Log:
Évaluations - , GPA: ( )

Instructions ADC, Modèle AD-115ES

Fabricant : ADC
Taille : 1.31 mb
Nom Fichier : e9e4d98c-e084-49a4-abe8-6d096233aa58.pdf

Langue d'enseignement: en

Le document est chargé, s'il vous plaît patienter
Le document est chargé, s'il vous plaît patienter

Facilité d'utilisation


F. ELECTRICAL INFORMATION 1. Electrical Requirements It is your responsibility to have ALL electrical connections made by a properly licensed and competent electrician to ensure that the electrical installation is adequate and conforms to local and state regulations or codes. In the absence of such codes, ALL electrical connections, material, and workmanship must conform to the applicable requirements of the National Electrical Code ANSI/NFPA NO. 70-LATEST EDITION or in Canada, the Canadian Installation Codes CAN/CGA-B149.1-M91 (Natural Gas) or CAN/CGA-B149.2- M91 (Liquid Propane [L.P.] Gas) or LATEST EDITION. IMPORTANT: Failure to comply with these codes or ordinances, and the requirements stipulated in this manual, can result in personal injury or component failure. NOTE: Component failure due to improper installation will VOID THE WARRANTY. Each dryer should be connected to an independently protected branch circuit. The dryer must be connected with copper wire only. DO NOT use aluminum wire; it could create a fire hazard. The copper conductor wire and cable must be of proper ampacity and insulation, in accordance with electric codes for making ALL service connections. NOTE: The use of aluminum wire will VOID THE WARRANTY. 2. Electrical Service Specifications Reversing, 3o Motor (Gas and Steam) ELECTRICAL SERVICE SPECIFICATIONS (PER DRYER) IMPORTANT: NOTES: A. B. C. 208 VAC AND 230/240 VAC ARE NOT THE SAME. When ordering, specify exact voltage. When fuses are used they must be dual element, time delay, current limiting, class RK1 or RK5 ONLY. Calculate/determine correct fuse value, by applying either local and/or National Electrical Codes to listed appliance amp draw data. Circuit breakers are thermal-magnetic (industrial) motor curve type ONLY. For others, calculate/verify correct breaker size according to appliance amp draw rating and type of breaker used. Circuit breakers for 3-phase (3O) dryers must be 3-pole type. SERVICE VOLTAGE PHASE WIRE SERVICE APPROX. AMP DRAW MINIMUM WIRE SIZE FUSING CIRCUIT BREAKER Dual Element Time Delay 60 Hz 50 Hz 208 3o 3 14.5 — * 20 20 230 3o 3 — 16.0 * 25 25 240 3o 3 14.6 — * 20 20 380 3o 4** — 8.7 * 15 15 400 3o 4** — 8.5 * 15 15 416 3o 4** — 9.0 * 15 15 460-480 3o 3 7.8 — * 15 15 575 3o 3 5.8 — * 15 15 * AWG Stranded Wire Type; size wire as per National Electrical Code or local codes. (Motor lead wire is recommended.) 12/10/08 ** 3-Wire is available. IMPORTANT: The dryer must be connected to the electric supply shown on the data label. In the case of 208 VAC or 230/240 VAC, the supply voltage must match the electric service specifications of the data label exactly. WARNING: 208 VAC AND 230/240 VAC ARE NOT THE SAME. Any damage done to dryer components due to improper voltage connections will automatically VOID THE WARRANTY. IMPORTANT: 380, 400, and 416 volt dryers are built 4-wire only. Customer must contact the factory to special order 3-wire systems. NOTE: ADC reserves the right to make changes in specifications at any time without notice or obligation. American Dryer Corp. 113202-10 Reversing, 3o Motor (Electric) ELECTRICAL SERVICE SPECIFICATIONS (PER DRYER) IMPORTANT: NOTES: A. B. C. 208 VAC AND 240 VAC ARE NOT THE SAME. When ordering, specify exact voltage. When fuses are used they must be dual element, time delay, current limiting, class RK1 or RK5 ONLY. Calculate/determine correct fuse value, by applying either local and/or National Electrical Codes to listed appliance amp draw data. Circuit breakers are thermal-magnetic (industrial) type ONLY. For others, calculate/verify correct breaker size according to appliance amp draw rating and type of breaker used. Circuit breakers for 3-phase (3O) dryers must be 3-pole type. SERVICE VOLTAGE PHASE WIRE SERVICE APPROX. AMP DRAW MINIMUM WIRE SIZE FUSING CIRCUIT BREAKER Dual Element Time Delay 60 Hz 50 Hz 60 kW 208 3o 3 181 — * 250 250 230 3o 3 — 167 * 200 200 240 3o 3 159 — * 200 200 380 3o 4** — 100 * 125 125 400 3o 4** — 95 * 125 125 416 3o 4** — 92 * 125 125 460 3o 3 83 — * 125 125 480 3o 3 80 — * 100 100 575 3o 3 66 — * 100 100 72 kW 208 3o 3 214 — * 300 300 230 3o 3 — 197 * 250 250 240 3o 3 188 — * 250 250 380 3o 4** — 118 * 150 150 400 3o 4** — 112 * 150 150 416 3o 4** — 109 * 150 150 460 3o 3 98 — * 125 125 480 3o 3 94 — * 125 125 575 3o 3 78 — * 100 100 * AWG Stranded Wire Type; size wire as per National Electrical Code or local codes. (Motor lead wire is recommended.) 12/10/08 ** 3-Wire is available. IMPORTANT: The dryer must be connected to the electric supply shown on the data label. In the case of 208 VAC or 230/240 VAC, the supply voltage must match the electric service specifications of the data label exactly. WARNING: 208 VAC AND 230/240 VAC ARE NOT THE SAME. Any damage done to dryer components due to improper voltage connections will automatically VOID THE WARRANTY. IMPORTANT: 380, 400, and 416 volt dryers are built 4-wire only. Customer must contact the factory to special order 3-wire systems. NOTE: ADC re...

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories