Fabricant : Bradley Smoker
Taille : 2.24 mb
Nom Fichier :
|
Facilité d'utilisation
Possible solenoid contamination could occur and will void any warranty. Mounting of Lavatory and Gooseneck Faucet Prerequisites • Supply valve is installed • Water supply lines are fl ushed properly • For AC faucets, power outlet is installed It is not necessary to unscrew the connection between braided hose and housing to install the product. Do not remove protective covering from sensor until starting up faucet operation. Do not tighten locknut before step 4 is completed. 1 Mount cover plate if required. Plumber.s putty is recommended to seal the cover plate to the sink. Security pin must be located on the left side. 2 Mount gasket and put faucet into sink. 3 Mount bracket from underneath. Place hoses through large opening and mounting rod through small opening. Make sure fl ange sits securely against surface. 4 Place nut onto mounting rod and tighten with wrench. 5 If faucet was installed with cover plate, secure with basin washer, fl at washer and locknut. 6 Install aerator and tighten with aerator key (supplied). 7 For Gooseneck faucets, tighten spout with wrench. 8 Connect braided hose with fi lter to supply valve Cold water > white label Hot water > no label For AC faucets, please refer to the plugin or hardwired transformer installation instructions. 9 Connect to power supply. Result: The faucet is now mounted. Installation Aerada 1000/1100 Series Bradley Corporation • 215-1628 Rev. A; EN 08-201 5/21/08 5 Start-up Operation Prerequisites • Faucet is mounted • Water supply is on • Water supply lines are fl ushed properly • F or AC faucets, power outlet is installed. 1 Fully open supply valves. 2 Remove all items from sink. 3 Remove protective covering from sensor. 4 Wait for 15 seconds for the faucet to calibrate to its environment. Result: The faucet is now activated. 15 sec. Test Function 1 Hold hand in front of sensor. > Water fl ow starts WARNING Hot water may burn your skin. Hold hand carefully under water and remove quickly 2 For faucets with external mixer, turn mixer handle from cold to warm. > Water temperature increases 3 Remove hand. > Water fl ow stops Result: The function is now tested. Aerada 1000/1100 Series Installation 6 5/21/08 Bradley Corporation • 215-1628 Rev. A; EN 08-201 Enabling “Manual Setting Mode” A battery model is shown in the following example. These instructions apply to all models. After 30 minutes, the “Manual Setting” mode will be disabled automatically and all settings will be saved. Prerequisites • Water supply valve is open • Battery is full (LED does not blink) for DC faucets • A C power is on for AC faucets 1 Remove shut-off screw. 2 Remove mixer handle (only for faucets with external mixer). 3 Remove housing vertically. 4 Remove battery from battery holder. 5 The following procedure (a, b, c) must be done three (3) times in a row. a - Re-insert battery b - LED lights up c - Remove battery immediately after LED switches off 6 Insert battery. 7 Mount housing vertically. 8 Mount shut-off screw. a c b Installation Aerada 1000/1100 Series Bradley Corporation • 215-1628 Rev. A; EN 08-201 5/21/08 7 9 Mount mixer handle (only for faucets with external mixer) Result: The faucet is now mounted. A - Setting Cleaning Mode Setting the cleaning mode will make the faucet inactive for 90 seconds. 1 Enable “Manual Setting” Mode > See “Enabling Manual Setting Mode” section 2 Fully cover sensor with hand, until water fl ow stops. (This takes 5 seconds.) 3 Remove hand. Result: The Cleaning Mode is now active. For the next 90 seconds, the faucet will be inactive. B - Setting Normal Mode Setting the normal mode will allow the faucet to activate only when it senses a hand presence. 1 Enable “Manual Setting” Mode > See “Enabling Manual Setting Mode” section 2 Fully cover sensor with hand. Water fl ow stops after 5 seconds - Continue to hold on for one (1) additional water pulse. 3 Remove hand. Result: Normal Mode is now activated. C - Setting Metering Mode (10 seconds) Setting the metering mode will allow the faucet to activate for a full 10 seconds after if senses a hand presence. 1 Enable “Manual Setting” Mode > See “Enabling Manual Setting Mode” section 2 Fully cover sensor with hand. Water fl ow stops after 5 seconds - Continue to hold on for another two (2) additional water pulses. 3 Remove hand. Result: Metering Mode is now activated for 10 seconds. Aerada 1000/1100 Series Installation 8 5/21/08 Bradley Corporation • 215-1628 Rev. A; EN 08-201 D - Setting Scrub Mode (60 seconds) Setting scrub mode for 60 seconds will allow the faucet to activate for 60 seconds from the last hand presence. 1 Enable “Manual Setting” Mode > see “Enabling Manual Setting Mode” section 2 Fully cover sensor with hand. Water fl ow stops after 5 seconds - Continue to hold on for another three (3) additional water pulses. 3 Remove hand. Result: Scrub Mode is now activated for 60 seconds. E - Setting Scrub Mode (180 seconds) Setting scrub mode for 180 seconds will allow the faucet to activate for 180 secon...
Ce manuel est également adapté pour les modèles :Plomberie - AERADA 1000 Series S53-327 DC (2.24 mb)
Plomberie - AERADA 1000 Series S53-328 (2.24 mb)
Plomberie - AERADA 1000 Series S53-329 (2.24 mb)