Instructions Adder Technology, Modèle 3192 H4TU-C

Fabricant : Adder Technology
Taille : 129.87 kb
Nom Fichier : 5246595f-ca68-b294-058f-80f592dabd10.pdf
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


3 dB. LED STATUS DSX EQ SPLITTING JACKS DSX MONITOR JACKS COMPLIANCE POWERING MODE utCode Input Output Power Code (PC) F C Telecommunication Code (TC) – X Installation Code (IC) A – 1. DSX-1 Line Build Out 0-133 Feet 0-133 Feet Provisioning Options Option Settings Default Settings Red Loop 1/ Loop 2 synchronization not achieved, in sync with errors, or SNR margin < 3 dB. 133-266 Feet 266-399 Feet DSX Green DSX-1 signal present and no errors currently detected. 399-533 Feet Red In framed mode, denotes loss of framing or loss of sync at the 533-655 Feet DSX-1 input. In unframed mode, denotes loss of signal DSX-1 input. 2. DSX-1/DS1 Line Code AMI, B8ZS B8ZS 3. DSX-1/DS1 Framing SF, ESF, Unframed, Auto ESF ALM Off No T1 alarms are active. 4. Forced Frame Conversion Enabled, Disabled Disabled Red Loss of DSX-1 signal from the network. 5. Smartjack Loopback Enabled, Disabled Enabled Yellow Loss of DS1 signal from the CPE. 6. Loopback Timeout None, 120 Minutes 120 Minutes ESF/SF Off Unit has detected Unframed data. 7. Latching Loopback Mode T1 (Disabled), FT1 (Enabled) T1 (Disabled) Yellow Unit has detected ESF framing data. 8. DS1 TX Level 0 dB, –7.5 dB, –15 dB –7.5 dB Green Unit has detected SF framing data. 9. Span Power Enabled, Disabled Enabled B8ZS/AMI Yellow Unit has detected B8ZS line coding data. 10. Customer Loss Indicator AIS, AIS/CI, Loopback AIS/CI Green Unit has detected AMI line coding data. 11. PRM Setting None, SPRM, NPRM, Auto Auto LBK Off No local loopbacks active. 12. Loop Atten Alarm Threshold 0 (Disabled) 34 dB Yellow Local loopback active. 1-99 dB 13. SNR Margin Alarm Threshold 0 (Disabled) 4 dB 1-15 dB 14. Remote Provisioning Enabled, Disabled Enabled TX DSX-1 transmit toward the local loop (intrusive) RX DSX-1 receive from the local loop (intrusive) #61222404L1-22D# DEFAULT PROVISIONING VALUES H4TU-C EDGE CONNECTOR WIRING R Tx DSX (In from DSX) TX DSX-1 transmit toward the local loop (nonintrusive) 1 R1 Rx DSX (Out to DSX) 2 RX DSX-1 receive from the local loop (nonintrusive) 3 4 GND 5 R1 HDSL4 Loop 2 WARNING: Up to –200 VDC might be present on telecommunications wiring. Ensure chassis 6 ground is properly connected. The DSX-1 interface is intended for connection to 7 —48V intra-building wiring only. 8 R HDSL4 Loop 1 This product is intended for installation in restricted access locations only and in equipment 9 with a Type “B” or “E” enclosure. 10 Fuse Alarm (to Alarm Module) T Tx DSX (In from DSX) A T1 Rx DSX (Out to DSX) B C D E T1 HDSL4 Loop 2 This product provides span powering voltage (negative only with respect to ground, –190 VDC F RCV LOS (to Alarm Module) nominal, GFI protection < 5 mA) and meets all requirements of Bellcore GR-1089-CORE (Class A2), H Frame Ground and ANSI T1.418-2002. This product is NRTL Listed to the applicable UL standards. J T HDSL4 Loop 1 K L The H4TU-C provides –190 VDC span powering voltage and will provide powering to the H4Rs and the H4TU-R. The –190 VDC span powering voltage is provided on Loop 2. C A U T I O N C A U T I O NC A U T I O N ! SUBJECT TO ELECTROSTATIC DAMAGE OR DECREASE IN RELIABILITY. HANDLING PRECAUTIONS REQUIRED. For a complete Installation and Maintenance Practice (P/N 61222404L1-5): 877-457-5007, Faxback Document 885. Please have your fax number ready. HDSL4 TROUBLESHOOTING GUIDE PRICING AND AVAILABILITY 800.827.0807 TECHNICAL SUPPORT 800.726.8663 RETURN FOR REPAIR 256.963.8722 61222404L1-22D PRICING AND AVAILABILITY 800.827.0807 TECHNICAL SUPPORT 800.726.8663 RETURN FOR REPAIR 256.963.8722 61222404L1-22D ADTRAN HDSL4 equipment is designed with troubleshooting-at-a-glance features. The following information provides suggestions for troubleshooting as a result of LED indications which are indicative of loop trouble. NOTE: Pressing “ESC” while on any screen will go back to the previous screen. INDICATIONS AND POSSIBLE CAUSES DSL LED Red Connect a terminal or PC to the RS-232 (DB-9) craft interface on the front panel. The terminal must be VT100 or compatible and set for 1.2 to 19.2 kbps, 8 data bits, no parity, 1 stop bit, no flow control. Select “3” from the ADTRAN HDSL4 Main Menu screen and “1” from the Span Status Screen. Verify the following conditions on the HDSL4 and T1 Detailed Status Screen: Margin . 3 dB ¦ Attenuation . 35 dB (1st segment) Attenuation . 31 dB (2nd segment) ¦ No ES, SES, or UAS (Performance History Screen, Main Menu Selection 5) If the above conditions do exist, the circuit should provide quality service; however, if any of the above conditions do not exist, a cable problem or excessive loss situation is probable, and more detailed cable testing should be done to verify all HDSL4 loop specifications are met. These conditions may also reflect intermittent cable faults or excessive noise impairments. If intermittent faults or noise impairments are suspected, review the Performance History Screen. NOTE: The insertion loss reading shown on the Detailed Status Screen is an...


Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories