Par ce dispositif a également d'autres instructions :
Facilité d'utilisation
0xe0000000017716b0 DoCalllist+0x3a0
End of Stack Trace
This problem happens on HP Integrity rx2600, rx3600, rx6600, BL860c systems, and on rx7640
and rx8640 systems with AH303A adapters installed.
Corrective Action: Reboot the system to recover from the panic.
5 Recommendations
This section provides recommendations for highest performance and reliability.
•
Updating Physical Disk Firmware
Consider the following when you use sasmgr(1M) to update the firmware of physical disks
that are part of a RAID volume attached to an HP 8 Internal Port SAS Controller:
— If you are updating the firmware on two or more disks that are part of a RAID volume,
do not issue multiple commands to download simultaneously.
— If the disk firmware download to a disk that is part of a RAID volume fails or is
terminated, reset the controller using the sasmgr(1M) reset command:
sasmgr -f reset -D /dev/sasdX
(Replace X with the instance of the SAS controller.)
•
Swapping Spare Disks
Consider the following when you swap physical disks in a RAID volume controlled by an
HP 8 Internal Port SAS Controller:
— Before swapping a spare disk, delete it using sasmgr(1M):
sasmgr delete -D /dev/sasdX -q raid -q spare
(Replace X with the instance of the SAS controller.)
After the new disk is installed, use sasmgr(1M) to configure the new disk as spare:
sasmgr add -D /dev/sasdX -q raid -q spare -q enc_bay=
(Replace X with the instance of the SAS controller and
of the disk to be configured as spare.)
— By default, RAID volumes are created with Auto-Configure enabled. If you swap a
physical disk that is part of a RAID volume, a resync begins and data on the new disk
is lost. Do not insert a replacement disk unless you are sure that existing data is backed
up.
6 Compatibility and Installation Requirements
This section describes the compatibility information and installation requirements for this release.
For specific installation instructions, see the HP 8 Internal Port SAS Controller and HP Multi-Port
Internal SAS Controller Support Guide or the AH303A PCIe SC44Ge SAS Host Bus Adapter for Integrity
Servers Support Guide, at:
http://docs.hp.com/en/netcom.html
6.1 Required Software
The SerialSCSI-00 bundle depends on SAS-COMMON, which is delivered as a part of the
CommonIO bundle. Before installing SerialSCSI-00, be sure that SAS-COMMON is installed.
This version of SerialSCSI-00 requires version C.7.4.157 or later of Ignite-UX.
You can download these products from the Software Depot website:
http://www.hp.com/go/softwaredepot
Search for CommonIO and Ignite-UX.
6
... Ce manuel est également adapté pour les modèles :
Matériel de réseau - HP-UX 11i v3 I/O Cards (331.55 kb)