|
Facilité d'utilisation
! ! Mobile home installations require: Metal exhaust system hardware, which is available for purchase from your local Sears store or Sears Service Center. Mobile Home Installation Kit Part Number 346764. See "Tools and Parts" section for ordering information. Special provisions must be made in mobile homes to introduce outside air into the dryer. The opening (such as a nearby window) should be at least twice as large as the dryer exhaust opening. Electrical Shock Hazard Plug into a grounded 3 prong outlet. Do not remove ground prong. Do not use an adapter. Do not use an extension cord. Failure to follow these instructions can result in death, fire, or electrical shock. 120 Volt, 60 Hz., AC only, 15-or 20-amp fused electrical supply is required. A time-delay fuse or circuit breaker is recommended. It is also recommended that a separate circuit serving only this dryer be provided. GROUNDING iNSTRUCTiONS [] For a grounded, cord-connected dryer: This dryer must be grounded. In the event of malfunction or breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance for electric current. This dryer is equipped with a cord having an equipment- grounding conductor and a grounding plug. The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances. WARNING: improper connection of the equipment- grounding conductor can result in a risk of electric shock. Check with a qualified electrician or service representative or personnel if you are in doubt as to whether the dryer is properly grounded. Do not modify the plug provided with the dryer: if it will not fit the outlet, have a proper outlet installed by a qualified electrician. SAVE THESE INSTRUCTIONS Explosion Hazard Use a new CSA International approved gas supply line. Install a shut=off valve. Securely tighten all gas connections. if connected to LP, have a qualified person make sure gas pressure does not exceed 13" (33 cm) water column. Examples of a qualified person include: licensed heating personnel, authorized gas company personnel, and authorized service personnel. Failure to de so can result in death, explosion, or fire. Gas Type Natural gas: This dryer is equipped for use with Natural gas. It is design- certified by CSA International for LP (propane or butane) gases with appropriate conversion. • Your dryer must have the correct burner for the type of gas in your home. Burner information is located on the rating plate in the door well of your dryer. If this information does not agree with the type of gas available, contact your local Sears store or Sears Service Center. LP gas conversion: Conversion must be made by a qualified technician. No attempt shall be made to convert the appliance from the gas specified on the model/serial rating plate for use with a different gas without consulting your gas company. Gas supply line • Must include r/s" NPT minimum plugged tapping accessible for test gauge connection, immediately upstream of the gas connection to the dryer (see illustration). • V2" IPS pipe is recommended. • %" approved aluminum or copper tubing is acceptable for lengths under 20 ft (6.1 m) if local codes and gas supplier permit. • If you are using Natural gas, do not use copper tubing. • %" flare x %" NPT adapter fitting between dryer pipe and %" approved tubing. • Lengths over 20 ft (6.1 m) should use larger tubing and a different size adapter fitting. • If your dryer has been converted to use LP gas, %" LP compatible copper tubing can be used. If the total length of the supply line is more than 20 ft (6.1 m), use larger pipe. NOTE: Pipe-joint compounds that resist the action of LP gas must be used. Do not use TEFLON _t tape. • Must include a shutoff valve: An individual manual shutoff valve must be installed in accordance with the B149.1, Natural Gas and Propane Installation Code. It is recommended that an individual manual shutoff valve be installed within six (6) feet (1.8 m) of the dryer and the location be easy to reach for opening and closing. A CE B D A. %" flexible gas connector B. _" pipe to flare adapter fitting C. _" NPTminimum plugged tapping D. _2"NPTgas supply line E.Gas shutoff valve Gas supply connection requirements • Use an elbow and a %" flare x %" NPT adapter fitting between the flexible gas connector and the dryer gas pipe, as needed to avoid kinking. • Use only pipe-joint compound. Do not use TEFLON _ tape. • This dryer must be connected to the gas supply line with a listed flexible gas connector that complies with the standard for connectors for gas appliances, CSA 6.10. Burner input requirements Elevations above 10,000 ft (3,048 m): • When installed above 10,000 ft (3,048 m) a 4% reduction of the burner Btu rating shown on the model/serial number plate is required for each 1,000 ft (305 m) increase in elevation. Gas supply pressure testing • The dryer must be disconnected from the gas supply piping system dur...
Ce manuel est également adapté pour les modèles :Séchoirs - 9757 (3.55 mb)
Séchoirs - 9758 (3.55 mb)