Log:
Évaluations - 3, GPA: 4 ( )

Instructions Cannon, Modèle C60DT

Fabricant : Cannon
Taille : 498.44 kb
Nom Fichier : C60DPC_C60DPX_C60DTC_C60DTX_19505773201.pdf
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


Remove all doors and lids. Remove the mains cable (where fitted) by cutting off flush with the appliance and always ensure that no plug is left in a condition where it could be connected to the electricity supply. To help the environment, Local Authority instructions should be followed for the disposal of you product. Disposal of old electrical appliances The European Directive 2002/96/EC on Waste Electrical and Electronic Equipment (WEEE), requires that old household electrical appliances must not be disposed of in the normal unsorted municipal waste stream. Old appliances must be collected separately in order to optimise the recovery and recycling of the materials they contain and reduce the impact on human health and the environment. The crossed out “wheeled bin” symbol on the product reminds you of your obligation, that when you dispose of the appliance it must be separately collected. Consumers should contact their local authority or retailer for information concerning the correct disposal of their old appliance. INSTALLATION INSTRUCTIONS Prior to installation, ensure that the local distribution conditions (nature of the gas and gas pressure) and the adjustment conditions are compatible. The adjustment conditions for this appliance are stated on the data badge which is fitted on the back panel. This appliance is not designed to be connected to a combustion products evacuation device. It must be installed and connected in accordance with current installation regulations. particular attention should be given to the relevant requirements regarding ventilation. MODEL NUMBERS C60DP, C60DT Category II2H3+ (GB) These models are set to burn NATURAL GAS (G20) at 20 mbar but can be converted for use on BUTANE (G30) at 28-30mbar or PROPANE (G31) at 37mbar with the use of the LPG conversion kit supplied with the cooker. GAS SAFETY (INSTALLATION & USE) REGULATIONS It is the law that all gas appliances are installed by competent persons in accordance with the current edition of the above regulations. It is in your interest and that of safety to ensure compliance with the law. In the UK, CORGI registered installers work to safe standards of practice. The cooker must also be installed in accordance with BS 6172. Failure to install the cooker correctly could invalidate the warranty liability claims and could lead to prosecution. LOCATION The cooker may be located in a kitchen, kitchen/diner or a bed-sitting room, but not in a room containing a bath or shower. The cooker must not be installed in a bed-sitting room of less than 20m3. When adjusted for use on Butane (G30) or Propane (G31), the cooker must not be installed in a room or internal space below ground level, e.g. in a basement. PROVISION FOR VENTILATION The room containing the cooker should have an air supply in accordance with BS 5440: Part 2. The room must have an opening window or equivalent; some rooms may also require a permanent vent. If the room has a volume between 5 and 10m3, it will require an air vent of 50cm2 effective area unless it has a door which opens directly to outside. If the room has a volume of less than 5m3, it will require an air vent of 100cm2 effective area. If there are other fuel burning appliances in the same room, BS 5440: Part 2 should be consulted to determine air vent requirements. INSTALLATION INSTRUCTIONS TECHNICAL DATA Gas connection Rp 1/2 (1/2” BSP female) Pressure test point Front left hotplate injector Gas rate adjustment None Aeration adjustment None Electrical connection 4mm2 twin and earth 230/240V a.c. 50Hz. Professional 60 C60DP G20 at 20mbar G30 at 28-30mbar G31 at 37mbar BURNER HEAT INPUT INJECTOR HEAT INPUT INJECTOR HOTPLATE Front left 4.1 kW 100 + 72 + 100 3.8 kW (275g/h) 63 + 42 + 63 HOTPLATE Rear right 3.0 kW 116 3.0 kW (220g/h) 86 HOTPLATE Front right and Rear left 2.0 kW 103 2.0 kW (145g/h) 70 Total load 4.5 / 4.9 kW Traditional 60 C60DT G20 at 20mbar G30 at 28-30mbar G31 at 37mbar BURNER HEAT INPUT INJECTOR HEAT INPUT INJECTOR HOTPLATE Front left and rear right 3.0 kW 116 3.0 kW (220g/h) 86 HOTPLATE Front right and rear left 2.0 kW 103 2.0 kW (145g/h) 70 Total load 4.5 / 4.9 kW INSTALLATION INSTRUCTIONS SPACE FOR FIXING The cooker can be close fitted below hotplate level. This requires a minimum distance of 600mm between cupboard units of hotplate height. When installing next to a tall cupboard, partition or wall, for a minimum distance of 400mm above hotplate level, allow a side clearance of at least 65mm. The diagram below illustrates the minimum clearance between the cooker and adjacent walls, cupboards etc. The wall behind the cooker, 50mm below and 450mm above, and the width of the cooker, must be a non-combustible material such as ceramic wall tiles. If the cooker is to be fitted close to a corner on the left hand side, ensure that there is a clearance of at least 50mm to allow the main oven door to open fully for when removing oven shelves. 65 mm Min400 mm Min750mm min 600 mm Min COOKER HOODS If a coo...

Ce manuel est également adapté pour les modèles :
Autocuiseurs - C60DP (498.44 kb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories