ERROR CODES ER01: CPU Error This type of error indicates that the CPU is not working properly. ER02: I.C Communication Error This means that the communication between the MT105-110/(111) card and its serial device has failed. ER03: RS485 Communication Error This type of error is a communication error between the MT105-110/(111) card and the controller of the Multi-Tasker™ Enclosure. [CiS] This command saves card status such as ON/OFF, IN/OUT connection as default settings 3. [IO] This command will connect input x with output y, but the user needs to use the [ON] command to enable this output. Command Format: [IxOyCnUi] 9 MULTI-TASKER Ix = select input x (x is # from 1 to 16) Oy = connect to output y (y is # from 1 to 8) Cn = card ID number (n is # from 1 to 19) (1 to 8 for MT100-101 or 1 to 4 for MT100-106) Ui = unit ID, i is # from 0 to 9). (Refer to MT100100 user’s guide to set Unit ID). S = saves command to memory Example: To connect input 4 to output 2 (card 2 of unit 3), use the [I4O2C2U3] command. [ImO*…]. This command connect input m to all outputs. 4. [ON] This command enables one or more outputs of a single card or a group of cards [ONmCnUiS]: for a single card This command enables output “m” without affecting any other outputs. Default when plugged in = ALL OFF m = Output number (m = 1 to 8) n = Card ID number (n = 1 to 19) (1 to 8 for MT100-101 or 1 to 4 for MT100-106) i = Unit ID number (i = 0 to 9) S = saves command to memory Example: 1) [ON12C5U3]: Turns ON only output 1 and 2 of the MT105-110/(111) card located in slot #5 of the MT100-100 Enclosure with unit ID3. 2) [ON3C5U3]: Turns ON only output 3 of the MT105-110/(111) card located in slot #5 of the MT100-100 Enclosure with unit ID3. After the [ON12C5U3] and [ON3C5U3] commands have been executed, output 1, 2 and 3 will be ON. 3) [ONC5U3]: Turns ON all outputs of the card. [ONmGkUiS]: for a group of cards This command enables output "m" for each card in group "k" of unit "i". m = card output (m = # from 1-8) k = group number (k = # from 1-9) i = unit number (i = # from 0-9) S = saves command to memory Example: 1. [ON1G5U1]: Turns ON output 1 for each card in group5 of unit 1. 2. [ONG5U1]: Turns ON all outputs for each card in group5 of unit 1. [ON…..P]: sets path This command will set the path for the output, but it is not active until the switch command is executed ( [SW] ). Commands ending in "P" are not executed immediately. The path for outputs on multiple cards or the same card can be loaded. Command Format: [ONmCnUiP] m = Output number (m =1 to 8) n = card ID No. (n = a slot # from 1 to 19) (1 to 8 for MT100-101 or 1 to 4 for MT100-106) P = path Example: If 2 cards are at slot 6 and 7 of unit 3: To enable output 1 and 2 of card 6 and output 3 and 4 of card 7 simultaneously, use the following commands: [ON12C6U3P] [ON34C7U3P] [SW] If "F" is included use the [ONmCnUiPF] command or the [ONmCnUiFP] command. 10 MULTI-TASKER [ON…..F]: feedback After processing a command, an OK or ER will be returned as feedback if "F" is included at the end of a command string or if the unit ID is zero. Example: [ON1C2U3F]: if path is not set [ON1C2U3PF]: if path is set 5. [OFF] This command disables one or more outputs of a single card or a group of cards. [OFFmCnUiS]: for a single card This command disables output “m” without affecting any other outputs. m = output number (m = 1 to 8) n = card ID No. (n = slot # from 1 to 19) (1 to 8 for MT100-101 or 1 to 4 for MT100-106) I = Unit ID number (i = 0 to 9) S = saves command to memory [OFFCnUi]: Turns OFF all outputs of the card Example: 1) If card 5 of unit 3 has output 1, 2 and 3 ON: a) [OFF1C5U3]: Turns OFF output 1 while output 2 and 3 remain ON. b) [OFF23C5]: Turns OFF output 2 and 3. 2) If card 5 of unit 3 has output 1, 2, 3, 4, 5, 6, 7 and 8 ON: a) [OFFC5U3]: Turns OFF all outputs, which is equivalent to [OFF12345678C5U3]. [OFFmGkUiS]: for a group of cards This command disables output "m" for each card in group "k" of unit "i". Command Format: [OFFmCnUiP] m = card output (m = # from 1-8) k = group number (k = # from 1-9) (1 to 8 for MT100-101 or 1 to 4 for MT100-106) i = unit number (i = # from 0-9) S = saves command to memory Example: 1. [OFF1G5U1]: Turns OFF output 1 for each card in group5 of unit 1. 2. [OFFG5U1]: Turns OFF all outputs for each card in group5 of unit 1. [OFF…..P]: sets path This command will set the path for the output, but it is not active until the switch command is executed ([SW]). Commands ending in "P" are not executed immediately. The path for outputs on multiple cards or the same card can be loaded. Command Format: [OFFmCnUiP] m = output number (m =1 to 8) n = card ID No. (n = a slot # from 1 to 19) (1 to 8 for MT100-101 or 1 to 4 for MT100-106) P = path Example: If 2 cards are at slot 6 and 7 of unit 3: To enable output 1 and 2 of card 6 and output 3 and 4 of card 7 simultaneously, use the following commands: OFF12C6U3P] [OFF34C7U3P] [SW] If "F" is included use the [OFFmCnUi...

Ce manuel est également adapté pour les modèles :
Matériel de réseau - 400-0226-003 (881.85 kb)
Matériel de réseau - MT105-110 (881.85 kb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories