Log:
Évaluations - 2, GPA: 4 ( )

Instructions Agilent Technologies, Modèle N1022A

Fabricant : Agilent Technologies
Taille : 570.43 kb
Nom Fichier : N1022-90001.pdf
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


Manual Part Number N1022-90001 Edition First edition, April 2003 Printed in USA Agilent Technologies, Inc. Lightwave Division 1400 Fountaingrove Parkway Santa Rosa, CA 95403, USA Warranty The material contained in this document is provided “as is,” and is subject to being changed, without notice, in future editions. Further, to the maximum extent permitted by applicable law, Agilent disclaims all warranties, either express or implied, with regard to this manual and any information contained herein, including but not limited to the implied warranties of merchantability and fitness for a particular purpose. Agilent shall not be liable for errors or for incidental or consequential damages in connection with the furnishing, use, or performance of this document or of any information contained herein. Should Agilent and the user have a separate written agreement with warranty terms covering the material in this document that conflict with these terms, the warranty terms in the separate agreement shall control. Technology Licenses The hardware and/or software described in this document are furnished under a license and may be used or copied only in accordance with the terms of such license. Restricted Rights Legend If software is for use in the performance of a U.S. Government prime contract or subcontract, Software is delivered and licensed as “Commercial computer software” as defined in DFAR 252.227-7014 (June 1995), or as a “commercial item” as defined in FAR 2.101(a) or as “Restricted computer software” as defined in FAR 52.227-19 (June 1987) or any equivalent agency regulation or contract clause. Use, duplication or disclosure of Software is subject to Agilent Technologies’ standard commercial license terms, and non-DOD Departments and Agencies of the U.S. Government will receive no greater than Restricted Rights as defined in FAR 52.227-19(c)(1-2) (June 1987). U.S. Government users will receive no greater than Limited Rights as defined in FAR 52.227-14 (June 1987) or DFAR 252.2277015 (b)(2) (November 1995), as applicable in any technical data. Safety Notices CAUTION Caution denotes a hazard. It calls attention to a procedure which, if not correctly performed or adhered to, could result in damage to or destruction of the product. Do not proceed beyond a caution sign until the indicated conditions are fully understood and met. WARNING Warning denotes a hazard. It calls attention to a procedure which, if not correctly performed or adhered to, could result in injury or loss of life. Do not proceed beyond a warning sign until the indicated conditions are fully understood and met. ii Contents Contents General Safety Considerations 2 Instrument Markings 3 Using the Probe Adapter 4 Inspecting the N1022A 4 Connecting the N1022A 5 Static-Safe Workstation 8 Reducing ESD Damage 9 Specifications and Regulatory Information 10 Specifications 10 Regulatory Information 13 Declaration of Conformity 14 Service 15 Checking Probe Power Outputs 15 Returning the N1022A 16 Agilent Technologies Service Offices 17 Contents 1 Contents Contents N1022A Active Probe Adapter N1022A Active Probe Adapter The N1022A Active Probe Adapter provides the interface to connect an Agilent Infiniimax Active Probe to an Agilent 86100-series Infiniium DCA. To use the N1022A requires that firmware revision A.03.05 or later be installed on the Infiniium DCA. The Infiniimax Active Probes include the following: 1131A, 1132A, and 1134A. Other supported active probes include the 1152A, 1156A, 1157A, and 1158A. CAUTION When using the N1022A, always work at a static-safe work station and wear a wrist-strap or heel-strap. Refer to “Static-Safe Workstation” on page 8. CAUTION The probe adapter connections can be damaged if it is dropped from excessive heights onto a hard surface. General Safety Considerations General Safety Considerations WA R N I N G This product has been designed and tested in accordance with the standards listed in the Manufacturer’s Declaration of Conformity, and has been supplied in a safe condition. The product documentation contains information and warnings which must be followed by the user to ensure safe operation and to maintain the product in a safe condition. Before using this product, review the safety information for cautions and warnings. Use this product according to the enclosure protection provided. This product does not protect against the ingress of water. This product protects against finger access to hazardous parts within the enclosure. If this product is not used as specified, the protection provided by the equipment could be impaired. This product must be used in a normal condition (in which all means for protection are intact) only. WA R N I N G No operator serviceable parts inside. Refer servicing to qualified personnel. To prevent electrical shock, do not remove covers. WA R N I N G To prevent electrical shock, disconnect the Agilent N1022A from probe power before cleaning. Use a dry cloth to clean the external case p...


Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories