Log:
Évaluations - 0, GPA: 0 ( )

Instructions Yamaha, Modèle PC2001N

Fabricant : Yamaha
Taille : 1.38 mb
Nom Fichier :
Langue d'enseignement: itende
Aller à la télécharger



Facilité d'utilisation


Scene Recall Specifies whether scene recall from the ACD1’s panel is enabled (Enable) or disabled (Disable). EMG Scene Setup Specifies the scene number that will be recalled when the EMG (Emergency) signal is received from an external controller. Last Mem. Resume Specifies whether the ACD1 will start up with the settings that were in effect when the power was last turned off (ON) or whether it will start up by recalling the amp’s scene number that was in effect when the power was last turned off (OFF). Clock Setup Sets the date and time of the ACD1’s internal clock. GPI Calibration Calibrates the [GPI IN] connector input voltage. 6. Network Setup IP Address Mode Selects whether the ACD1’s IP address will be set automatically from Amp Editor (DHCP) or set manually (Manual). IP Address Specifies the ACD1’s IP address. MAC Address Displays the ACD1’s MAC address. IP Ctrl Port # Specifies the port number used when controlling the ACD1 via Ethernet from an external controller such as AMX/Crestron. 14 ACD1 Owner’s Manual Troubleshooting Symptom Possible causes Response All scene data saved in the ACD1 has disappeared. The power was turned off while the ACD1’s data was being saved. Synchronize with Amp Editor once again to transmit the settings from Amp Editor. The backup battery has run down. Check [5.Utility] > [Battery] for the state of the backup battery. If the state shows any message other than “OK,” ask qualified Yamaha service personnel to replace the backup battery. An alert message is displayed. An incorrect or abnormal connection with the amplifier or other alert event related to the connections has occurred. For details on the meaning of each alert message and the appropriate measures to take, refer to the Amp Editor Owner’s Manual. Panel operations are not accepted. The unit is locked. For details, refer to “5.Utility” in the ACD1 reference manual. A scene can be saved but not recalled. “Scene Recall” is set to “Disable.” Access [5.Utility], then [SceneRecall] and set it to “Enable.” The LCD is not backlit. “LCD Backlight” is set to “Auto OFF.” To set the unit so that the LCD remains backlit at all times, access [5.Utility], then [LCD Backlight] and set it to “ON.” Initializing the internal memory You can initialize the ACD1’s internal memory. NOTE • The log data is preserved even if you execute initialization. CAUTION • When you initialize the internal memory, the content that had been saved in memory (scenes for each amp, and ACD1 settings) will be lost. Use caution when performing the following steps. 1. Power-off the ACD1. 2. While holding down the [BACK] button, turn the power on. 3. Press the [^INC/YES] button to initialize the internal memory. When initialization is completed, the ACD1 will automatically restart. • During initialization, the message “Do not turn off!” will be shown in the display. Never power-off the amplifier while this message is displayed. CAUTION ACD1 Owner’s Manual 15 EN EN Information for Users on Collection an...

Ce manuel est également adapté pour les modèles :
Récepteur et amplificateur - PC3301N (1.38 mb)
Récepteur et amplificateur - PC4801N (1.38 mb)
Récepteur et amplificateur - PC6501N (1.38 mb)
Récepteur et amplificateur - PC9501N (1.38 mb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories