Facilité d'utilisation


CONTROL PANEL 1 2 1 2 3 1 PLATE ASSEMBLY (TOP) PANEL ASSEMBLY (CONTROL) Hook Unscrew 2 screws on the back of the top plate. Pull the top plate backward and upward as shown. Disconnect the PWB assembly connector from Main lead wire assembly. Pull out the drawer and unscrew 2 screws. Push upper hooks down on the top and pull the control panel. Disconnect the PWB assembly (Main & Display) from control panel by unscrewing 7 screws. 26 DISPENSER ASSEMBLY DISPENSER ASSEMBLY PUSH DRAWER Option DISPENSER ASSEMBLY DISPENSER ASSEMBLY PUSH DRAWER Option 1 2 3 1 1 Disassemble the top plate assembly. Pull out the drawer to arrow direction. Unscrew 2 screws. The hose clamps and the hose are disassembled. The ventilation bellows and the water inlet bellows are disassembled on the tub. 27 INLET VALVE INLET VALVE 1 Disconnect the wiring receptacle. LOWER COVER VALVE #1 (MAIN) VALVE #2 (PRE) VALVE #3 (HOT) White / Black - Black Gray / White - Black Blue / Red - Black 3 1 2 Unscrew 2 screws from the back. When reconnecting the connector Open the lower cover cap by using coin and pull out the lower cover to the arrow direction after a screw is unscrewed. DOOR 1 2 Open the door completely. Remove the two screws from the hinge. . When removing the door assembly, it is necessary to hold the bracket that is inner of the cabinet cover. 28 1 Take apart the cabinet gasket clamp. 2 Unscrew 2 screws from the cabinet cover. 4 Take apart the lower cover. 3 Open the lower cover cap and unscrew 1 screw inside. 1 Disassemble the control panel. (page 18) 2 Unscrew all the screws on the upper and lower sides of the cabinet cover. 1 Take apart the tub gasket clamp. 2 Make sure that the drain hole of the gasket is put beneath when reassembling the gasket. .efer to the arrow mark on the tub cover. GASKET ASSEMBLY 1 Take apart the cabinet gasket clamp. 2 Unscrew 2 screws from the cabinet cover. 4 Take apart the lower cover. 3 Open the lower cover cap and unscrew 1 screw inside. 1 Disassemble the control panel. (page 18) 2 Unscrew all the screws on the upper and lower sides of the cabinet cover. 1 Take apart the tub gasket clamp. 2 Make sure that the drain hole of the gasket is put beneath when reassembling the gasket. .efer to the arrow mark on the tub cover. GASKET ASSEMBLY 29 1 Remove the BACK COVER. 2 Unscrew the bolt to pull out the ROTOR assembly. ROTOR ASSEMBLY, STATOR ASSEMBLY, FRICTION DAMPER ASSEMBLY Rotor Bolt 1 Remove the BACK COVER. 2 Unscrew the bolt to pull out the ROTOR assembly. ROTOR ASSEMBLY, STATOR ASSEMBLY, FRICTION DAMPER ASSEMBLY Rotor Bolt (ROTOR ASSEMBLY) 1 2 3 (1) Disconnect the wiring connector. Unscrew 6 bolts from the STATOR. Remove the STATOR. Note : Hook of connector (1) is on the backside (STATOR ASSEMBLY) 1 2Hinge, Damper Damper (DAMPER) Pull out the hinge, pressing its snap. Do not use the pulled-out hinge again. It may be taken off during operation. Clean the drain pump filter Open the lower cover cap ( 1 ) by using a coin. Turn the drain plug ( ) to pull out the hose. Unplug the drain plug ( 2 ) , then the water flows out, At this time use a vessel to prevent water from flowing on the floor. If the water does not flow any more, turn the pump filter ( 3 ) open to the left. Take out any foreign material from the pump filter ( 3 ). After cleaning, turn the pump filter( ) clockwise and insert the drain plug ( 2 ) to the original place. close the lower cover cap. 30 PUMP Pump Outlet Hose PUMP Pump Outlet Hose 1 2 3 4 5 6 Tub Pump Bellows Remove pump outlet hose. Remove tub pump bellows. Remove cap (Remaining Hose.) Disconnect the wiring. Unscrew 2 screws. Remove the pump. Loosen the M6 heater nut to pull out the heater. HEATER 1 CAUTION When mounting the heater, be sure to insert the heater into the heater clip on the bottom of the tub. THERMISTOR 1 2 Pull it out by holding the thermistor bracket. If it is pulled by the wire, it may be broken. When mounting the thermistor again, make sure that it is got back tight to the bushing. 31 SWITCH ASSEMBLY, DOOR LOCK 1 2 3 SWITCH ASSEMBLY, DOOR LOCK 1 2 3 Take apart the cabinet cover clamp and release the gasket. Unscrew 2 screws holding the door lock. Disconnect the door lock from the wiring connector. WHEN FOREIGN MATERIAL IS STUCK BETWEEN DRUM AND TUB 1 Remove the heater. 2 Remove the foreign material (wire, coin and others) by inserting a long bar through the hole. 32 10-1.THE EXPLODED VIEW OF CABINET ASSEMBLY 39 10. EXPLODED VIEW A150 A152 A140 A153 A151 A134 COLD (BLUE) A276 A303 A133 A130 A131 A141 A154 A110 A101 A100 A430 A485 A440 A102 A104 A103 A410 A300 A310 A220 40 F321 F322 F462 F300 F225 F220 F120 F210 F441 F430 F432 F160 F215 A450 F110 10-2THE EXPLODED VIEW OF CONTROL PANEL & DISPENSER ASSEMBLY F464 F310 10-3 THE EXPLODED VIEW OF DRUM & TUB ASSEMBLY 41 K351 K350 K360 K143 K123 K121 K122 K125 K320 K310 K105 K610 K611 K115 K131 K530 K130 F140 K411 K410 F320 F466 K...

Ce manuel est également adapté pour les modèles :
Rondelles - F1020NDR (2.12 mb)
Rondelles - F1020NDR5 (2.12 mb)
Rondelles - F1020TDR (2.12 mb)
Rondelles - F1220NDR (2.12 mb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories