Facilité d'utilisation
Make sure all screws and caps are securely tightened. 5. NEVER USE TOOL IF trigger or compression mechanism are inoperable, missing or damaged. Do not alter or remove trigger or other components. Make daily inspections for free movement of trigger and compression mechanism. Do not use tool if trigger can be pulled without tool being fully compressed. 6. DO NOT USE TOOL WITHOUT SAFETY WARNING LABEL. If label is missing, damaged or unreadable, contact your Porter-Cable Service Center for a replacement. 2 7. USE TOOL IN WELL VENTILATED AREA. Tool produces carbon monoxide. 8. ONLY USE PARTS, FASTENERS, FUEL CELLS, AND ACCESSORIES recommended by Porter-Cabie. 9. ALWAYS ASSUME THE TOOL CONTAINS FASTENERS. Keep the tool pointed away from yourself and others at all times. No horseplay. Respect the tool as a working implement. 10. DO NOT LOAD FASTENERS with tool in compressed position, to prevent unintentional firing of a fastener. 11. REMOVE FINGER FROM TRIGGER when not driving fasteners. Never carry tool with finger on trigger: tool may fire a fastener if compressed. 12. DON’T OVERREACH. Keep proper footing and balance at ail times when using or handling the tool. 13. FIRE FASTENERS INTO WORK SURFACE ONLY; never into materials too hard to penetrate. Never fire tool away from work surface. 14. HOLD TOOL FIRMLY to minimize recoil. 15. DO NOT DRIVE FASTENERS on top of other fasteners, or with the tool at too steep an angle: the fasteners can ricochet causing personal injury. 16. DO NOT DRIVE FASTENERS CLOSE to the edge of the workpiece. The workpiece is likely to split allowing the fastener to fly free or ricochet causing personal injury. 17. NEVER USE TOOL IN EXPLOSIVE ENVIRONMENT. Tool exhaust could cause fire or explosion. 18. DO NOT SMOKE or allow near any flame while installing or removing fuel cell, or when operating or servicing tool. a ADDITIONAL SAFETY RULES FOR FUEL CELLS 1. READ AND UNDERSTAND ALL INSTRUCTIONS before using or handling fuel cells. Failure to follow all instructions may result in explosion, fire, severe personal injury or property damage. 2. USE ONLY IN A WELL VENTILATED AREA. 3. OPERATOR AND ALL BYSTANDERS MUST WEAR approved safety glasses (complying with OSHA and ANSI Z87.1 requirements) when operating, loading fuel cell into tool, removing fuel cell or servicing tool. 4. DO NOT SMOKE or allow near any flame while installing or removing fuel cell, or when operating or servicing tool. 5. DO NOT STORE IN OR ALLOW PROLONGED EXPOSURE to sunlight or heat above 120°F (49°C) which may cause fuel cell to burst, releasing flammable gas. 6. DO NOT INCINERATE, CRUSH, PUNCTURE, ATTEMPT TO OPEN, RECLAIM OR RECYCLE fuel cell. Fuel cell is nonrefillable. 7. NEVER DISCHARGE CONTENTS TOWARD face, eyes or any bystander or when not installed in tool. 8. DO NOT INHALE CONTENTS. 9. KEEP OUT OF REACH OF CHILDREN. 10. NEVER CARRY OR STORE FUEL CELL IN AN ENCLOSED SPACE such as a car trunk, van or station wagon. A leak can result in a fire, explosion, asphyxiation or a toxic exposure. EMPLOYER’S RESPONSIBILITIES Employer must enforce compliance with the safety warnings and ail other instructions contained in this manual. Keep this manual available for use by all people assigned to use this tool. For personal safety and proper operation of this tool, read and follow all of these instructions carefully. Fig. 9 Fig. 10 Fig. 11 FiS'12 Æk A Fig. 13 Fig. 14 4 OPERATING INSTRUCTIONS FOREWORD Porter-Cable Model CMS200 is a professional, cordless stapler. It is designed to install medium crown (7/i6,! wide), 16 ga, wire staples of various lengths (from 1" to 2" long), see ACCESSORIES Listing in back of this manual. The tool may be used in any orientation. Ambient operating temperature range for the tool is 20° F to 120° F. Ambient temperatures beyond this range can cause the tool to operate intermittently, or to not operate. Extreme cold temperatures will slow the return of the tool from the compressed position to the extended position. Extremely cold fuel cells will not have enough vapor pressure to operate the tool. This tool is capable of firing two fasteners per second for short “bursts”, however you should not exceed two hundred (200) fasteners per fifteen minute period, or five hundred (500) fasteners per hour. Exceeding these rates may cause the tool to overheat resulting in severe damage to the tool. BREAK-IN PROCEDURE Your new Bammer is an internal combustion engine, and like a new truck engine it will perform better after a break-in period. At first the tool may be stiff during compression, and require a high push force, or extend very slowly in the inverted position. This is normal. No lubrication is required. As you use the Bammer for the first 200 or more fastenings, it will become easier to use, and extend quicker in the inverted position. Firing the first 200 fasteners in about 15 minutes will accelerate the break-in, and will not shorten the life of yo...
Ce manuel est également adapté pour les modèles :Clouteuses - BAMMER CMS200 (16.57 mb)