Log:
Évaluations - 5, GPA: 3.6 ( )

Instructions GE, Modèle GE Unitized Spacemaker WSM2700T

Fabricant : GE
Taille : 92.8 kb
Nom Fichier : fe7dcf65-5776-4e68-86d0-e79675ef70e2.pdf
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


Gas rated input 10,500 BTU/HR. Factory equipped for natural gas. Tested for LP gas. Gas Requirements: WSM2480T. LP gas supply requires a conversion kit. Have a qualified gas technician install a conversion kit before use. Exhaust Information: Exhausting the dryer to the outside is strongly recommended to prevent large amounts of moisture and lint from being blown into the room. Closet installations must be exhausted to the outside. Installation Information: For complete information, see installation instructions packed with the product. For answers to your Monogram,® GE Profile Performance Series,™ GE Profile™ or GE appliance questions, call GE Answer Center® service, 800.626.2000. R Listed by Underwriters Laboratories GE Appliances WSM2480T—GE Unitized ® Compact Capacity Gas and Dryer B 4 A 2-1/2 Domestic Dryer Models Spacemaker ® Models DSKS433ET WSM2780T Spacemaker ® Model DSKP233ET Spacemaker ® Model WSM2700T Spacemaker ® Models WSM2420T WSM2480T Revised 11/98 Number of 90° Turns 0 1 2 3 0 1 3 0 1 2 3 0 1 2 Best Performance Maximum Length of 4" Dia. Rigid Metal Duct Exhaust Hood Type Cat. No. WX8X59 (Preferred) A 4" Opening 46 ft. 38 ft. 31 ft. 24 ft. 43 ft. 33 ft. 23 ft. 56 ft. 46 ft. 34 ft. 32 ft. 43 ft. 33 ft. 23 ft. B 2-1/2" Opening 37 ft. 30 ft. 22 ft. 15 ft. 36 ft. 26 ft. 16 ft. 42 ft. 36 ft. 28 ft. 18 ft. 36 ft. 26 ft. 16 ft. For complete information, see installationinstructions packed with your dryer. Ducting Materials: For best performance, this dryer should be vented with 4” diameter be used, then “flexible Maximum Length of 4" all metal” venting can be used, but it will reduce the maximum recommended Dia. Rigid Metal Duct Exhaust Length Calculation: Exhaust Hood Type Cat. No. WX8X59 (Preferred) A 4" Opening 30 ft. 25 ft. 20 ft. 16 ft. 30 ft. 24 ft. 16 ft. 30 ft. 22 ft. 16 ft. 10 ft. 30 ft. 24 ft. 16 ft. 1. Determine the number of 90° turns needed for your installation. If you exhaust to the side or bottom of dryer, add one turn. 2. The maximum length of 4’ rigid (aluminum or galvanized) duct which can be tolerated in the table. The maximum length for flexible ducts are less than for rigid duct. B A turn of 45° or less may be ignored. Two 45° turns within the duct length should be treated as a 90° elbow. A turn over 45° should be treated 2-1/2" as a 90° elbow. Opening Exhausting the dryer to the outside is strongly recommended to prevent large amounts of moisture and lint from being blown into the room. 24 ft. Gas dryers or any dryer located in a closet must be exhausted to the outside. 20 ft. Caution: For personal safety do not terminate exhaust into a chimney, under any enclosed house floor (crawl space), or into an attic, since the 14 ft. accumulated lint could create a fire hazard or moisture could cause damage. Never terminate the exhaust with a 10 ft. kitchen exhaust, since the combination of lint and grease could create a fire hazard. 24 ft. 18 ft. Exhaust ducts should be terminated in a dampered wall cap to prevent back dra...

Ce manuel est également adapté pour les modèles :
Rondelles - GE Unitized Spacemaker WSM2480T (92.8 kb)
Rondelles - GE Unitized Spacemaker WSM2780T (92.8 kb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories