Log:
Évaluations - 4, GPA: 4.3 ( )

Instructions Datalogic Scanning, Modèle QUICKSCAN 6000 PLUS

Fabricant : Datalogic Scanning
Taille : 821.51 kb
Nom Fichier :
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


Please be prepared to provide information about the store/chain, location, POS system and other pertinent information about the scanner being repaired. Programming Guide 7 000 010 000 Where To Go From Here Programming is easy and straightforward if you follow these steps: 1. If you are changing interfaces, first connect the scanner to the new host using the new interface cable. Scan the interface enable bar code label1 . 2. Scan any feature labels that are unique to the interface you are currently programming. These interface specific programming labels immediately follow each interface selection label. 3. Turn to the Symbology section if you are going to change any bar code symbologies or modify any symbology related features. 4. Turn to the General Features section of this guide if you wish to change or modify any of the scanner's other features. Once the necessary changes have been made, and you have scanned the END label, you are ready to scan. 1 This step is not necessary for QuickScan 6000 Plus scanners, unless you require a specific interface sub-type such as SNI OCIA or IBM sub-type 4682/92 Port E. Interface software is automatically selected when the QuickScan 6000 Plus hardware connection (via a new interface cable) is made. 8 QuickScan 6000/6000 Plus IBM 4683/84 • 4693/94 Port 5B Interface Selection Scan this label to enable the IBM 468x Port 5B interface. IBM 4683/84 • 4693/94 Port 5B Settings Data Format: Send As Code 39 — converts bar code data (UPC/EAN, add-ons, Code 93, Codabar, MSI/Plessey and Code 128) into Code 39 format before sending the data to the host. These settings are for IBM 4683/84 • 4693/94 Port 5B interface ONLY. Limit Command Set — is an option that causes the scanner to ignore 'enable scanner' and 'disable scanner' commands sent from the host. Transmit Unsolicited Status1 — when enabled, this option causes the scanner to transmit a status message to the host upon receipt of an "SNRM". SET < a Send as Code 39 Don't Send as Code 39 Enable Limit Command Set Disable Limit Command Set- Transmit Unsolicited Status --- Don't Transmit Unsolicited Status--- END 1 For this IBM interface, the setting for Unsolicited Status is normally Enabled. Programming Guide 9 000 435 CC1 000 721 720 731 730 CC1 000 000 IBM 4683/84 • 4693/94 Port 9A, 9B, 9C, 9E I/F Selection Scan this label to enable the IBM 468x/9x Port 9x interface. IBM 4683/84 • 4693/94 Port 9A, 9B, 9C, 9E Settings Data Format: Send As Code 39 — converts bar code data (UPC/EAN, add-ons, Code 93, Codabar, MSI/Plessey and Code 128) into Code 39 format before sending the data to the host. These settings are for IBM 4683/84 • 4693/94 Port 9A, 9B, 9C, 9E interface ONLY. Limit Command Set — is an option that causes the scanner to ignore 'enable scanner' and 'disable scanner' commands sent from the host. Transmit Unsolicited Status1 — when enabled, this option causes the scanner to transmit a status message to the host upon receipt of an "SNRM". set Œ o < a Send as Code 39 Don't Send as Code 39 Enable Limit Command Set Disable Limit Command Set Transmit Unsolicited Status --- Don't Transmit Unsolicited Status--- end 1 For this IBM interface, the setting for Unsolicited Status is normally Disabled. 10 QuickScan 6000/6000 Plus 000 436 cc0 000 721 720 731 730 CC1 000 000 IBM 4682/92 Port E Interface Selection Scan this label to enable the IBM 468x/9x Port E interface. IBM 4682/92 Port E Settings Data Format: Send As Code 39 — converts bar code data (UPC/EAN, add-ons, Code 93, Codabar, MSI/Plessey and Code 128) into Code 39 format before sending the data to the host. These settings are for IBM 4682/92 Port E interface ONLY. Limit Command Set — is an option that causes the scanner to ignore 'enable scanner' and 'disable scanner' commands sent from the host. Transmit Unsolicited Status1 — when enabled, this option causes the scanner to transmit a status message to the host upon receipt of an "SNRM". set < a Send as Code 39 Don't S end as Code 39 Enable Limit Command Set Disable Limit Command Set- Transmit Unsolicited Status --- Don't Transmit Unsolicited Status--- end 1 For this IBM interface, the setting for Unsolicited Status is normally Disabled. Programming Guide 11 000 4310 000 731 730 CC1 000 720 000 Datalogic OCIA1 Interface Selection Scan this label to enable the Datalogic OCIA interface. NCR OCIA Eight Bit (short format) Interface Selection Scan this label to enable the NCR OCIA (short format) interface. NCR OCIA Nine Bit (long format) Interface Selection Scan this label to enable the NCR OCIA Nine Bit (long format) interface. SNI OCIA Interface Selection Scan this label to enable the SNI OCIA interface. 1 NOTE: In previous publications, this Interface was termed, "SP OCIA". 12 QuickScan 6000/6000 Plus 000 431 000 000 432 000 000 434 000 000 433 000 OCIA Options Use these labels to change the se...

Ce manuel est également adapté pour les modèles :
Scanner / Copieur / MFP - QUICKSCAN 6000 (821.51 kb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories