Log:
Évaluations - 3, GPA: 5 ( )

Instructions Humax, Modèle F1-5000

Fabricant : Humax
Taille : 2.38 mb
Nom Fichier :
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


If the satellite name you require is not available, please use other. In installer mode the Satellite Name Reference refers to the 0 position of the motor. Movement In user mode this is used to fine-tune the position of the motor for better reception. In Installer mode this is used to search for the position of a satellite manually. Motor Control Search : Searches for services on the chosen transponder. Goto : Moves the motor to the stored position of the selected satellite name. Store : Stores the current position of the motor for the selected satellite name. Reset : Resets all stored positions of the motor relative to the 0 position. (Installer mode only) DiSEqC Command Mode Changes the current mode between Installer and User. You must set your receiver up so that it is ready to use DiSEqC 1.2. To do so, do as follows 1. Press the MENU( )button, to display the Main Menu. 2. Select Service Searching option and press OK button, to display the Service Searching menu. 3. Select Antenna Setting option and press OK button, to display the Antenna Setting menu. 4. You must set up a separate antenna alternative for each satellite position required. 5. Select the name of the satellite you wish to use. 6. Select the correct LNB frequency for the LNB you are using. 7. Set the Motorised System to Enable using the buttons. 8. The option DiSEqC Input Selection should now be disabled. This option is used for DiSEqC 1.0 and cannot be used in conjunction with DiSEqC 1.2. Your receiver is now ready to use DiSEqC 1.2. To return to the Main Menu, use the EXIT button until you are at the Main Menu. 2. Setting your Receiver for DiSEqC 1.2 E42 Motorised System 3. Initial Satellite Position Search 4. Motor Limit Setting This is required when you first set your receiver up to use DiSEqC 1.2 and sets the positions of all pre-programmed satellites. 1. Make sure your motor is installed correctly with the calibrations adjusted for the region you are situated. (Please consult the user manual for your motor.) 2. Make sure your receiver is set up to use DiSEqC 1.2. (see section 2 above). 3. On the Main Menu, select Service Searching option and press the OK button, you should now see the Service Searching menu. 4. Highlight the option Antenna Alternative and press the OK button to display the Satellite Setting menu. 5. Highlight the DiSEqC Command Mode option and use the buttons to change the value to Installer and press the OK button. 6. Highlight the Motor Control option and use the buttons to change the value to reset and press the OK button. 7. You will now see a warning message, press the button to continue. All motor positions of the pre-programmed satellites should now be correct. If you have any other make or model of DiSEqC 1.2 motor then you may need to store the satellite positions in yourself(Please refer to the user manual for your motor). 8. Highlight the DiSEqC Command Mode option and use the buttons to change the value to User and press the OK button. 9. You should now be ready to start storing services for the various satellites(see 5 onwards). Use this option to set the East and West limits of the motor This should be used to prevent your dish from hitting anything that may be obstructing the path of the dish. 1. On the Main menu, select Service Searching option and press the OK button. ou should now see the Service Searching menu. 2. Select Manual Search option and press the OK button, you should now see the Manual Search menu. 3. Highlight the Alternative option and press the OK button. You should now be in the Satellite Settings menu. 4. Press the button to access the Motor Limit Setting menu. 5. Highlight the Limit Setting option and use the buttons to disable this. (Warning: When this option is disabled your motor will be able to move beyond any limits that have been stored - please take care in case there are anything obstructing the path of your dish.) 6. To set the East Limit: a) Select Movement and use the buttons to move your motor East or West until the motor is at the position you wish to use as your East Limit. Use the buttons to stop the motor at the correct position. b) Highlight the Store East Limit option and press the OK button to store the current position as your East Limit. E43 To set the West Limit: a) Select Movement and use the buttons to move your motor East or West until the motor is at the position you wish to use as your West Limit. Use the buttons to stop the motor at the correct position. b) Highlight the Store West Limit option and press the OK button to store the current position as your West Limit. The purpose of this is to set the motor position for each satellite manually. This is useful if the satellite you require is not available from the pre-programmed list(see 3 above). To do this, you must access the Satellite Settings menu. Do as follows; 1. Select Service Searching from the main menu and press the OK button, to display the Service Searching menu. 2. Select the Manual Search opti...

Ce manuel est également adapté pour les modèles :
Récepteurs Satellite - CI-5100 (2.38 mb)
Récepteurs Satellite - NACI-5700 (2.38 mb)
Récepteurs Satellite - VA-5200 (2.38 mb)
Récepteurs Satellite - VACI-5300 (2.38 mb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories