Log:
Évaluations - 3, GPA: 4 ( )

Instructions Fisher & Paykel, Modèle DE62T27C

Fabricant : Fisher & Paykel
Taille : 1.57 mb
Nom Fichier :
Langue d'enseignement: enes
Aller à la télécharger



Facilité d'utilisation


Exhaust duct systems longer than specified will: Accumulate lint creating a potential fire hazard. Shorten the life of the dryer. Reduce performance, resulting in longer drying times and an increased energy usage. 2 Determine the number of elbows/bends you will need. 3 In the column listing the type of metal duct you are using (rigid or thick wall flexible metal), find the maximum length of metal duct on the same line as the number of elbows/bends to be used (refer to page 15). 15Installation instructions Maximum length of exhaust duct Preferred 4” Hoods When you have a 4” (100 mm) Hood Acceptable 2 .” Hood When you have a 2 .” (60 mm) Hood For exhaust systems not covered by the exhaust duct length charts (such as multiple unit hook-ups, plenums, and power-assist fans), call our Customer Care Center: TOLL FREE 1 888 9 FNP USA (1 888 9 367 872). EN Maximum length of exhaust duct Preferred 4” Hoods When you have a 4” (100 mm) Hood Acceptable 2 .” Hood When you have a 2 .” (60 mm) Hood For exhaust systems not covered by the exhaust duct length charts (such as multiple unit hook-ups, plenums, and power-assist fans), call our Customer Care Center: TOLL FREE 1 888 9 FNP USA (1 888 9 367 872). EN Maximum length of 4” diameter metal duct. Number of 90. elbows/bends Rigid Thick Wall Flexible Metal (fully extended) 0 64 ft 19.5 m 36 ft 10.9 m 1 54 ft 16.5 m 31 ft 9.4 m 2 44 ft 13.4 m 27 ft 8.2 m 3 35 ft 10.6 m 25 ft 7.6 m 4 27 ft 8.2 m 23 ft 7.0 m Maximum length of 4” diameter metal duct. Number of 90. elbows/bends Rigid Thick Wall Flexible Metal (fully extended) 0 58 ft 17.6 m 28 ft 8.5 m 1 48 ft 14.6 m 23 ft 7.0 m 2 38 ft 11.5 m 19 ft 5.7 m 3 29 ft 8.8 m 17 ft 5.1 m 4 21 ft 6.4 m 15 ft 4.5 m 16 Installation instructions Alternative installation for close clearances Venting systems come in many varieties. Select the type best for your installation. A close-clearance installation is shown. sections separate, fittings can face same or opposite swivel collar Extra long band–clamp for dryer connection swivel collar wall connection telescoping sections beveled edges allow corner installations Fig.13 Close-clearance installation Fig.14 Installation configuration The maximum length using a 2” x 6” (50 mm x 150 mm) rectangular duct with two elbows and a 2 .” (63 mm) exhaust hood is 8 ft (2.4 m). Refer to the venting system kit manufacturers instructions. WARNING! Fire Hazard Use heavy metal exhaust duct. Do not use a plastic exhaust duct. Do not use thin metal foil exhaust duct. Failure to do so can result in death or fire. 17 Exhaust venting1 Read the exhaust section (pages 12 – 15) before installing the exhaust system to determine the maximum allowable exhaust duct length. Do not use sheet metal screws when assembling ducting. Always use suitable duct tape. Never use plastic or thin metal foil flexible exhaust material. 2 The exhaust outlet is located close to the center of the rear of the dryer. Make sure you join the exhaust duct to the dryer with duct tape only. This will prevent lint and dust from escaping from the dryer and exhaust system. Fig.15 Exhaust venting dimensions Exhaust outlet Does not include foot height 13 1.8” (333 mm) 13 7.8” (352 mm) 4 3.8”(111 mm) 3 The exhaust vent can be routed up, down, left, right or straight out the back of the dryer. Refer to diagram. Fig.16 Venting options Installation instructions EN 18 Installation instructions Installation Parts and literature are packaged inside the dryer drum. WARNING! Excess Weight Hazard Use two or more people to move and install the dryer. Failure to do so can result in back or other injury. Only remove the packaging at the customer’s premises. This will ensure the appliance arrives in pristine condition and reduces the risk of damage when transporting to the customer’s home. Unpacking Make sure dryer is in a suitable location for installation. Consider installing the dryer before the washing machine in a side by side installation, this will allow better access to electrical and exhaust connections. Remove packaging 2. Unfold the bottom flaps on the carton. 3. Unfold the top flaps on the carton, remove top packer. 2. 3. 5. Remove the basepacker by tilting the product 6. Remove the drum back and walking the product off it. from the lint collector packer and the tape bucket in the drum. Tilt Walk off Slide out 5. 6. 1. 1. Remove straps. 4. 4. Remove the carton by lifting it off the product (do not cut the carton off ). 19 Installation instructions Fitting the front feet Note: Dryer is usually supplied with feet fitted and protruding the correct distance. 1 Tilt the dryer back using a hand trolley and making sure the trolley and dryer are secure. 2 Fit a rubber insert to each plastic foot as shown. Fig.18 Adjusting feet Fig.17 Inserting rubber inserts Screw the feet into the foot retainers on the left hand and right hand sides as shown. EN Screw both feet in so they protrude .” (12 mm) below the bottom of the wall on the foot retainers. Fig.19 Final foot ...

Ce manuel est également adapté pour les modèles :
Rondelles - DE27C (1.57 mb)
Rondelles - DG27C (1.57 mb)
Rondelles - DG62T27C (1.57 mb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories