Facilité d'utilisation
Therefore, no further lubrication is required. CLEANING THE AIR FILTER SCREEN See Figures 10 - 11. For proper performance and long life, keep the air filter screen clean. . Remove the hex nut, wavy washer, flat washer, and choke dial cover. . Brush the air filter screen lightly to clean. . Reinstall the choke dial cover, flat washer, wavy washer, and hex nut. Fig. 10 Fig. 11 HEX NUT FILTER screen FILTER SCREEN BRUSH wavy washer flat washer choke dial cover SPARK PLUG This engine uses a Champion RCJ6Y or equivalent spark plug with .025 in. electrode gap. Use an exact replacement and replace annually, or more frequently if necessary. WARNING: Be careful not to cross-thread the spark plug. Crossthreading will seriously damage the product. MAINTENANCE FUEL CAP WARNING: A leaking fuel cap is a fire hazard and must be replaced immediately. Failure to do so could result in a fire that could cause serious personal injury. MAINTENANCE FUEL CAP WARNING: A leaking fuel cap is a fire hazard and must be replaced immediately. Failure to do so could result in a fire that could cause serious personal injury. CLEANING THE EXHAUST PORT ANd MUFFLER Depending on the type of fuel used, the type and amount of lubricant used, and/or your operating conditions, the exhaust port and muffler may become blocked with carbon deposits. If you notice a power loss with your gas powered tool, you may need to remove these deposits to restore performance. We highly recommended that only qualified service technicians perform this service. SPARK ARRESTOR The spark arrestor must be replaced every 25 hours or yearly to ensure proper performance of the product. Spark arrestors may be in different locations depending on the model purchased. Please contact the nearest service dealer for servicing your spark arrestor. The fuel cap contains a non-serviceable filter and a check valve.Acloggedfuelfilterwillcausepoorengineperformance. If performance improves when the fuel cap is loosened, the check valve may be faulty or filter clogged. Replace the fuel cap if required. STORING THE PROdUCT .Clean all foreign material from the product. Store it in a well-ventilated place that is inaccessible to children. Keep away from corrosive agents such as garden chemicals and de-icing salts. .Abide by all Federal and local regulations for the safe storage and handling of gasoline. When storing 1 month or longer: .Drain all fuel from tank into a container approved for gasoline. Run engine until it stops. WARNING: Never run the blower without the spark arrestor in place. Failure to do so could result in a fire that could cause serious personal injury. Page 1 Page 15 troubleshooting Problem Possible Cause Solution Engine will not start. No spark. No fuel. Engine is flooded. Starter rope pulls harder now than when new. Check spark. Remove spark plug. Reattach the spark plug cap and lay spark plug on metal cylinder. Pull the starter rope and watch for spark at spark plug tip. If there is no spark, repeat test with a new spark plug. Push primer bulb until bulb is full of fuel. If bulb does not fill, primary fuel delivery system is blocked. Contact a servicing dealer. If primer bulb fills, engine may be flooded, proceed to next item. Remove spark plug, turn unit so spark plug hole is aimed at the ground. Rotate the choke dial to “RUN” position and pull starter cord 10 to 15 times. This will clear excess fuel from engine. Clean and reinstall spark plug. Pull starter three times with choke dial at “RUN”. If engine does not start, rotate choke dial to “FULL CHOKE” position and repeat normal starting procedure. If engine still fails to start, repeat procedure with a new spark plug. Contact a servicing dealer. Engine starts but will not accelerate. Engine requires approximately three minutes to warm up. Allow engine to completely warm up. If engine does not accelerate after three minutes, contact a servicing dealer. Engine starts but will only run at high speed at half choke. Carburetor requires adjustment. Contact a servicing dealer. Engine does not reach full speed and emits excessive smoke. Check lubricant fuel mixture. Air filter is dirty. Spark arrestor screen is dirty. Use fresh fuel and the correct 2-cycle lubricant mix. Clean air filter. Refer to Cleaning the Air Filter Screen earlier in this manual. Contact a servicing dealer. Engine starts, runs, and accelerates but will not idle. Idle speed screw on carburetor needs adjustment. Turn idle speed screw clockwise to increase idle speed. See figure 12. Fig. 12 idle speed screw LIMITEd WARRANTy STATEMENT Homelite Consumer Products, Inc., (“Homelite”) warrants to the original retail purchaser that this HOMELITE brand outdoor product is free from defect in material and workmanship andagrees torepair or replace, at Homelite’s, discretion,any defective product free of charge within these time periods from the date of purchase. . Two years for all models if used for personal, family, or household use; . 90 days for any unit used...
Ce manuel est également adapté pour les modèles :Les systèmes de ventilation - MIGHTYLITE UT08580 (2.6 mb)