Log:
Évaluations - 4, GPA: 4.5 ( )

Instructions Bunn, Modèle JDF-2N

Fabricant : Bunn
Taille : 1.34 mb
Nom Fichier : 38310.0000.pdf
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


Reconnect any connections to ambient product containers. 25. Prime the pumps as described in “PRIMING” in the Initial Fill Section. CLEANING (cont) 39689.0000 Tube Kit JDF-2S & JDF-4S 39687.0000 Tube Assembly 38310 012207 ADJUSTMENT & OPTIONAL SETTINGS Total Dispense Ratio Set Up Procedure 1. Adjust water flow as described in Water Flow Testing and Adjustment. Record water output setting for later reference on each dispense head. 2. Enter program mode by simultaneously pressing both hidden switches. 3. Press and hold the dispense button, you will hear 5 beeps then two short beeps, continue holding until you hear three short beeps. At this time the dispenser will run product and water for 3 seconds. 4. Record the total ounces dispensed. 5. Refer to the Brix/Ratio chart below to confirm proper total dispensed amount for ratio desired and water output previously recorded. 6. To increase or decrease the product output, refer to Pump Speed Programming section. * * Always dispense 12 ounces of finished product after making a pump speed adjustment before taking an additional sample for the brix/ratio check. Ratio Target 2:1 3:1 4:1 5:1 6:1 7:1 8:1 9:1 10:1 11:1 12:1 13:1 14:1 15:1 1.5 2.25 2.00 1.88 1.80 1.75 1.71 1.69 1.67 1.65 1.64 1.63 1.62 1.61 1.60 1.75 2.63 2.33 2.19 2.10 2.04 2.00 1.97 1.94 1.93 1.91 1.89 1.88 1.88 1.87 2.0 3.00 2.67 2.50 2.40 2.33 2.29 2.25 2.22 2.20 2.18 2.17 2.15 2.14 2.13 2.25 3.38 3.00 2.81 2.70 2.63 2.57 2.53 2.50 2.48 2.45 2.44 2.42 2.41 2.40 2.5 3.75 3.33 3.13 3.00 2.92 2.86 2.81 2.78 2.75 2.73 2.71 2.69 2.68 2.67 2.75 4.13 3.67 3.44 3.30 3.21 3.14 3.09 3.06 3.03 3.00 2.98 2.96 2.95 2.93 3.0 4.50 4.00 3.75 3.60 3.50 3.43 3.38 3.33 3.30 3.27 3.25 3.23 3.21 3.20 3.25 4.88 4.33 4.06 3.90 3.79 3.71 3.66 3.61 3.58 3.55 3.52 3.50 3.48 3.47 3.5 5.25 4.67 4.38 4.20 4.08 4.00 3.94 3.89 3.85 3.82 3.79 3.77 3.75 3.73 3.75 5.63 5.00 4.69 4.50 4.38 4.29 4.22 4.17 4.13 4.09 4.06 4.04 4.02 4.00 4.0 6.00 5.33 5.00 4.80 4.67 4.57 4.50 4.44 4.40 4.36 4.33 4.31 4.29 4.27 4.25 6.38 5.67 5.31 5.10 4.96 4.86 4.78 4.72 4.68 4.64 4.60 4.58 4.55 4.53 4.5 6.75 6.00 5.63 5.40 5.25 5.14 5.06 5.00 4.95 4.91 4.88 4.85 4.82 4.80 4.75 7.13 6.33 5.94 5.70 5.54 5.43 5.34 5.28 5.23 5.18 5.15 5.12 5.09 5.07 5.0 7.5 6.67 6.25 6.00 5.83 5.71 5.63 5.56 5.50 5.45 5.42 5.38 5.36 5.333 secondwater dispense(oz) Dispensed product (oz) Temperature Compensated Refractometer Method 1. Adjust the water flow as described in Water Flow Testing and Adjustment. 2. Place an empty container under the appropriate dispense nozzle. 3. Dispensers with Press and Hold Feature: Press and hold the “Product Dispense Switch” Fig 5, until water and concentrate begin flowing freely from the dispense nozzle. Dispensers with Portion Control Feature: Press and hold the “+/Stop Switch” Fig 6, until water and concentrate begin flowing freely from the dispense nozzle. 4. Discard the product caught previously and place the empty container back under the dispense nozzle. 5. Dispensers with Press and Hold Feature: Press and hold the “Product Dispense Switch” until the cup is filled. Dispensers with Portion Control Feature: Press and hold the “+/Stop Switch” until the cup is filled. 6. Stir the contents of the cup, and use the refractometer (according to the manufacturer’s instructions) to check the brix %. 7. Adjust the pump speed (down to decrease the brix %; up to increase the brix %) to achieve the correct brix % as described in Pump Speed Programming. 38310 092905 ADJUSTMENT & OPTIONAL SETTINGS (cont) Water Flow Testing and Adjustment 1. Enter the “Pump Speed Programming” mode by simultaneously pressing both “Hidden Switches” Fig 5 or Fig 6. Note that the beeper sounds twice and that the “PROGRAM” indicator begins flashing. 2. Place a graduated measuring cup or the large chamber of the empty brixing cup (BUNN-O-MATIC part number 33095.0000) under the appropriate dispense nozzle. 3. Press and hold the desired “Product Dispense Switch” Fig 5 (“+/Stop Switch” Fig 6, for portion control dispensers) for 5 seconds. Note that the beeper sounds once per second (6 times, total) during this period. 4. At the end of the 5 second period, the selected position will dispense water (no concentrate) for only 3 seconds. 5. Measure the water dispensed. 6. Adjust the water flow rate Fig 8, (clockwise to increase flow rate; counterclockwise to decrease flow rate) to the corresponding product mix ratio as follows: FIG 7 Adjusting Water Flow Using 1/4” allen wrench Mix Ratio Adjust water flow rate to: Product Brix % (water + concentrate) 2+1 *3.75 fluid ounces (111 ml) Prune Juice 16.0% per 3-second test Other * Orange Juice 11.8% 4+1 Pineapple Juice 12.8% Cranberry Fruit Cocktail 14.0% *4.0 fluid ounces (118 ml) Grapefruit Juice 10.6% per 3-second test Lemonade 5+1 Apple Juice 12.0% Fruit Punch Grape Juice 13.0% 3+1 through 7+1 Other * Above 7+1 *4.0 fluid ounces (118 ml) Other * per 3-second test High Viscosity Juice 2.25-3.0 fl.oz. (66.5-89ml) As Required - per 3-second ...


Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories