Log:
Évaluations - 2, GPA: 4 ( )

Instructions Poulan, Modèle 530088125

Fabricant : Poulan
Taille : 432.81 kb
Nom Fichier : NOUS2002_530088125.pdf
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


NOTE: If engine attempts to start before the 5th pull, go to next step immediately. 5. Move the choke lever to the HALF CHOKE position. 6. Pull the starter rope sharply until the engine runs, but no more than 5 pulls (below 30_ F, 10 pulls). 7. After a 5 second warm- --up, move the choke lever to the RUN position. 8. Allow the unit to run for 30 more seconds at the RUN position before moving the throttle lever to position. If engine has not started after 5 pulls (at HALF CHOKE), repeat STARTING A COLD ENGINE procedure. If engine still does not start, proceed to STARTING A FLOODED ENGINE. 9. To stop the engine, move the throttle lever to the STOP position. - -- STARTING A WARM ENGINE 1. Move throttle lever to the position. 2. Pull starter rope sharply until engine runs, but no more than 5 pulls. NOTE: If engine has not started, pull starter rope 5 more pulls. If engine still does not run, it is probably flooded. 3. To stop the engine, move the throttle lever to the STOP position. STARTING A FLOODED ENGINE Flooded engines can be started by placing the choke lever in the RUN position. Move throttle lever to the fast position ; then, pull rope until engine starts. After engine starts, move the throttle lever to the slow position to allow engine to idle. Starting could require pulling the starter rope many times depending on how badly the unit is flooded. If unit still doesn’t start refer to the TROUBLESHOOTING TABLE or call 1-800-554-6723. MAINTENANCE WARNING: Avoid touching muffler unless engine and muffler are cold. A hot muffler can cause serious burns. WARNING: Stop engine and be sure the impeller blades have stopped turning before opening the vacuum inlet door or attempting to insert or remove the vacuum or blower tubes. The rotating blades can cause serious injury. Always disconnect the spark plug before performing maintenance or accessing movable parts. GENERAL RECOMMENDATIONS The warranty on this unit does not cover items that have been subjected to operator abuse or negligence. To receive full value from the warranty, the operator must maintain unit as instructed in this manual. Various adjustments will need to be made periodically to properly maintain your unit. CHECK FOR LOOSE FASTENERS AND PARTS S Spark Plug Boot S Air Filter S Housing Screws S Muffler CHECK FOR DAMAGED OR WORN PARTS Contact an authorized service dealer for replacement of damaged or worn parts. S Fuel Tank - --Do not use unit if fuel tank shows signs of damage or leaks. S Vacuum Bag - --Do not use vacuum bag if it is torn or damaged. INSPECT AND CLEAN UNIT AND DECALS S After each use, inspect complete unit for loose or damaged parts. Clean the unit and decals using a damp cloth with a mild detergent. S Wipe off unit with a clean dry cloth. --7 CLEAN AIR FILTER AirFilterCoverAirFilterScrews Cleaning the air filter: A dirty air filter decreases engine performance and increases fuel consumption and harmful emissions. Always clean or replace air filter after every 5 hours of operation or yearly, whichever comes first. 1. Clean the cover and the area around it to keep debris from falling into the carburetor chamber when the cover is removed. 2. Remove parts as illustrated. NOTE: Do not clean filter in gasoline or other flammable solvent. Doing so can create a fire hazard or produce harmful evaporative emissions. 3. Wash the filter in soap and water. 4. Allow filter to dry. 5. Apply a few drops of oil to the filter; squeeze filter to distribute oil. 6. Replace parts. REPLACE SPARK PLUG Replace spark plug each year to ensure the engine starts easier and runs better. Set spark plug gap at 0.025 inch. Ignition timing is fixed, nonadjustable. 1. Twist, then pull off spark plug boot. 2. Remove spark plug from cylinder and discard. 3. Replace with Champion RCJ-6Y spark plug and tighten securely with a 3/4 in. socket wrench. 4. Reinstall the spark plug boot. - -- REPLACE FUEL FILTER To replace fuel filter, drain unit by running it dry of fuel, then remove fuel cap/retainer assembly from tank. Pull filter from tank and remove it from the fuel line. Install new fuel filter on fuel line; reinstall parts. Fuel Line Fuel Filter CHECK MUFFLER MOUNTING SCREWS Once each year, ensure muffler mounting screws are secure and tightened properly to prevent damage. MountingScrewHoles Muffler Cover Screws 1. Loosen and remove the 2 screws from the muffler cover. 2. Remove the muffler cover. 3. Tighten the 2 muffler mounting screws securely. 4. Reinstall muffler cover and 2 screws. Tighten securely. CARBURETOR ADJUSTMENTS Your carburetor is equipped with limiter caps. Adjusting the carburetor is a complicated task. We recommend that you take your unit to an an authorized service dealer. Damage will occur if you turn the needles beyond the limiter stops. STORAGE WARNING: Perform the following steps after each use: S Allow engine to cool, and secure the unit before storing or transporting. S Store unit and fuel in a well ventilated area where fuel vapors cannot re...


Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories