|
Facilité d'utilisation
(30m) @3A 25 ft. (7m) @2A 35 ft. (10m) @1A 75 ft. (23m) Communication RS232 Null Modem Cable 50 ft. (15m) N/A Communication IGM422 SiteScan 18-22 AWG Stranded & Shielded 22 AWG (recommended) Non Plenum - Belden 9461 Plenum - Belden 88761 1000 ft. (300m) N/A Communication EIA485 18-22 AWG Stranded & Shielded 22 AWG (recommended) Non Plenum - Belden 9461 Plenum - Belden 88761 3000 ft. (900m) N/A Phone/ModemLine 4 Wire (Pins 3 & 4) RJ11 Connector N/A N/A 24VAC Power Connection 18-22 AWG Stranded & Shielded 18 AWG (recommended) Non Plenum - Belden 8770 Plenum - Belden 88770 150 ft. (45m) 24VAC @1.3A Power Connections (Transformer Module) 115VAC 14 AWG Stranded & Unshielded Non Plenum - Belden 5101UE 150 ft. (45m) 115VAC @5A 230VAC 14 AWG Stranded & Unshielded Non Plenum - Belden 5101UE 150 ft. (45m) 230VAC @0.5A 3 Specifications Small Enclosure Large Enclosure I/O Expansion Module UMS02400 115VAC UML11500 230VAC UML23000 UMEXP Input PowerRequirements 24VAC±10% of nominal; 50/60 Hz, 1.3A, 30VA 115VAC±10% of nominal; 60Hz, 4A, 460VA 230VAC±10% of nominal; 50Hz, 0.5A, 115VA 24VAC±10% of nominal; 50/60 Hz, 0.6A, 15VA, Class 2 Dimensions W x D x H, in. (mm) 14-1/4 x 2-3/4 x 12(361.95 x 69.85 x 304.8) 18 x 2-3/4 x 18(457.2 x 69.85 x 457.2) 14-1/4 x 2-3/4 x 12(361.95 x 69.85 x 304.8) Weight (Assembled) 7.68 lb. (3.48 kg) 20.56 lb. (9.33 kg) 7.68 lb. (3.48 kg) Enclosure Type NEMA 1 NEMA 1 Liquid Crystal Display Four line, 20 character, backlit . Mounting Surface Building Wall or Structural Member Ambient OperatingEnvironment 32°F to 104°F (0°C to 40°C) 0% RH to 95% RH (non-condensing) Modem/Clock Specifics . Modem Type Embedded 14.4K bps . Clock Type Real-Time Clock . Clock battery backup type Lithium Cell (non-replaceable) . Clock battery life 7 years, constant, no power . Modem battery backup type Nickel Cadmium (replaceable) . Modem battery life 10 minutes at full load . Communications . Local EIA232 . Remote: Modem Baud rate 9600 bps; Parity=None; Data bits=8; Stop bits=1 . Remote: Supported pagers 9600 E-7-1 supports TAPI protocol version 1.8 . SiteScan Web IGM Protocol, EIA422 . Expansion Board (optional) EIA485 EIA485 Agency Listings UL UL3121 UL1012 UL1585 . CSA C22.2 No. 1010 C22.2 No. 66 and C22.2 No. 107.1 . CE Yes Yes . FCC Compliance CFR 47 Part 15 N/A . Inputs & Outputs (Quantity) Digital Inputs Dry Contact Closure24VDC, 10 mA (8) Dry Contact Closure24VDC, 10 mA (16) Analog Inputs 4-20mA signal input with selectable power source of 12VDC or 24VDC (4) . Digital Outputs 24VAC, 3A (8) 240VAC, 2A (8) Common Alarm Outputs 24VAC, 3A (2) . Ordering Information Quantity Product # Description UMS02400 Universal Monitor small enclosure UML11500 Universal Monitor large enclosure with 115VAC Transformer Module UML23000 Universal Monitor large enclosure with 230VAC Transformer Module TM115 Transformer Module 115VAC with two 24VAC outputs (40VA each) and 115VAC receptacle TM230 Transformer Module 230VAC with two 24VAC outputs (40VA each) UMEXP I/O Expansion ...
Ce manuel est également adapté pour les modèles :Téléphones cellulaires - Liebert TM115 (747.09 kb)
Téléphones cellulaires - Liebert TM230 (747.09 kb)
Téléphones cellulaires - Liebert UML23000 (747.09 kb)
Téléphones cellulaires - Liebert UMS02400 (747.09 kb)