|
Facilité d'utilisation
Add more water to the water pan. 4. Open the doors only as necessary to load and unload product. This helps to keep the interior conditions constant and saves energy. 3-5 303 Model HHC-990 3-5. CLEANING Daily: PROCEDURES 1. Turn all controls off and disconnect electrical supply. To avoid burns, allow the unit to cool before cleaning. 2. Open doors and remove all trays and racks from unit, and take them to a sink to thoroughly clean.Figure 3-3. Figure 3-3 3. Wipe interior and exterior of cabinet with damp cloth, soap and water. Do not use steel wool, other abrasive cleaners or cleaners/sanitizers containing chlorine, bromine, iodine or ammonia chemicals, as these will deteriorate the stainless steel, and glass material, and shorten the life of the unit. Do not use a water jet (pressure sprayer) to clean the unit, or component failure could result. 4. Wipe the control panel with a damp cloth. Do not splash water around controls. 5. Reinstall racks, and leave a door partially open over night to allow interior cabinet to thoroughly dry. 303 3-6 Model HHC-990 Figure 3-4 3-5. CLEANING Weekly: PROCEDURES (Continued) 1. Remove pans and racks from cabinet. 2. Open drain valve and empty water pan into a shallow pan or floor drain. See Figure 3-4. Hot water! Do not place your hand under the drain while draining the unit. Failure to follow this warning could result in severe burns and injury. 3. Remove concentration ring assembly from water pan. See Figure 3-5. Concentration ring could be hot! Allow to cool before removing, or burns could result. 4. Wash the concentration ring in a dishwasher or sink. 5. Liberally spray the water pan with a concentrated deliming agent and let stand for 10 minutes. To avoid damage to the unit, delime the unit weekly. 6. Scrub the pan with a brush and flush with water. 7. Return concentration ring assembly to the water pan. 8. Reinstall the racks and fill the water pan with water to the maximum water fill line. Unit is now ready for use. Remove the 2 screws securing the vented panel on the rear of the module and remove the panel, and clean vents. Using a cloth or sponge, clean the trough once a month. Figure 3-4 9. Monthly: 1. 2. 3-7 303 Model HHC-990 SECTION 4. PROGRAMMING This section explains the following programming functions. • Timer programming • Clock-set • Special programming 4-1. TIMER PROGRAMMING To enter the Program Mode: 1. Press and hold for 2 seconds, and “PROG TMRS” shows in display. 2. After 5 seconds, “ENTER CODE” shows in display. 3. Press , and “PUSH TIMER BUTTON “TO SELECT FOR PROGRAMMING,” followed by “USE UPAND DOWN TO CHANGE SELECTED TIMERS,” scrolls through the display. 4. Press the desired timer button (1-15). (More than one can be programmed at one time). 5. Press to change the selected timer settings. 6. Once timers are set, press and hold the , and new timer settings become active and normal operation is resumed. 4-2. CLOCK SET 1. Press and hold for 5 seconds, and LEVEL 2, then (Time-of-day, date, and day of the week) “CLOCK SET” shows in display. 2. After 5 seconds, “ENTER CODE” shows in display. 3. Press . 4. “CS-1, SET, HOUR”, and the time of day (with the hour flashing) shows in the display. 5. Press the to change the hours. 303 4-1 Model HHC-990 4-2. CLOCK SET 6. Press and “CS-2, SET, MINUTE” shows in the (Continued) display, with the minutes flashing. 7. Press to change the minutes. 8. Press and “CS-3, SET, MONTH” shows in the display, along with the date (month flashing). 9. Press to change the month. 10. Press and “CS-4, SET, DATE” shows in the display, with the date flashing. 11. Press to change the date. 12. Press and “CS-5, SET, YEAR” shows in the display, with the year flashing. 13. Press to change the year. 14. Press and hold to exit programming. 4-2 303 Model HHC-990 4-3. SPECIAL PROGRAMMING This mode allows you to program the following: SP-1 • Fahrenheit/celsius SP-2 • Lock/unlock SP-3 • Air temperature setpoint SP-4 • Humidity setpoint SP-5 • Proof air temperature SP-6 • Proof humidity setpoint SP-7 • Out of water tripp point SP-8 • Clean water pan setpoint SP-9 • System intialization SP-10 • Audio volume SP-11 • Audio tone SP-12 • Audio effects SP-13 • Language options SP-1 Fahrenheit/Celsius 1. Press and hold the until “LEVEL 2”, then “CLOCK SET” shows in the display. 2. Press again, then “SP PROG” shows in display. 3. After 5 seconds, “ENTER CODE” shows in display. 4. Press and “SP-1, TEMP, UNITS” and “oF”or “oC” shows in the display. 5. to change temperature units. Press the SP-2 Lock/Unlock 6. Press and “SP-2, LOCK/UNLOCK PROGRAMMING’ shows in display, along with either “LOCK” or “UNLOCK”. 7. Press to change lock the programming or unlock the programming. SP-3 Air Temperature Setpoint 8. Press and “SP-3, AIRTEMP SETPOINT,” and the preset cabinet temperature shows in display. 9. Press to change the air temperature setpoint, 140o F (60o C) minimum, 210o F (99o C) maximum. 303 4-3 Model HHC-990 4-3. SPECIAL PROGRAMMING (Continued) SP-4 Humid...
Ce manuel est également adapté pour les modèles :Séchoirs - HHC-990 (335.55 kb)
Séchoirs - HHC-992 (335.55 kb)
Séchoirs - HHC-993 (335.55 kb)
Séchoirs - HHC-997 (335.55 kb)