracket Projector Mounting Bracket Figure 2-6 — Projector bracket mounting a receiver 2-10 Rear panel features and cabling TP R BNC A TP R BNC AV TP R AV RGB INPUT A-V INPUT 50/60 Hz 100-240V 0.3A RGB OUTPUT R VIDEO G B H/HV V A AUDIO AUDIO R L B SOG C SYNC ...
Ce manuel est également adapté pour les modèles :Récepteur et amplificateur - TP R AV (533.74 kb)