Log:
Évaluations - 5, GPA: 3.8 ( )

Instructions Allied Telesis, Modèle AR44x

Fabricant : Allied Telesis
Taille : 107.17 kb
Nom Fichier :
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


This issue has been resolved. The mask parameter is now valid for this command. Y Y Y Y Y Y Y Y Y Y CR00013007 IPsec 3 With tunnel-mode IPsec, the router or switch decremented the time to live ( TTL) of IP packets twice when it forwarded the packets through the tunnel. This issue has been resolved. Y Y Y Y Y - - - - - CR00013048 Firewall 3 When IP NAT or firewall NAT was used, the router or switch sometimes generated ICMP messages that specified the wrong source IP address. This meant that the response to traceroute could be incorrect. This issue has been resolved. Y Y Y Y Y - - - - - Version 281- 01 C613- 10482- 00 REV A Features in 281- 01 CR Module Level Description AR400AR7x5AR750S / AR770SRapier iAT-8800AT-8600AT-8700XLAT-8948 / x900-48AT-9900AT-9800 CR00013049 IPv6 3 The router or switch sometimes rebooted when it processed a large number of multicast routes that were created as the result of receiving a large amount of data from more than 500 multicast groups. This issue has been resolved. Y Y Y Y Y - - Y Y Y CR00013085 OSPF 3 A user can configure a range on an OSPF ABR, so that the ABR aggregates the network advertisements from one area into another area in the form of summary LSAs. However, networks advertised into a transit area should not be aggregated into summary LSAs. Previously, the router or switch advertised aggregated summary LSAs into transit areas when a range had been configured. This issue has been resolved. When the router or switch is advertising into a transit area, it ignores any configured range. Y Y Y Y Y Y Y Y Y Y CR00013093 Switch 3 When traffic on a port was mirrored and that port had a learn limit set, packets from the CPU ( such as ARP replies and ICMP replies) were not always mirrored. This issue has been resolved. - - - Y Y Y Y - - - CR00013190 Core 3 If a AT- 8624PoE switch had a sticky fan, the fan constantly toggled between running at full speed and slowing down. This meant that the fan continuously generated alarms. This issue has been resolved. If the fan reports an error more than 3 times in an hour, it now remains at its maximum speed setting. - - - - - Y - - - - CR00013202 Core 3 On the AT- 8624PoE switch, a fan fault alarm was not generated when the fan speed dropped to 70% of the expected speed. This issue has been resolved. When the speed drops to 70% or less, a alarm is now generated. - - - - - Y - - - - Version 281- 01 C613- 10482- 00 REV A Features in 281- 01 CR Module Level Description AR400AR7x5AR750S / AR770SRapier iAT-8800AT-8600AT-8700XLAT-8948 / x900-48AT-9900AT-9800 CR00013243 Core 3 The system LED did not indicate when an internal power supply fault occurred. This issue has been resolved. The system LED now flashes 3 times to indicate a fault. Also, output of the show system command now reports voltages more accurately. - - Y - - - - - - - CR00013279 OSPF 3 When a user changed the OSPF priority of an interface, the router or switch did not immediately perform the process to elect a Designated Router and Backup Designated Router (BDR) . This issue has been resolved. Y Y Y Y Y Y Y Y Y Y CR00013353 Switch 3 Certain BIST and AUTOBURNIN tests reported errors, especially if an IPv6 accelerator was installed. Also, if a user entered the commands disable or enable switch learning and an IPv6 accelerator was installed, the switch displayed an error message that said: “SWI ERROR: (1) swmxMacLearningSet [ 1] - Unable to set learning” These issues have been resolved. - - - - - - - Y Y - CR00013421 BGP 3 When a user created a BGP module trigger for the peerstate event, the router or switch did not allow specification of the script or state parameters. This issue has been resolved. All such generic parameters are now available with module- specific triggers. Y Y Y Y Y - - Y Y Y CR00013538 IP Gateway 3 Software Version 2.8.1 introduced a new msgtype parameter for the command add igmp filter, which enables users to filter on IGMP query, report or leave messages. This parameter was mistakenly made compulsory. Therefore, if an existing configuration script contained IGMP filters, and the router or switch restarted with that configuration, the filters did not work. This issue has been resolved. The msgtype parameter is now optional, with a default of report. Y Y Y Y Y Y Y Y Y Y Version 281- 01 C613- 10482- 00 REV A Features in 281- 01 Level 4 CR Module Level Description AR400AR7x5AR750S / AR770SRapier iAT-8800AT-8600AT-8700XLAT-8948 / x900-48AT-9900AT-9800 CR00010159 GUI 4 When the web- based GUI is used to add or remove ports from a port- based VLAN association on an AT- 9812T switch, the icons representing alternate ports faced opposite directions. This issue has been resolved. The port icons now all have the same orientation. - - - - - - - - - Y CR00011311 IPsec 4 In output of the commands show ipsec policy and show ipsec policy sabundle, the value for the number of bytes currently used by each SA bundle was sometimes truncated. This issue has been resolved, and both...

Ce manuel est également adapté pour les modèles :
Matériel de réseau - AR4155 (107.17 kb)
Matériel de réseau - AR700 (107.17 kb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories