|
Facilité d'utilisation
Some of these features are listed below. Model 69X-06-XX Specifications • 78 ft. – 108 ft. Radius • Pop-Up Nozzle and Cap -7.8 in. •11.2 in. NPT Female Thread Inlet • Recommended Operating Pressure: 60 – 100 PSI • Maximum Pressure: 150 PSI • Electric Models: – Solenoid - 24 VAC – Inrush Current - .40 Amps – Holding Current - .235 Amps • Dimensions: – Cap Diameter - 71.2 in. – Flange Diameter - 10 in. – Height - 16 in. Model 69X-01-XX Model 69X-02-XX Features • Positive Spring Retraction -Pulls nozzle and cap down out of the way of people and turf maintenance equipment. • Three Nozzle Sizes - Multiple nozzle sizes provide 45.1 to 82.2 GPM flow and produce watering radii from 78 to 108 feet. • Long Life Gear Drive - Gear drive mechanism is vacuum-packed with lubricant and isolated from water stream for long, trouble-free life. • Valve-In-Head Models -Permits head-by-head control to customize turf watering for various topography and soil conditions. Multi-cycle for wind or runoff problems, frost control and dew removal without low-head drainage. Available for hydraulic normally open or 24 Volt electric systems. • Sprinkler Operating Mode - Electric valve-in-head models have three modes of operation; AUTO, ON and OFF. Mode is set using a selector tool inserted through the sprinkler body flange. • Built-in Check Valve - Check-o-matic sprinklers utilize a check valve in the sprinkler base to prevent seepage from low area heads after valve closure. Check valve will hold up to 35 feet of elevation differential. • Two-Speed / 60°-120° Models -Provides for more even precipitation. Runs at half speed in non-overlapping areas. • Two-Speed / 180° Models -Provides for more even precipitation where only a selected area is covered by an overlap, such as is found on greens. Runs at half speed in non-overlapping areas. • Serviceability -All internal parts of the sprinkler are accessible through the top of the sprinkler body. Conversion Information MODEL NUMBER CODE Arc 1 = Quarter Circle 2 = Half Circle Regular Speed 4 = Full Circle 6 = Two Speed 60°-180° 8 = Two Speed 180° 69X-XX-XX Cover Operation 0 = Standard 1 = Valve-in-head Hydraulic N.O. 2 = Checkomatic 6 = Valve in head electronic A = 150° B = 165° C = 195° D = 210° Nozzle Set -90 = 3/8 in. -91 = 7/16 in. -92 = 1/2 in. • All gallons per minute shown are U.S. • To convert to Imperial gallons per minute, multiply by .833. • To convert to litres per minute, multiply by 3.78. • To convert pounds per square inch (PSI) to atmospheres, divide by 14.7. • To convert pounds per square inch (PSI) to kilograms per square centimeter (kg/cm2) divide by 14.22. • To convert feet to meters, divide by 3.28. • To convert inches to millimeters, multiply by 25.4. Performance Chart Base Pressure Nozzle Set -90 Size 3/8 in. Nozzle Set -91 Size 7/16 in. Nozzle Set -92 Size 1/2 in. PSI Rad. GPM Rad. GPM Rad. GPM 40 50 60 78 ft. 45.1 87 ft. 53.7 70 82 ft. 48.6 91 ft. 57.2 96 ft. 67.5 80 87 ft. 51.0 96 ft. 61.2 100 ft. 74.0 90 89 ft. 54.1 98 ft. 67.3 105 ft. 78.0 100 90 ft. 57.1 100 ft. 73.4 108 ft. 82.2 Spacing of Sprinklers Square Spacing No Wind 55% of diameter 4 m.p.h. 50% of diameter 8 m.p.h. 45% of diameter Triangular Spacing No Wind 60% of diameter 4 m.p.h. 55% of diameter 8 m.p.h. 50% of diameter Single Row Spacing No Wind 50% of diameter 4 m.p.h. 50% of diameter 8 m.p.h. 45% of diameter Installation Procedure To assure maximum performance from your 690 Series Rotary Sprinklers, read these instructions completely prior to installing or servicing the sprinkler. Construct Swing Joints 1. Construct triple swing joints for each sprinkler as shown in Figure 1. Use PVC or ABS pipe nipple for sprinkler connection. Note: On sites where the possibility of heavy equipment rolling over a sprinkler exists, the swing joint will flex preventing damage to the lateral or main lines. On a new installation in raw ground where the sprinklers are to be initially installed above the finished grade and lowered when new turf is established, the swing joint allows sprinkler repositioning without changing risers. This is a common and practical procedure which eliminates the problem of dirt being accidentally introduced into the lateral lines when a riser is changed. 2. Flush lines thoroughly prior to installing sprinkler. 3. Apply Teflon tape on riser threads. Install sprinkler to riser and tighten. CAUTION Figure 1 Triple Swing Joints Use only Teflon™ tape on riser threads. Use of pipe dope or other types of sealing compounds can cause deterioration of sprinkler body threads. 2 Connecting Electric Control Wires Table 1 - Wire Sizing Chart Table 1 - Wire Sizing Chart 1. Route control wires to sprinkler location(s). Provide Maximum Allowable Length in Feet From Controller to VIH Sprinklers. enough extra wire at sprinkler to allow for movement of sprinkler without straining wire connections. One common wire and one station wire are required for each sprinkler. See Wire Sizing Chart, Table 1 for proper applicatio...
Ce manuel est également adapté pour les modèles :Outils de jardin - 69X-02-XX (231.85 kb)
Outils de jardin - 69X-06-XX (231.85 kb)